Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 072.503 is an electrode separator designed for use with the Finder 072.53 three-pole electrode holder in Series 72 liquid level monitoring systems. It helps maintain spacing between adjacent electrode rods and prevents them from touching where longer electrodes may sway. Suitable for compatible conductive liquid monitoring assemblies using Finder 072.500 electrodes and 072.501 connectors.
£1.56
The Finder 072.503 is a purpose-designed electrode separator for Finder Series 72 liquid level monitoring systems. Specifically intended for use with the Finder 072.53 three-pole electrode holder, this compact accessory helps maintain the correct separation between electrode rods installed in tanks, wells and other conductive liquid monitoring applications.
When multiple electrodes are installed together, particularly in deeper tanks where longer electrode assemblies are required, the rods may move or sway. The Finder 072.503 electrode separator helps prevent adjacent electrodes from touching, supporting the correct physical arrangement of the sensing probes and reducing the risk of unintended electrical contact between them.
The separator is especially useful in installations incorporating Finder 072.500 stainless steel electrodes and Finder 072.501 inter-electrode connectors. These components can be used together to construct electrode assemblies of the required length, while the 072.503 provides additional spacing support where appropriate.
Identified by manufacturer part number 072.503, this genuine Finder accessory is suitable for professional liquid level control installations associated with Finder Series 72 monitoring relays, including the 72.01 and 72.11. It is a passive mechanical component and does not independently detect liquid levels or operate electrical switching circuits.
The main purpose of the Finder 072.503 electrode separator is to help maintain physical separation between multiple electrode rods used in a conductive liquid level monitoring system.
Conductive liquid monitoring installations often use two or three electrodes positioned at different heights within a tank or well. These electrodes are connected to a suitable monitoring relay, which detects electrical conductivity through the liquid and responds according to its configured operating function.
Where electrodes are relatively short, their position may be adequately controlled by the electrode holder and the mechanical rigidity of the rods. However, in deeper installations, longer electrode assemblies may be required to reach the desired sensing positions.
Longer electrodes can be more susceptible to movement. Liquid flow, vibration, turbulence or the natural flexibility of the assembled rods may cause the electrodes to sway.
If adjacent electrodes touch, an unintended electrical connection may occur between them. This can interfere with the intended sensing arrangement and may cause incorrect liquid level detection or unexpected monitoring relay operation.
The Finder 072.503 helps address this issue by maintaining spacing between the electrode rods. It is therefore an important mechanical accessory in suitable multi-electrode installations, particularly where extended probes are used.
Finder identifies the 072.503 electrode separator as an accessory for the Finder 072.53 three-pole electrode holder.
The Finder 072.53 is designed to support a three-electrode arrangement in suitable liquid level monitoring applications. It provides the mounting and connection arrangement for multiple sensing electrodes, allowing their positions to be established within a tank or well.
The 072.503 complements this arrangement by helping keep the electrode rods separated further along their length.
This distinction is important because the 072.53 electrode holder and the 072.503 separator perform different mechanical functions. The holder provides the main mounting arrangement, while the separator helps maintain spacing between the installed electrode rods.
The Finder 072.503 should not be assumed to fit every electrode holder or sensing probe arrangement. Its documented compatibility is specifically associated with the Finder 072.53 three-pole electrode holder.
Finder's Series 72 accessories include the 072.500 stainless steel electrode and 072.501 inter-electrode connector.
The 072.500 is an electrode rod with an M4 threaded connection. Finder's current Series 72 documentation specifies a nominal electrode length of 475 mm, although some older documentation describes a 500 mm version.
The Finder 072.501 connector allows multiple compatible electrode rods to be joined together to create a longer sensing assembly. This is useful when an electrode must reach a specific liquid level within a deeper tank.
As the overall electrode length increases, maintaining suitable separation between neighbouring rods becomes increasingly important. The Finder 072.503 separator provides additional mechanical support by helping prevent the electrodes from coming into contact with one another.
The number and positioning of separators required for an installation should be determined according to the electrode length, tank conditions and Finder's installation guidance.
The separator does not join electrode rods end to end. That function is performed by the Finder 072.501 inter-electrode connector. The 072.503 is used to maintain separation between adjacent electrodes.
Finder Series 72 monitoring relays are designed for liquid level control applications involving electrically conductive liquids.
A typical system uses sensing electrodes positioned within a tank or vessel. The monitoring relay detects the electrical condition between the electrodes and controls its output according to the selected operating mode.
Depending on the system configuration, this can support applications such as automatic tank filling, tank emptying, high-level monitoring and low-level control.
The Finder 072.503 electrode separator does not perform the sensing function itself. Instead, it helps preserve the intended physical arrangement of the electrodes that form part of the sensing circuit.
For example, a three-electrode arrangement may use separate electrodes for common reference, minimum level and maximum level detection. Maintaining appropriate spacing between the electrodes helps prevent unwanted direct contact that could compromise the intended control arrangement.
This is particularly relevant where the liquid is moving, where a tank is relatively deep or where extended electrode assemblies are installed.
