Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 7F.21.9.024.1020.0 is an extended product reference associated with the Finder 7F.21 reverse-flow exhaust filter fan range. The corresponding base model 7F.21.9.024.1020 is a Size 1, 24 V DC fan with 24 m³/h nominal free-air volume, 3.6 W rated power, 120 x 120 mm front housing and a 92 x 92 mm nominal panel cut-out. The significance of the additional .0 suffix should be confirmed before ordering.
£50.50
The Finder 7F.21.9.024.1020.0 is a compact 24 V DC reverse-flow exhaust filter fan from the Finder 7F Series, designed to help manage heat inside industrial electrical enclosures, automation cabinets and control panels.
The corresponding Finder base model, 7F.21.9.024.1020, is a Size 1 exhaust filter fan with a nominal free-air volume of 24 m³/h and a rated power consumption of 3.6 W. The additional .0 suffix is retained in this listing to identify the requested product reference; its precise ordering significance should be confirmed against the supplier's documentation.
Unlike a standard intake filter fan, the Finder 7F.21 reverse-flow design actively extracts warm air from an electrical cabinet. This supports an effective ventilation path when paired with a suitable air inlet and helps reduce heat accumulation around electrical and electronic components.
The compact 120 × 120 mm front housing, 92 × 92 mm nominal panel cut-out and replaceable filter element make this product suitable for electrical engineers, control panel builders, OEM machine manufacturers and industrial maintenance teams.
The following technical characteristics relate to the corresponding published Finder 7F.21.9.024.1020 base model. The additional .0 suffix should be verified before ordering where exact variant specifications are essential.
The Finder 7F.21.9.024.1020.0 is intended to provide active air extraction from an electrical enclosure.
When the fan operates, its integrated DC motor drives airflow from inside the cabinet towards the external ventilation opening.
This helps remove warm air produced by components such as power supplies, relays, contactors, controllers and electronic modules.
Replacement air enters through a suitable inlet, creating a ventilation path through the enclosure.
The corresponding base model has a nominal 24 m³/h free-air volume. Actual airflow through an installed cabinet depends on the enclosure design, filter condition, inlet resistance and internal obstructions.
The fan should be selected according to the heat generated inside the cabinet and the required operating temperature of the installed electrical equipment.
The Finder 7F.21 range is designed for reverse-flow operation, while standard 7F.20 filter fans are generally used for air intake.
An intake fan introduces external air into the enclosure and allows warm air to escape through an outlet.
A reverse-flow exhaust fan actively removes air from the enclosure, with replacement air entering through a separate opening.
The preferred arrangement depends on the enclosure layout, ambient dust levels, required airflow path and environmental protection requirements.
For applications where airborne contamination is a concern, the complete ventilation design should be assessed to ensure suitable inlet filtration and cabinet protection.
The Finder 7F.21.9.024.1020 base configuration uses a nominal 24 V DC electrical supply.
This makes it suitable for many industrial control panels that already incorporate a regulated 24 V DC power supply.
With a rated power consumption of 3.6 W, the fan can provide forced ventilation with a relatively low electrical demand.
The available power supply capacity, wiring polarity and protective arrangements should be checked before installation.
Important: The fan must not be connected directly to a 120 V AC or 230 V AC supply.
The Finder Size 1 filter fan format is suitable for electrical cabinets where installation space is limited.
The corresponding base model has a 120 × 120 mm front housing and an approximate overall depth of 50.4 mm.
The nominal panel cut-out is 92 × 92 mm.
The unit should be installed in a suitable enclosure wall or panel in accordance with Finder's mounting instructions.
For effective thermal management, the exhaust fan should be positioned to encourage airflow across the cabinet's heat-generating components.
Before preparing the panel opening, installers should verify the exact dimensions and mounting requirements against the product supplied.
The corresponding Finder 7F.21 base model has an IP54 ingress protection rating when correctly installed.
IP54 indicates protection against harmful dust ingress and splashing water under the relevant test conditions.
The rating of the completed electrical enclosure depends on the installation of the fan, the sealing of the panel opening and the protection ratings of other cabinet components.
IP54 does not mean that the fan is suitable for immersion, high-pressure washing or unrestricted outdoor weather exposure.
The Finder 7F.21 filter fan incorporates a replaceable filter element.
Over time, airborne dust can accumulate within the filter and increase resistance to airflow.
Regular inspection and replacement help preserve ventilation performance and reduce the likelihood of excessive cabinet temperatures caused by restricted airflow.
The correct replacement filter should be selected according to Finder's Size 1 accessory information and the exact supplied fan assembly.
Maintenance intervals should reflect the surrounding environment, operating hours and airborne contamination levels.
The Finder 7F.21.9.024.1020.0 can be incorporated into a suitable temperature-controlled ventilation system.
A compatible thermostat or controller can switch the fan according to the cabinet's internal temperature.
This allows forced ventilation to operate when required rather than continuously, depending on the application.
The thermostat or switching device must be rated for the fan's DC supply voltage and motor load.
The temperature setpoint should be selected according to the operating limits of the equipment installed inside the enclosure.
Tick the specs you need, then view products that match.
| Cut-Out Size (mm) | 92 × 92 mm |
|---|
The Finder 7F.21.9.024.1020.0 is an extended product reference associated with the Finder 7F.21 reverse-flow exhaust filter fan range. The corresponding base model is a Size 1, 24 V DC fan with a nominal free-air volume of 24 m³/h.
The exact significance of the final .0 has not been independently confirmed. The extended part number should be checked against Finder or the supplier's ordering information when exact variant identification is required.
The corresponding base model operates from a nominal 24 V DC supply.
The corresponding base model has a nominal 24 m³/h free-air volume, equivalent to approximately 14.1 CFM.
It is a reverse-flow exhaust fan, designed to remove warm air from an electrical enclosure.
The corresponding base model has a rated power consumption of 3.6 W.
It corresponds to a Size 1 fan assembly with a 120 × 120 mm front housing and an approximate depth of 50.4 mm.
The Finder Size 1 configuration uses a nominal 92 × 92 mm panel cut-out. The installation drawing should be checked before cutting the enclosure.
The corresponding base model has an IP54 protection rating when correctly installed.
Yes. It is an electrically powered exhaust filter fan, not a passive ventilation grille.
Yes. The Finder 7F Series filter fan design includes a replaceable filter element. The correct replacement should be selected for the exact supplied Size 1 assembly.
Yes. It can be switched using a suitable thermostat or controller rated for the 24 V DC fan motor load.
No. The corresponding base model requires 24 V DC and must not be connected directly to nominal 230 V AC UK mains.
The 7F.20 range is generally used for intake ventilation, while the 7F.21 range provides reverse-flow exhaust ventilation.
The Finder 7F.21.9.024.1020.0 is listed as an extended reference for a compact Finder Size 1 reverse-flow exhaust filter fan. The corresponding base model combines 24 V DC operation, 24 m³/h nominal free-air volume and 3.6 W rated power to provide active air extraction for suitable industrial electrical enclosures. Confirm the additional .0 suffix against the supplier's ordering information before purchasing where exact variant specifications are required.
We use cookies