Finder 072.51 - 72 Series Level control relays - Accessory

Finder 072.51 – 72 Series Level control relays – Accessory

Finder 072.51 – 72 Series Level control relays – Accessory.

SKU: 072.51Alt SKU: 07251MPN: 072.51
Price
List Price £43.11 ex VAT
Your Price (ex VAT) Save 30%
£30.18 30% OFF
You save £12.93 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £30.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£30.18

Why Choose the Finder 072.51 Conductive Liquid Level Sensor?

The Finder 072.51 is a conductive liquid level sensing electrode designed for use with compatible Finder 72 Series liquid level monitoring relays. It provides a practical solution for detecting the presence of electrically conductive liquids in tanks, reservoirs, sumps and industrial water management systems.

Designed for integration into an electrical liquid level control system, the Finder 072.51 works as a sensing component rather than a standalone switching device. When connected to a compatible level monitoring relay, the electrode enables the control system to detect liquid contact and respond according to the configured filling, emptying or level monitoring function.

The Finder 072.51 conductive level probe is suitable for applications involving water and other compatible conductive liquids. Its straightforward operating principle makes it a useful accessory for automated pump control, water storage monitoring and industrial liquid management installations.

Key Advantages

  • Designed for use with compatible Finder 72 Series liquid level control relays.
  • Enables reliable detection of electrically conductive liquids.
  • Supports automatic filling and emptying applications when used with a suitable controller.
  • Simple electrode-based sensing principle.
  • Suitable for water tanks, reservoirs, sumps and liquid storage installations.
  • Provides a practical sensing point for automated pump control systems.
  • Can be incorporated into multi-electrode liquid level monitoring arrangements.
  • Does not require a separate power supply at the sensing electrode.
  • Suitable for industrial and building services applications involving compatible conductive liquids.

Key Features

  • Finder 072.51 conductive liquid level electrode.
  • Accessory for compatible Finder liquid level monitoring relays.
  • Conductivity-based liquid detection.
  • Designed for sensing the presence or absence of conductive liquid at an installed level.
  • Supports minimum and maximum liquid level monitoring configurations.
  • Suitable for automatic pump filling and emptying control systems.
  • Passive sensing component without an internal switching relay.
  • Connects to a compatible monitoring relay through an electrode sensing circuit.
  • Suitable for use with additional sensing electrodes where required by the control arrangement.
  • Designed for integration into electrical liquid level monitoring installations.

How Conductive Liquid Level Monitoring Works

The Finder 072.51 operates as part of a conductivity-based liquid level detection system. A compatible Finder monitoring relay applies a sensing signal through the electrode circuit. When conductive liquid reaches the installed electrode, the liquid provides an electrical path that the monitoring relay can detect.

Depending on the relay configuration, this detected condition can be used to control the filling or emptying of a tank, monitor a minimum or maximum liquid level, or initiate an alarm through the associated control circuit. Multiple electrodes may be used to establish different sensing points, subject to the requirements of the selected monitoring relay.

The electrode itself does not directly switch a pump or electrical load. Switching is performed by the associated level control relay and any additional control equipment. Correct operation depends on the liquid's conductivity, electrode positioning, wiring arrangement and compatibility with the selected monitoring relay. The Finder 072.51 should not be used for non-conductive liquids such as oils unless the complete sensing system has been specifically designed for that application.

Typical Applications

  • Automatic water tank filling systems.
  • Reservoir liquid level monitoring.
  • Sump pump control installations.
  • Water storage tank level detection.
  • Industrial process water management.
  • Building services water control systems.
  • Minimum and maximum liquid level monitoring.
  • Water transfer and pump automation systems.
  • Liquid presence detection in compatible conductive media.
  • Electrical control panels incorporating Finder 72 Series monitoring relays.

Technical Specifications

Manufacturer Finder
Part number 072.51
Product category Liquid level control accessories
Product type Conductive liquid level sensing electrode
Associated product range Finder 72 Series
Sensing principle Electrical conductivity
Primary function Detection of conductive liquid at the electrode position
Compatible medium Electrically conductive liquids
Typical monitored liquid Water
System application Liquid level monitoring and pump control
Control arrangement Connection to a compatible external liquid level monitoring relay
Switching contacts None; sensing accessory only
Standalone control capability Requires a compatible level monitoring relay
Typical installation Liquid storage tanks, reservoirs and sumps

Frequently Asked Questions

What is the Finder 072.51 used for?

The Finder 072.51 is a conductive liquid level sensing electrode used with compatible Finder liquid level monitoring relays. It detects the presence of conductive liquid at a selected position in a tank, reservoir or sump.

Is the Finder 072.51 a complete liquid level controller?

No. The Finder 072.51 is a sensing electrode, not a complete controller. It must be connected to a compatible liquid level monitoring relay, which interprets the electrode signal and operates the associated control contacts.

Can the Finder 072.51 be used for automatic pump control?

Yes. When connected to a compatible Finder level monitoring relay and correctly configured control circuit, the electrode can provide liquid level information for automatic pump filling or emptying operations.

What liquids can the Finder 072.51 detect?

The electrode is intended for electrically conductive liquids, such as water with sufficient conductivity for the monitoring system. It is not suitable for detecting non-conductive liquids using the standard conductivity sensing principle.

Which Finder relays can be used with the 072.51 electrode?

The Finder 072.51 is intended for compatible Finder 72 Series liquid level monitoring relays. The specific relay model, wiring arrangement and permitted electrode configuration should be checked against the relevant Finder technical documentation before installation.

Trusted by Industrial Automation and Water Management Professionals

Finder liquid level monitoring products provide practical solutions for automated water management, pump control and industrial process monitoring. The Finder 072.51 conductive sensing electrode offers a straightforward way to detect liquid levels when incorporated into a correctly designed and compatible Finder monitoring system.