DK7979.342 Rittal PDU SWITCHED 16A/3P CEE 42XC13

DK7979.342 Rittal PDU SWITCHED 16A/3P CEE 42XC13

Rittal DK 7979.342 is an 11 kW, 400 V AC, 16 A three-phase switched PDU with a CEE input, 42 individually switchable C13 outlets, per-phase energy measurement and network connectivity for professional IT rack power management.

SKU: DK7979.342Alt SKU: 7979342MPN: DK7979.342
Price
List Price £2,130.06 ex VAT
Your Price (ex VAT) Save 15%
£1,810.55 15% OFF
You save £319.51 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,810.55
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,810.55

Why Choose the Rittal DK 7979.342 PDU Switched?

The Rittal DK 7979.342 is an intelligent three-phase switched Power Distribution Unit (PDU) designed for high-end power distribution, monitoring and remote outlet control within IT racks, server enclosures and data centre infrastructure. As part of the Rittal DK PDU switched series, it combines 42 IEC 60320 C13 outlets with per-phase energy measurement, individually switchable outputs, network connectivity and an integrated display.

Designed for professional IT environments, the DK 7979.342 allows every output slot to be switched individually while monitoring electrical consumption at the infeed and per phase. Programmable switching behaviour, adjustable warning and alarm thresholds and configurable start-up states provide administrators with precise control over connected equipment. Sequential outlet activation following voltage recovery also helps reduce simultaneous inrush-current peaks.

Operating from a 400 V AC, 16 A three-phase supply, the PDU provides a rated power capacity of 11 kW. Its 42 C13 outlets are arranged as 14 outlets per phase, while the slim 44 × 1695 × 70 mm anodised aluminium housing supports space-efficient Zero-U installation in compatible Rittal VX IT and TS IT racks.

Key Advantages

  • Intelligent three-phase switched PDU for high-density IT rack power distribution.
  • 42 individually switchable IEC 60320 C13 outlets for precise equipment power control.
  • 14 C13 outlets per phase support organised three-phase load distribution.
  • 400 V AC, 16 A three-phase input with 11 kW rated power.
  • ±1% active energy measurement accuracy supports dependable power and capacity monitoring.
  • Programmable outlet switching enables time-based and logic-based control.
  • Adjustable warning and alarm thresholds for voltage, current and power.
  • Integrated network connectivity enables remote monitoring and administration.
  • Self-powered design requires no separate external power supply.
  • Supports tool-free Zero-U vertical mounting in compatible Rittal VX IT and TS IT racks.

Key Features

  • Rittal DK PDU switched series.
  • 42 × IEC 60320 C13 output sockets.
  • 14 C13 outlets per phase.
  • Each output slot is individually switchable.
  • 400 V AC rated operating voltage.
  • 16 A maximum rated current.
  • 11 kW rated power.
  • Three-phase EN 60309 / CEE input, 3L+N+PE, 6h.
  • Energy measurement at the infeed and per phase.
  • ±1% active energy measurement accuracy to EN 62053-21.
  • Programmable switch-on behaviour following voltage recovery: on, off or previous status.
  • Programmable switching based on time or configurable logic.
  • Integrated 128 × 128 pixel RGB TFT display.
  • 2 × RJ45 10/100/1000 Mbit/s Ethernet interfaces.
  • Supports SNMP, Modbus/TCP, OPC-UA and other common network protocols.
  • CAN bus interface supports connection of up to 16 compatible sensors.
  • Integrated real-time clock with replaceable battery buffering.
  • Integrated electromagnetic buzzer provides acoustic alarm signalling.
  • Colour-coded phases: L1 pink, L2 black and L3 white.
  • 3 m connection cable for installation.

Intelligent Three-Phase Power Control for IT Racks

Switched PDUs such as the Rittal DK 7979.342 provide significantly greater control than conventional rack power strips. Each of the 42 C13 outputs can be switched individually, enabling administrators to remotely power-cycle connected servers and network devices, create controlled switching sequences and manage equipment power states without physical access to the rack.

