ABB PDLB2056 (1STQ009418A0000) is a System pro E Power IP65 blind door accessory specified for a 2000 mm nominal height and 500 mm nominal width configuration within compatible low-voltage electrical distribution switchboard enclosures.
£481.57
The ABB PDLB2056 (1STQ009418A0000) is a dedicated IP65 blind door accessory for compatible ABB System pro E Power low-voltage electrical distribution switchboards. The manufacturer specifies a blind door configuration with a nominal height of 2000 mm, a nominal width of 500 mm and an IP65 ingress protection designation.
The authoritative ABB manufacturer designation, BLIND DOOR IP65 H=2000 W=500MM, identifies the product's essential characteristics: a blind door, IP65 protection designation, 2000 mm nominal height and 500 mm nominal width. These details are important when selecting the correct enclosure door for a compatible ABB System pro E Power switchboard configuration.
A blind door is an enclosure door without the equipment cut-outs associated with a preconfigured instrument or operating-device door. It is relevant to switchboard designs requiring an uninterrupted external door surface in the specified arrangement. The exact construction, opening direction, locking arrangement and supplied hardware must be confirmed against ABB's applicable technical documentation.
As part of the ABB System pro E Power product group, the PDLB2056 is intended to integrate with compatible modular switchboard enclosure structures. When correctly installed with the specified associated components, the door contributes to the external enclosure boundary and helps provide access to internal switchboard areas while maintaining the intended enclosure configuration.
The IP65 designation is particularly important where the switchboard enclosure must provide a high degree of protection against dust and water jets. Under IEC/EN 60529, IP65 identifies a dust-tight enclosure classification and protection against water jets under standardised test conditions. The final IP rating of the assembled switchboard nevertheless depends on the complete enclosure, its doors, joints, cable entries and sealing arrangements.
For electrical panel builders, switchboard manufacturers and maintenance engineers, the ABB PDLB2056 IP65 blind door provides a manufacturer-identified solution for the specified 2000 mm by 500 mm nominal configuration. Its ABB order code, 1STQ009418A0000, supports accurate procurement, bill-of-materials preparation, project documentation and compatible replacement identification.
The ABB PDLB2056 is identified by the manufacturer as a blind door. In electrical switchboard construction, this terminology generally describes a door without preformed openings for instruments, push-buttons, indicator lamps or other front-mounted operating devices.
This configuration is relevant where the switchboard design calls for a plain external door surface rather than a door prepared for a specific device arrangement. It may also be appropriate where access to internal equipment is required through an enclosure door, while operating devices are located elsewhere in the switchboard design.
The blind designation does not independently establish whether the door includes a lock, handle, hinges, earthing accessories or sealing components. These details must be confirmed from ABB's relevant product documentation.
Although a blind door may appear mechanically straightforward, its installation must be coordinated with the intended enclosure frame and surrounding structural components. Correct alignment, hinge positioning and closure are important to the mechanical operation of the completed assembly.
For an IP65-designated arrangement, the relationship between the door and its surrounding enclosure is particularly important. The complete door interface must use the manufacturer-specified construction and sealing arrangement to achieve the intended ingress protection performance.
The PDLB2056 should therefore be treated as a manufacturer-specific enclosure accessory, rather than a universal replacement door for unrelated electrical cabinets.
One of the principal selection characteristics of the ABB PDLB2056 is its IP65 designation. Ingress protection classifications are defined by IEC/EN 60529 and describe the degree of protection provided by an enclosure against access to hazardous parts, solid foreign objects and water.
The first numeral in IP65 is 6. This represents a dust-tight classification under the specified test conditions. For an electrical switchboard, protection against dust ingress may be important where airborne particles could otherwise enter the enclosure.
The second numeral is 5. This represents protection against water jets directed at the enclosure under the applicable standardised test conditions.
However, IP65 should not be interpreted as unrestricted waterproofing. It does not independently establish suitability for immersion, prolonged flooding, high-pressure cleaning or every possible form of water exposure.
The PDLB2056 blind door is designated IP65 by ABB, but a door alone cannot determine the protection rating of an entire switchboard. The final classification depends on the enclosure structure, adjoining panels, door closure, seals, cable entries and other relevant interfaces.
Any damage to sealing surfaces, incorrectly fitted components or unapproved modifications may compromise the intended ingress protection. For this reason, the door should be installed and maintained in accordance with ABB's applicable enclosure assembly instructions.
The ABB PDLB2056 is specified for a 2000 mm nominal height and a 500 mm nominal width. These measurements are essential when identifying the intended door arrangement within the System pro E Power range.
The 2000 mm nominal height identifies the vertical enclosure configuration stated in the manufacturer designation. This is important when selecting a door for the corresponding switchboard section and coordinating it with the surrounding enclosure structure.
The 500 mm nominal width identifies the associated door width configuration. It distinguishes the PDLB2056 from blind doors intended for other nominal enclosure widths.
These measurements should not automatically be interpreted as the exact external dimensions of the manufactured door. Actual door dimensions may differ from the nominal configuration measurements to accommodate the frame interface, mounting arrangement and required clearances.
The manufacturer designation does not establish the door thickness, exact hinge positions, opening angle or dimensional tolerances. These characteristics should be confirmed against ABB's applicable technical drawings.
