Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 07E.16 is a protective terminal cover for compatible Finder 7E Series single-phase and three-phase electricity meters, providing mechanical terminal coverage and supporting tamper-evident lead sealing.
£3.62
The Finder 07E.16 is a dedicated protective terminal cover for compatible Finder 7E Series electricity meters. Designed to provide physical coverage for electrical terminal connections, this genuine Finder accessory supports tamper-evident lead sealing in commercial, industrial and residential energy monitoring installations.
The Finder 07E.16 is compatible with several models in the Finder 7E Series energy meter range, including 7E.12, 7E.16 and 7E.36. Finder documentation also identifies compatibility with selected 7E.46 and 7E.56 meters. This makes it a versatile accessory for single-phase and three-phase electricity metering installations where controlled access to terminal connections is required.
The number of covers required depends on the meter configuration. For Finder 7E.12 and 7E.16 single-phase meters, two terminal covers are required for a complete tamper-evident sealing arrangement. For compatible 7E.36, 7E.46 and 7E.56 three-phase meters, four covers are required. The 07E.16 is a passive mechanical accessory and does not perform electrical measurement, switching or circuit protection.
The Finder 07E.16 is designed to complement compatible Finder 7E Series electricity meters by providing dedicated coverage for their electrical terminal connections. Energy meters are commonly installed in electrical distribution boards and monitoring cabinets to record energy consumption for buildings, machinery, tenants and individual electrical circuits.
In these installations, access to the terminal connections may need to be controlled to discourage interference with the metering arrangement. The 07E.16 terminal cover provides a manufacturer-specified physical barrier and supports the use of a tamper-evident lead seal. A correctly fitted seal can make interference with the covered terminal area more apparent during inspection.
The accessory supports several meter configurations. For compatible Finder 7E.12 and 7E.16 single-phase meters, Finder specifies two covers for the complete sealing arrangement. For compatible 7E.36, 7E.46 and 7E.56 three-phase meters, four covers are specified. This distinction is important when ordering accessories for an installation because a single cover does not constitute a complete sealed meter arrangement.
The Finder 07E.16 is a mechanical accessory rather than an electrical safety device. It does not measure energy consumption, interrupt electrical faults or provide isolation. Its purpose is to cover the designated terminals of the compatible meter and facilitate the specified sealing arrangement.
For a reliable installation, the complete meter model should be checked against Finder's technical documentation. Electrical connections must be safely isolated before installation or maintenance, and the cover should be fitted in accordance with the manufacturer's instructions. The complete assembly must also comply with the applicable electrical installation and enclosure requirements.
| Manufacturer | Finder |
|---|---|
| Product reference | 07E.16 |
| Manufacturer part number | 07E.16 |
| Alternative ordering reference | 07E16 |
| Product type | Electricity meter terminal cover |
| Accessory category | Energy meter accessories |
| Associated product series | Finder 7E Series |
| Primary function | Mechanical terminal coverage and tamper-evident sealing |
| Compatible meter type | Finder 7E.36 |
| Additional documented compatibility | Selected Finder 7E.46 and 7E.56 meters |
| Single-phase meter sealing requirement | 2 covers for compatible 7E.12 and 7E.16 meters |
| Three-phase meter sealing requirement | 4 covers for compatible 7E.36, 7E.46 and 7E.56 meters |
| Sealing arrangement | Tamper-evident lead seal provision |
| Associated meter mounting | 35 mm DIN rail, EN 60715 |
| Associated meter configurations | Single-phase and three-phase |
| Electrical measurement function | None |
| Integrated switching contacts | None |
| Independent power supply required | No |
| Meter included | No |
| Sealing hardware included | Not confirmed; check the supplied package contents |
| RoHS compliance | Yes |
| Country of origin | Italy |
| EAN | 8012823318868 |
The Finder 07E.16 is a protective terminal cover designed for compatible Finder 7E Series electricity meters. It provides mechanical coverage for the meter's terminal connections and supports tamper-evident lead sealing.
The Finder 07E.16 is compatible with Finder 7E.12, 7E.16 and 7E.36 energy meters. Finder documentation also lists selected 7E.46 and 7E.56 meters. Compatibility should be confirmed against the complete meter model before installation.
Finder specifies two 07E.16 covers for compatible 7E.12 and 7E.16 single-phase meters. For compatible 7E.36, 7E.46 and 7E.56 three-phase meters, four covers are required for a complete tamper-evident lead-sealed arrangement.
The Finder 07E.13 is designed for the compact 7E.13 electricity meter, while the Finder 07E.16 is designed for compatible 7E.12, 7E.16 and 7E.36 meters, as well as selected 7E.46 and 7E.56 models. The accessories should be selected according to the exact meter reference.
No. The Finder 07E.16 is a terminal cover accessory only. The electricity meter is supplied separately, and the number of covers required depends on the compatible meter configuration.
No. The Finder 07E.16 is a passive mechanical accessory. It provides physical terminal coverage but does not replace electrical isolation, circuit protection, safe working procedures or the protective enclosure requirements of the installation.
Finder 7E Series energy metering accessories support professional electrical monitoring installations by providing dedicated terminal coverage and tamper-evident sealing options. The Finder 07E.16 offers compatibility with selected single-phase and three-phase Finder electricity meters, making it a practical accessory for commercial, industrial and building energy management systems.