Per-phase energy measurement provides visibility into three-phase rack loading, while network connectivity enables integration with data centre and infrastructure management systems. Programmable switching, configurable thresholds, alarm functions and support for up to 16 CAN bus sensors make the DK 7979.342 a comprehensive power management solution for high-density and mission-critical IT installations.

Typical Applications

  • High-density data centre server racks.
  • Remote switching and power cycling of servers.
  • Network and telecommunications equipment.
  • Three-phase rack-level power distribution.
  • Per-phase energy and load monitoring.
  • Remote IT infrastructure management.
  • Rittal VX IT and TS IT rack installations.
  • Zero-U vertical PDU installations.

Technical Specifications

Tick the specs you need, then view products that match.

Material Aluminium
Accessory Type Power Distribution
Manufacturer Rittal
Series DK PDU switched
Model DK 7979.342
Product type Switched Power Distribution Unit (PDU)
Number of outlets 42
Outlet type IEC 60320 C13
Outlets per phase 14
Outlet switching Individually switchable
Rated operating voltage 400 V AC
Rated current 16 A maximum
Rated power 11 kW
Number of infeeds 1
Input phases 3-phase
Input connector EN 60309 / CEE, 3L+N+PE, 6h
Frequency 50–60 Hz
Measurement accuracy ±1% (kWh) to EN 62053-21
Measurement level Infeed / per phase
Connection cable length 3 m
Connection cable type H05-VV
Number of conductors 5
Cable cross-section 2.5 mm²
Display TFT RGB, 128 × 128 pixels
Network interfaces 2 × RJ45 Ethernet, 10/100/1000 Mbit/s
Sensor interface CAN bus RJ45 for up to 16 sensors
USB interface USB 2.0 Type A
Serial interface RS232
Protocols IPv4/IPv6, HTTP, HTTPS, SSL, SSH, NTP, Telnet, DHCP, DNS, Syslog, SNMP v1/v2c/v3, Modbus/TCP, OPC-UA, FTP/SFTP
Digital input 1
Alarm relay 48 V DC / 2 A
Dimensions (W × L × D) 44 × 1695 × 70 mm
Housing material Aluminium
Finish Anodised, RAL 9005 black
Protection rating IP20
Protection class Class I
Pollution degree 2
Overvoltage category II
Operating temperature 5–50 °C
Storage temperature -20–70 °C
Ambient humidity 10–95% RH, non-condensing
MTBF at 40 °C 100,000 hours
Installation Zero-U vertical mounting in compatible VX IT / TS IT racks
Pack quantity 1 pc(s)
EAN 4028177948037
Customs tariff number 85366990

Frequently Asked Questions

What is the Rittal DK 7979.342 used for?

The Rittal DK 7979.342 is a three-phase switched PDU designed to distribute and monitor electrical power while providing individual remote switching control for equipment installed in server racks and professional data centre infrastructure.

How many outlets does the Rittal DK 7979.342 have?

The PDU provides 42 IEC 60320 C13 outlets, with 14 outlets per phase for high-density three-phase rack power distribution.

What electrical supply does the DK 7979.342 require?

The DK 7979.342 operates from a 400 V AC, three-phase, 16 A supply using an EN 60309 / CEE 3L+N+PE input connection and provides a rated power capacity of 11 kW.

Can each outlet on the Rittal DK 7979.342 be switched separately?

Yes. All 42 C13 output slots are individually switchable, allowing connected equipment to be remotely controlled and power-cycled as required.

Can the Rittal DK 7979.342 be monitored remotely?

Yes. The PDU includes Gigabit Ethernet network connectivity and supports protocols including SNMP, Modbus/TCP and OPC-UA, allowing integration with compatible data centre and infrastructure management systems.

Intelligent Power Control for High-Density IT Infrastructure

Rittal PDU switched power distribution units combine high-density three-phase power distribution with individual outlet switching, accurate energy measurement and network-based management for professional data centres, server rooms and critical IT infrastructure.