VX8618.822 Rittal EMC GLAND PLAW: 1000 MM

VX8618.822 Rittal EMC GLAND PLAW: 1000 MM

Rittal VX8618.822 zinc-plated sheet steel EMC gland plate for 1000 mm wide VX enclosures provides combined low-resistance shield contacting and cable fastening for shielded cables up to 20 mm diameter.

SKU: VX8618.822Alt SKU: 8618822MPN: VX8618.822
Price
List Price £109.79 ex VAT
Your Price (ex VAT) Save 15%
£93.32 15% OFF
You save £16.47 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £93.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£93.32

Why Choose the Rittal VX8618.822 EMC Gland Plate?

The Rittal VX8618.822 is a specialist EMC gland plate for Rittal VX enclosures, designed to provide effective cable shield contacting and secure cable fastening for electromagnetic compatibility applications. Suitable for shielded cables with a maximum diameter of 20 mm, it creates a low-resistance electrical connection between the cable shield and the gland plate.

Designed for 1000 mm wide VX enclosures, the VX8618.822 can be used with enclosure depths of 400 mm, 500 mm, 600 mm and 800 mm in conjunction with the standard gland plates. The combined EMC contacting and cable retention arrangement helps simplify shield termination while providing a mechanically secure cable entry solution.

Manufactured from robust zinc-plated sheet steel, the VX8618.822 is supplied as a complete assembly comprising one gland plate with T-head punching, one sliding gland plate and two EMC seals. The product is intended for one enclosure half, allowing EMC cable entry to be integrated into compatible VX installations without requiring a completely separate cable management system.

Key Advantages

  • Provides combined EMC cable shield contacting and cable fastening.
  • Creates a low-resistance connection between cable shields and the gland plate.
  • Suitable for shielded cables up to 20 mm diameter.
  • Designed for 1000 mm wide Rittal VX enclosures.
  • Compatible with enclosure depths of 400 mm, 500 mm, 600 mm and 800 mm.
  • Integrates with the standard VX gland plates.
  • Robust zinc-plated sheet steel construction.
  • Supplied with the gland plate, sliding gland plate and EMC seals required for one enclosure half.

Key Features

  • Rittal VX EMC gland plate.
  • Designed for 1000 mm enclosure width.
  • Compatible with VX enclosure systems.
  • Supports shielded cables up to 20 mm diameter.
  • Combined EMC contacting and mechanical cable fastening.
  • Low-resistance contact between cable shield and gland plate.
  • Suitable for 400–800 mm enclosure depths.
  • Sheet steel construction.
  • Zinc-plated surface finish.
  • Includes gland plate with T-head punching.
  • Includes sliding gland plate.
  • Includes 2 EMC seals.
  • Designed for one enclosure half.

Effective EMC Cable Shield Contacting for VX Enclosures

Reliable shield termination is important in electrical and automation installations where electromagnetic interference can affect signal integrity or equipment operation. The Rittal VX8618.822 combines EMC contacting with mechanical cable fastening, providing a low-resistance conductive path between the shield of each compatible cable and the enclosure gland plate.

The gland plate is designed for 1000 mm wide VX enclosures across multiple enclosure depths and works together with the standard gland plates. Its sliding plate arrangement and supplied EMC seals provide a practical cable-entry solution for panel builders and system integrators configuring drives, automation equipment, control systems and other EMC-sensitive installations.

Typical Applications

  • Shielded cable entry into Rittal VX enclosures.
  • Variable speed drive and motor control installations.
  • Industrial automation and PLC systems.
  • EMC-sensitive electrical control cabinets.
  • Instrumentation and process control systems.
  • Industrial communication and signal cabling.
  • Machine control and production equipment.
  • Electrical installations requiring low-resistance cable shield termination.
  • OEM panel building and system integration.

Technical Specifications

Tick the specs you need, then view products that match.

Material Steel
Accessory Type Gland Plate
Manufacturer Rittal
Series VX Accessories
Model VX8618.822
Article number VX 8618.822
Alternative SKU 8618822
Product type EMC gland plate
Enclosure type Accessories
Compatible enclosure system VX
Suitable enclosure width 1000 mm
Suitable enclosure depths 400 mm / 500 mm / 600 mm / 800 mm
Maximum shielded cable diameter 20 mm
Surface finish Zinc-plated
EMC function Low-resistance contact between cable shield and gland plate
Cable retention Combined EMC contacting and cable fastening
Installation In conjunction with standard VX gland plates
Application per set One enclosure half
Supply includes 1 gland plate with T-head punching, 1 sliding gland plate and 2 EMC seals
Standard-compliant IP protection category Not supported
Pack quantity 1 pc
Net weight 1.5 kg
Gross weight 1.78 kg
EAN 4028177929869
Customs tariff number 94039910
ETIM 9 EC002620
ECLASS 8.0 27189261

Frequently Asked Questions

What is the Rittal VX8618.822 used for?

The Rittal VX8618.822 is an EMC gland plate used to provide combined cable shield contacting and cable fastening for shielded cables entering compatible Rittal VX enclosures.

What cable diameter can the Rittal VX8618.822 accommodate?

The VX8618.822 is designed for shielded cables with a maximum diameter of 20 mm.

Which enclosure sizes are compatible with the VX8618.822?

The EMC gland plate is designed for 1000 mm wide VX enclosures with depths of 400 mm, 500 mm, 600 mm or 800 mm, in conjunction with the standard gland plates.

What is supplied with the Rittal VX8618.822?

The set includes 1 gland plate with T-head punching, 1 sliding gland plate and 2 EMC seals. One set is intended for one enclosure half.

Does the Rittal VX8618.822 maintain a standard IP protection rating?

No. Rittal specifies that a standard-compliant IP protection category is not supported when using this EMC gland plate configuration.

Trusted Rittal EMC Enclosure Engineering

Rittal VX EMC accessories provide panel builders and system integrators with practical solutions for shielded cable entry, combining low-resistance shield contacting with secure cable retention for professional industrial electrical and automation installations.