ABB PDLB2050 (1STQ009419A0000) is a System pro E Power IP40 blind door accessory specified for a 2000 mm nominal height and 500 mm nominal width configuration within compatible low-voltage electrical distribution switchboard enclosures.
£374.59
The ABB PDLB2050 (1STQ009419A0000) is a dedicated IP40 blind door for compatible ABB System pro E Power low-voltage electrical distribution switchboards. The manufacturer specifies a door configuration with a nominal height of 2000 mm, a nominal width of 500 mm and an IP40 ingress protection designation.
The authoritative ABB manufacturer designation, BLIND DOOR IP40 H=2000 W=500MM, identifies the product's essential characteristics: a blind enclosure door, IP40 protection designation, 2000 mm nominal height and 500 mm nominal width. These details are important when selecting the correct external door for a compatible ABB System pro E Power switchboard.
A blind door is an enclosure door without the predefined instrument or operating-device apertures associated with certain other door configurations. This makes the PDLB2050 relevant to switchboard arrangements requiring a plain external door surface rather than a door prepared for specific control or indication equipment.
As part of the ABB System pro E Power product group, the PDLB2050 is intended for integration with compatible modular switchboard enclosure structures. It contributes to the physical enclosure boundary and provides a designated door arrangement for accessing internal switchboard areas, subject to the applicable ABB assembly configuration.
The IP40 designation identifies protection against solid foreign objects of 1.0 mm diameter and greater, together with the corresponding protection against access to hazardous parts defined by IEC/EN 60529. The second numeral, zero, indicates that no rated protection against water ingress is specified.
For electrical panel builders, switchboard manufacturers and maintenance engineers, the ABB PDLB2050 IP40 blind door provides a manufacturer-identified enclosure accessory for the specified 2000 mm by 500 mm nominal configuration. Its ABB order code, 1STQ009419A0000, supports accurate procurement, bill-of-materials preparation, technical documentation and compatible replacement identification.
The ABB PDLB2050 is identified by the manufacturer as a blind door. Within an electrical switchboard, this generally refers to an external door without factory-defined openings for instruments, push-buttons, selector switches or indicator lamps.
This configuration is relevant where a switchboard requires an uninterrupted external door surface. It can also be suitable where the electrical equipment is positioned behind the door and the project does not call for front-mounted operating devices in the door itself.
The blind designation describes the door configuration rather than the complete contents of the product package. It does not establish whether the door is supplied with hinges, locks, handles, earthing accessories or fixing hardware.
These details should be confirmed against ABB's applicable product and assembly documentation before ordering. The exact door construction, material, finish and mounting arrangement are also subject to the manufacturer's technical specifications.
The PDLB2050 should be selected as a manufacturer-specific System pro E Power enclosure accessory, not as a universal door for unrelated electrical cabinets. Correct mechanical compatibility is important for door alignment, operation and the intended protection characteristics of the completed switchboard.
A defining characteristic of the ABB PDLB2050 is its IP40 designation. The IP classification system is established under IEC/EN 60529 and describes the protection provided by an enclosure against access to hazardous parts, solid foreign objects and water.
The first numeral in IP40 is 4. This indicates protection against solid foreign objects with a diameter of 1.0 mm and greater, together with the associated protection against access to hazardous parts specified by the standard.
The second numeral is 0. This indicates that the IP code does not specify a rated level of protection against water ingress.
Consequently, an IP40-designated door should not be described as waterproof, splash-proof or suitable for water jet exposure. Where an installation requires protection against water, the complete switchboard must be designed and verified for an appropriate IP classification.
The IP40 designation of the PDLB2050 is an important selection characteristic, but the final ingress protection rating of the switchboard depends on the complete enclosure. Doors, adjacent panels, enclosure joints, cable entries and other openings must be coordinated according to the manufacturer's assembly instructions.
An individual door does not independently establish the IP rating of an entire switchboard. Correct selection, installation and maintenance of the complete enclosure arrangement are necessary to achieve the intended protection classification.
The ABB PDLB2050 is specified for a 2000 mm nominal height and a 500 mm nominal width. Both dimensions are essential when selecting the correct blind door for the intended System pro E Power enclosure arrangement.
The 2000 mm nominal height identifies the vertical door configuration stated by ABB. This is particularly important when coordinating the door with the corresponding enclosure frame and surrounding structural components.
The 500 mm nominal width identifies the designated enclosure width arrangement. It distinguishes the PDLB2050 from blind doors intended for other nominal widths.
These measurements should not automatically be interpreted as the exact external dimensions of the manufactured door. Actual dimensions may differ from the nominal configuration measurements to accommodate the frame interface, hinge arrangement and installation clearances.
The supplied manufacturer designation does not specify the door thickness, precise hinge positions, opening angle or dimensional tolerances. These characteristics should be checked against the applicable ABB technical drawing.