The overall suitability of a conductive liquid level monitoring system depends on the liquid conductivity, electrode configuration, monitoring relay settings, installation environment and associated control equipment.
| Finder Part Number | Accessory Type | Primary Function |
|---|---|---|
| 072.53 | Three-pole electrode holder | Supports a three-electrode sensing arrangement |
| 072.500 | Stainless steel electrode | Provides the conductive sensing rod |
| 072.501 | Inter-electrode connector | Joins compatible electrode rods to extend probe length |
| 072.503 | Electrode separator | Maintains spacing between adjacent electrode rods |
| 072.51 | Electrode holder | Supports a compatible electrode arrangement |
The Finder 072.503 is the correct accessory when the requirement is to maintain separation between electrodes in a compatible three-pole assembly. It should not be confused with the 072.501 connector, which is designed to join electrode sections together.
Before installing the Finder 072.503, confirm that the electrode assembly uses the compatible Finder 072.53 three-pole electrode holder and suitable electrode rods.
The separator should be positioned in accordance with Finder's installation instructions so that the electrodes remain correctly spaced without introducing excessive mechanical stress.
The required number of separators depends on the design of the complete electrode assembly. Longer rods, liquid turbulence and installation conditions may influence the amount of mechanical support required.
The electrodes should be checked for correct alignment and secure connections, particularly where multiple Finder 072.500 rods are joined using 072.501 connectors.
During maintenance, the separator should be inspected for damage, displacement or deterioration. Any damaged accessory should be replaced with a suitable manufacturer-approved component.
The complete liquid level monitoring system should also be checked to ensure that electrode spacing, wiring and monitoring relay settings remain appropriate for the application.
All installation and maintenance work should be carried out by appropriately qualified personnel following the relevant electrical safety procedures and manufacturer's documentation.
| Brand | Finder |
|---|---|
| Manufacturer part number (MPN) | 072.503 |
| Product code | 072.503 |
| Product description | Electrode separator for Series 72 level monitoring systems |
| Product category | Liquid level monitoring accessories |
| Product family | Finder Series 72 |
| Accessory type | Electrode separator |
| Primary compatibility | Finder 072.53 three-pole electrode holder |
| Associated electrode type | Finder 072.500 |
| Associated electrode connector | Finder 072.501 |
| Associated monitoring relay | Finder 72.01 |
| Additional associated monitoring relay | Finder 72.11 |
| Mechanical function | Separation and positioning of electrode rods |
| Application | Multiple-electrode liquid level sensing assemblies |
| Independent sensing function | None |
| Electrical switching contacts | None |
| Coil voltage | Not applicable |
| Electrical supply | Not required |
| Installation environment | Suitable liquid level monitoring assemblies |
| Typical monitored medium | Conductive liquids |
| Typical installation | Tanks, wells and reservoirs |
| RoHS status | RoHS compliant |
| REACH status | Listed as REACH unaffected by a major component distributor |
| Country of origin | Italy |
The Finder 072.503 is an electrode separator designed for use with the Finder 072.53 three-pole electrode holder in compatible Series 72 liquid level monitoring systems.
The Finder 072.503 helps maintain separation between electrode rods, preventing adjacent electrodes from touching where they may sway due to their length or installation conditions.
The Finder 072.503 is specifically identified by Finder as an electrode separator for the Finder 072.53 three-pole electrode holder.
An electrode separator helps prevent adjacent sensing rods from touching. This is particularly important in longer electrode assemblies where movement or swaying could otherwise cause unintended electrical contact.
Yes. The Finder 072.503 can be used as part of a compatible three-pole electrode assembly incorporating Finder 072.500 stainless steel electrode rods.
The Finder 072.501 is an M4 threaded connector used to join electrode rods end to end. The Finder 072.503 is a separator used to maintain spacing between adjacent electrode rods.
No. The Finder 072.503 is a passive mechanical accessory. It does not independently detect liquid levels. The sensing function is performed by the electrodes and compatible liquid level monitoring relay.
The Finder 072.503 forms part of the Finder Series 72 liquid level monitoring accessory range, associated with electrode systems used alongside compatible monitoring relays such as the Finder 72.01 and 72.11.
Yes. The Finder 072.503 is particularly useful in suitable deeper tank installations where extended electrode rods may sway and require additional separation support.
No. The Finder 072.503 is a mechanical electrode spacing accessory and does not require an independent electrical supply.
The number required depends on the length of the electrode assembly, the installation conditions and the manufacturer's recommendations. The complete electrode arrangement should be assessed before installation.
The manufacturer part number is 072.503. This identifies the genuine Finder electrode separator intended for the compatible 072.53 three-pole electrode holder.
Finder manufactures electrical relays, monitoring devices and industrial automation components for professional applications. The Finder 072.503 electrode separator provides electrical contractors, panel builders and maintenance engineers with a dedicated solution for maintaining appropriate electrode spacing in compatible Series 72 conductive liquid level monitoring installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.