NVENT HOFFMAN PCFB1YZ Cont. flow, ext., Y and Z

NVENT HOFFMAN PCFB1YZ Cont. flow, ext., Y and Z

nVent HOFFMAN PCFB1YZ is an exterior-mounted 316L stainless steel continuous flow Type Y and Type Z purge and pressurisation system for protecting electrical equipment in hazardous-location enclosures.

SKU: PCFB1YZMPN: PCFB1YZ
Price
List Price £3,577.00 ex VAT
Your Price (ex VAT) Save 25%
£2,682.75 25% OFF
You save £894.25 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,682.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,682.75

Why Choose the nVent HOFFMAN PCFB1YZ Continuous Flow Purge and Pressurisation System?

The nVent HOFFMAN PCFB1YZ is an exterior-mounted continuous flow purge and pressurisation system designed to help protect electrical and electronic equipment installed in hazardous locations. Using a controlled supply of clean, dry air or inert gas, the system first purges potentially hazardous gases or dust from an enclosure and then maintains positive internal pressure to help prevent hazardous external atmospheres from entering.

Designed for Type Y and Type Z pressurisation applications, the PCFB1YZ combines a control unit, calibrated outlet orifice and relief valve to maintain continuous protective flow through the enclosure. Local visual indication provides system status, while a dry contact output enables connection to a remote alarm system when required.

The PCFB1YZ features exterior mounting and uses 316L stainless steel with a brushed finish for excellent corrosion resistance. It operates with a dry, clean air or inert gas supply between 60–115 psi (4–8 bar) and is typically recommended for enclosures with an internal volume of up to 17 ft³.

Key Advantages

  • Continuous flow purge and pressurisation for hazardous-location enclosure protection.
  • Supports Type Y and Type Z pressurisation applications.
  • Exterior-mounted design simplifies installation and access.
  • Exterior components manufactured from 316 stainless steel or corrosion-resistant composite materials.
  • Local visual indication provides clear system status.
  • Dry contact output supports remote alarm signalling.
  • Uses clean, dry air or inert gas to maintain positive enclosure pressure.

Key Features

  • nVent HOFFMAN purge and pressurisation system.
  • Continuous Flow operating method.
  • Exterior mounting.
  • Type Y and Type Z certification configuration.
  • 316L stainless steel construction with brushed finish.
  • 3.18 mm material thickness.
  • Protective gas supply pressure of 60–115 psi (4–8 bar).
  • Operating temperature range of -20 to +55 °C.
  • Continuous Flow system comprises a control unit, calibrated outlet orifice and relief valve.
  • Local visual system status indication and dry contact remote alarm output.
  • Typically recommended for enclosures up to 17 ft³ in volume.

Reliable Purge and Pressurisation for Hazardous Locations

Purge and pressurisation provides a practical method of protecting electrical equipment installed within hazardous environments. Before normal operation, the enclosure is purged with clean air or inert gas to remove potentially flammable gases or hazardous atmospheres. Positive internal pressure is then maintained so that the surrounding atmosphere is inhibited from entering the enclosure.

The PCFB1YZ uses the continuous flow method, maintaining positive pressure by continuously passing protective gas through the enclosure and controlling the exiting airflow through a calibrated outlet. Type Y pressurisation can permit suitably classified equipment to be used in a higher-risk location, while Type Z pressurisation can permit general-purpose equipment to be used in appropriate Division 2 or Zone 2 applications when the complete installation satisfies the applicable certification and safety requirements.

Typical Applications

  • Hazardous-location electrical and electronic enclosures.
  • Oil, gas and petrochemical processing installations.
  • Chemical and process manufacturing facilities.
  • Industrial control and automation systems.
  • Instrumentation and monitoring enclosures.
  • Electrical equipment installed in applicable Division 1, Division 2, Zone 1 and Zone 2 environments.

Technical Specifications

Tick the specs you need, then view products that match.

Material Stainless Steel 316
Country of Manufacture United States
Manufacturer nVent HOFFMAN
Series / bulletin HLP
Model PCFB1YZ
Product type Purge and pressurisation system
Operation type Continuous Flow
Mounting type Exterior
Certification type Type Y and Type Z
Finish Brushed
Material thickness 3.18 mm
Protective gas supply Dry, clean air or inert gas
Supply pressure 60–115 psi (4–8 bar)
Operating temperature -20 to +55 °C
Recommended enclosure volume Up to 17 ft³
System components Control unit, calibrated outlet orifice and relief valve
Status indication Local visual indicator
Remote signalling Dry contact alarm output
Recommended enclosure protection Type 4, 4X or 12; IP54 recommended minimum
IECEx certification IECEx SIR.0019X
ATEX certificate Sira 14ATEX1045X
UL file E466718
UPC 783510271466
Weight approx. 2.59 kg

Frequently Asked Questions

What is the nVent HOFFMAN PCFB1YZ used for?

The PCFB1YZ is a continuous flow purge and pressurisation system used to help protect electrical and electronic equipment installed within enclosures in hazardous locations by maintaining a positive internal pressure.

Is the PCFB1YZ a Type Y or Type Z system?

The PCFB1YZ is designed for Type Y and Type Z pressurisation applications, subject to the requirements and certification of the complete installation.

What air pressure does the PCFB1YZ require?

The system uses a dry, clean air or inert gas supply between 60–115 psi (4–8 bar).

Is the nVent HOFFMAN PCFB1YZ internally or externally mounted?

The PCFB1YZ is an exterior-mounted model designed for installation on the outside of a compatible enclosure.

What enclosure size is the PCFB1YZ recommended for?

The continuous flow Type Y and Z system is typically recommended for enclosures with an internal volume of up to 17 ft³. Larger enclosures may require longer purging times.

Trusted Hazardous-Location Enclosure Protection

nVent HOFFMAN purge and pressurisation systems provide engineered protection for electrical and electronic equipment in hazardous locations, using controlled protective gas flow, system status monitoring and certified Type Y and Type Z configurations for demanding industrial applications.