Matching nominal height and width are necessary selection considerations, but they do not independently establish compatibility with another enclosure system or an alternative door mounting arrangement.
The ABB System pro E Power platform supports modular low-voltage switchboard construction using coordinated enclosure structures, external doors, panels, busbar systems, equipment mounting accessories and internal segregation components.
The PDLB2050 IP40 blind door forms part of this enclosure accessory range. Its function is to provide the specified external door arrangement within a compatible switchboard rather than to perform an electrical switching or protective function.
The door must be selected for the intended enclosure structure and opening. Compatibility should be confirmed against ABB's relevant assembly documentation, particularly where the switchboard incorporates specific frame dimensions, adjacent panels or dedicated mounting accessories.
The completed enclosure's protection classification depends on the arrangement of all relevant components. The PDLB2050 must therefore be considered together with the enclosure frame, neighbouring panels, door mounting system and any additional accessories required by the manufacturer.
Although the PDLB2050 belongs to the System pro E Power range, compatibility should not be assumed with every enclosure configuration in that range. The precise structural arrangement must be verified.
Recording the ABB order code 1STQ009419A0000 in the project bill of materials supports accurate identification during procurement, assembly and future maintenance.
The ABB PDLB2050 and ABB PDLB2056 are both System pro E Power blind door accessories with a 2000 mm nominal height and 500 mm nominal width. However, their manufacturer designations identify different ingress protection configurations.
The PDLB2050 (1STQ009419A0000) is designated BLIND DOOR IP40 H=2000 W=500MM. It is identified for a compatible IP40 enclosure arrangement, where protection against solid foreign objects is specified but no rated water ingress protection is indicated by the IP code.
The PDLB2056 (1STQ009418A0000) is designated BLIND DOOR IP65 H=2000 W=500MM. Its designation identifies a different ingress protection configuration associated with dust-tight and water jet protection requirements.
Although the two products share the same nominal height and width, they should not be assumed to be mechanically interchangeable. Differences in door construction, sealing requirements, mounting components or other features must be checked against ABB technical documentation.
The PDLB2050 should not be substituted for an IP65-designated door solely because the nominal dimensions match. Equally, fitting an IP65-designated door does not automatically upgrade an existing IP40 switchboard to IP65.
The correct selection depends on the required protection classification, the intended enclosure design and the manufacturer-approved assembly arrangement.
External doors provide access to designated internal areas of an electrical switchboard. The suitability of the door arrangement depends on the enclosure design, installed equipment and intended access requirements.
The ABB PDLB2050 is a blind door intended for the specified System pro E Power configuration. The actual opening direction, hinge arrangement and locking method must be established from ABB's relevant technical documentation.
During switchboard design, panel builders should consider the clearance required to open the door, the location of adjacent equipment and any restrictions imposed by the installation environment.
Correct alignment and secure closure are important to the mechanical operation of the door and the intended enclosure protection. Any manufacturer-specified fixing requirements should be followed during installation.
Maintenance inspections should consider the condition of the door surface, hinges, fixings and any associated locking components. Damage, distortion or misalignment may affect the suitability of the completed enclosure.
Where a replacement is required, the exact ABB model and order code should be checked against the original switchboard documentation to avoid selecting a door with unsuitable dimensions or an incorrect IP designation.
The IP40 designation makes the ABB PDLB2050 relevant to switchboard projects requiring the specified protection against solid foreign objects in the completed enclosure.
However, IP40 does not establish rated protection against water ingress. The PDLB2050 should therefore not be assumed suitable for locations exposed to rain, splashing, washdown or other sources of water without additional assessment of the complete enclosure design.
The suitability of a switchboard for its installation environment also depends on ambient temperature, humidity, condensation, corrosion exposure, ventilation and mechanical impact.
The supplied manufacturer designation does not identify the door material, coating, corrosion resistance or impact protection classification. These properties should be verified against ABB's relevant product documentation where they are important to the project.
For outdoor or demanding industrial environments, the required enclosure protection and environmental characteristics should be assessed before selecting the appropriate System pro E Power door configuration.
The IEC/EN 61439 series establishes requirements for low-voltage switchgear and controlgear assemblies. These requirements apply to the completed switchboard, including its enclosure, electrical equipment, busbar system, connections and mechanical construction.
The ABB PDLB2050 is an external enclosure door accessory. Although its manufacturer designation specifies IP40, the final ingress protection classification must be established for the complete enclosure arrangement.
The door does not independently determine the switchboard's rated current, rated voltage, short-circuit withstand capability or temperature-rise performance. These characteristics depend on the complete electrical assembly and its verified design.
Internal separation classifications such as Form 2, Form 3 and Form 4 depend on the arrangement of busbars, functional units, terminals and internal segregation barriers. A blind external door does not independently establish a particular segregation form.
The switchboard manufacturer remains responsible for verifying the completed assembly against the applicable IEC/EN 61439 requirements and ABB System pro E Power assembly instructions.
Before ordering the ABB PDLB2050, confirm that the intended electrical switchboard belongs to the System pro E Power range and requires the specified IP40 blind door configuration.
Check the nominal dimensions carefully. The PDLB2050 is designated for H=2000 and W=500MM, making the 2000 mm nominal height and 500 mm nominal width essential selection criteria.
Verify the enclosure opening, mounting arrangement and required ingress protection classification. The complete enclosure must use compatible components and the manufacturer-specified assembly arrangement to achieve the intended protection rating.
Use the ABB manufacturer order code 1STQ009419A0000 for purchasing, technical enquiries and project documentation. This helps distinguish the PDLB2050 from the IP65-designated PDLB2056 and other blind door variants.
Before installation, consult ABB's applicable technical documentation to confirm the exact physical dimensions, hinge arrangement, locking components, fixings and any additional parts required. The supplied designation does not independently establish which accessories are included.
Installation should be undertaken by appropriately qualified personnel following ABB's assembly instructions. The completed switchboard should be verified for correct door operation, mechanical suitability, enclosure integrity and the relevant electrical requirements before being placed into service.
| Product group | System pro E Power |
|---|---|
| Manufacturer order code | 1STQ009419A0000 |
| Manufacturer designation | BLIND DOOR IP40 H=2000 W=500MM |
| Product type | Blind switchboard enclosure door |
| Product category | Electrical switchboard enclosure accessories |
| Door configuration | Blind |
| Ingress protection designation | IP40 |
| IP first characteristic numeral | 4 — protection against solid foreign objects of 1.0 mm diameter and greater |
| IP second characteristic numeral | 0 — no rated protection against water ingress |
| Nominal door height | 2000 mm |
| Nominal door width | 500 mm |
| Compatible switchboard system | ABB System pro E Power |
| Application | Low-voltage electrical distribution switchboard enclosures |
| Primary function | Blind external door coverage and access within a compatible enclosure arrangement |
| Final assembled enclosure IP rating | Dependent on the complete enclosure configuration and correct installation |
| Ingress protection classification standard | IEC/EN 60529 |
| Applicable low-voltage assembly standard | IEC/EN 61439, as relevant to the completed switchboard |
The ABB PDLB2050 is an IP40 blind door accessory for compatible ABB System pro E Power low-voltage electrical switchboards. It is specified for a 2000 mm nominal height and 500 mm nominal width enclosure configuration.
The official ABB manufacturer order code for the PDLB2050 is 1STQ009419A0000. This reference should be used when ordering or identifying the blind door.
The designation identifies a blind switchboard door with an IP40 ingress protection designation, intended for a 2000 mm nominal height and 500 mm nominal width configuration.
A blind door is an enclosure door without the predefined instrument or operating-device apertures associated with certain other door configurations. The exact construction and supplied fittings of the PDLB2050 should be confirmed against ABB technical documentation.
Under IEC/EN 60529, IP40 identifies protection against solid foreign objects of 1.0 mm diameter and greater, together with the associated protection against access to hazardous parts. The second numeral is zero, meaning no rated protection against water ingress is specified.
The PDLB2050 is specified for a 2000 mm nominal height and 500 mm nominal width. Exact physical door dimensions, thickness and mounting details should be confirmed against ABB technical drawings.
Both doors have a 2000 mm nominal height and 500 mm nominal width. The PDLB2050 (1STQ009419A0000) is designated IP40, while the PDLB2056 (1STQ009418A0000) is designated IP65. They should not be assumed interchangeable without verifying the required enclosure configuration.
The IP40 designation does not specify a rated level of protection against water ingress. The PDLB2050 should not be selected as a water-resistant enclosure solution without separate verification of the complete installation.
The supplied manufacturer designation does not establish whether hinges, locks, handles or fixing accessories are included. Confirm the exact package contents and any required complementary components using ABB product documentation.
Compatibility should not be assumed for every System pro E Power configuration. The PDLB2050 is specifically designated as an IP40 blind door for a 2000 mm nominal height and 500 mm nominal width. The intended enclosure structure and mounting arrangement must be verified against ABB technical documentation.
Any modification to the blind door must be assessed against ABB's installation requirements and the complete enclosure design. Additional holes or equipment apertures may affect the intended IP40 protection classification unless the modified arrangement is appropriately designed and verified.
No. The PDLB2050 is an external enclosure door accessory. Electrical ratings, short-circuit performance and internal segregation classifications depend on the design and verification of the complete switchboard assembly.
ABB System pro E Power accessories support professional modular low-voltage switchboard construction for industrial and commercial electrical distribution. The ABB PDLB2050 IP40 blind door provides a manufacturer-designated enclosure component for electrical engineers, switchboard manufacturers and panel builders requiring a 2000 mm nominal height and 500 mm nominal width blind door arrangement within compatible System pro E Power assemblies.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.