When selecting the PDLB2056, both nominal dimensions must be checked. A matching height does not establish suitability for a different width, while matching nominal dimensions alone do not confirm compatibility with another enclosure system.
The ABB System pro E Power platform supports modular construction of low-voltage electrical distribution switchboards using coordinated enclosure structures, doors, external panels, busbar systems, mounting accessories and internal segregation components.
The PDLB2056 IP65 blind door forms part of this enclosure accessory range. Its primary role is to provide the specified external door arrangement within a compatible switchboard, rather than to perform an electrical switching or protection function.
The door must be selected for the intended enclosure structure and opening. Compatibility should be confirmed using ABB's relevant assembly documentation, particularly where the switchboard incorporates specific frame dimensions, neighbouring panels or dedicated door mounting accessories.
Where the switchboard requires an IP65 enclosure configuration, all relevant components must be coordinated. The door, enclosure frame, external panels, joints, seals and cable entry arrangements collectively influence the protection achieved by the completed assembly.
The ABB PDLB2056 should not be assumed compatible with every System pro E Power enclosure solely because it belongs to the same product group. The precise configuration must match the applicable manufacturer-approved arrangement.
Recording the ABB manufacturer order code 1STQ009418A0000 in the project bill of materials helps ensure that the correct door is identified during procurement, assembly and future replacement.
External doors provide access to designated internal areas of an electrical switchboard. The suitability of a particular door arrangement depends on the enclosure design, installed equipment and intended access requirements.
The ABB PDLB2056 is a blind door intended for the specified System pro E Power configuration. The actual access arrangement, opening direction and locking method must be established from the relevant ABB documentation.
During switchboard design, panel builders should consider the space required to open the door, the location of adjacent equipment and any restrictions imposed by the installation environment. Adequate working access must be provided in accordance with applicable electrical safety requirements.
For IP65-designated enclosures, door closure and sealing are particularly important. The relevant seals, hinges and locking components must be correctly selected and installed to maintain the intended enclosure performance.
Routine inspection should consider the condition of the door surface, hinge arrangement, fixing points and any associated seals. Damage, misalignment or incomplete closure may affect the mechanical suitability and ingress protection of the finished enclosure.
Where a replacement is required, the exact ABB model and order code should be checked against the original switchboard documentation to avoid selecting a door with an unsuitable width, height or IP designation.
The IP65 designation makes the ABB PDLB2056 relevant to switchboard projects requiring dust-tight and water jet protection characteristics in the completed enclosure.
However, the suitability of a switchboard for a particular installation environment depends on more than its IP classification. Other relevant considerations include ambient temperature, humidity, condensation, corrosion exposure, mechanical impact and ventilation requirements.
The supplied manufacturer designation does not identify the door material, surface finish, corrosion resistance or impact protection classification. These properties should be verified using ABB's relevant product datasheet where they are important to the project.
An IP65 designation does not independently confirm that the PDLB2056 is suitable for permanent outdoor installation, marine environments, corrosive industrial atmospheres or high-pressure washdown applications.
Any outdoor or demanding environmental application should be assessed against the verified characteristics of the complete System pro E Power enclosure and the conditions at the installation site.
The IEC/EN 61439 series establishes requirements for low-voltage switchgear and controlgear assemblies. These requirements apply to the completed switchboard, including its enclosure, electrical equipment, busbar system, connections and mechanical construction.
The ABB PDLB2056 is an external enclosure door accessory. Although its manufacturer designation specifies IP65, the final ingress protection classification must be established for the complete enclosure arrangement.
The door does not independently determine the switchboard's rated current, rated voltage, short-circuit withstand capability or temperature-rise performance. These characteristics depend on the complete electrical assembly and its verified design.
Internal separation classifications such as Form 2, Form 3 and Form 4 depend on the arrangement of busbars, functional units, terminals and internal segregation barriers. A blind external door does not independently establish a particular segregation form.
The switchboard manufacturer remains responsible for verifying the completed assembly against the applicable IEC/EN 61439 requirements and ABB System pro E Power assembly instructions.
Before ordering the ABB PDLB2056, confirm that the intended electrical switchboard belongs to the System pro E Power range and requires the specified IP65 blind door configuration.
Check the nominal dimensions carefully. The PDLB2056 is designated for H=2000 and W=500MM, making the 2000 mm nominal height and 500 mm nominal width essential selection criteria.
Verify the door opening, mounting arrangement and required ingress protection level. The complete enclosure must use compatible components and the appropriate manufacturer-specified sealing arrangement to achieve the intended IP65 classification.
Use the ABB manufacturer order code 1STQ009418A0000 for purchasing, technical enquiries and project documentation. This helps distinguish the PDLB2056 from other blind doors, glazed doors or external enclosure accessories with different nominal dimensions.
Before installation, consult ABB's applicable technical documentation to confirm the exact physical dimensions, hinge arrangement, locking components, seals, fixings and any additional parts required. The supplied designation does not independently establish which of these items are included.
Installation should be undertaken by appropriately qualified personnel following ABB's assembly instructions. The completed switchboard should be verified for correct door operation, mechanical suitability, enclosure integrity and the relevant electrical requirements before being placed into service.
| Product group | System pro E Power |
|---|---|
| Manufacturer order code | 1STQ009418A0000 |
| Manufacturer designation | BLIND DOOR IP65 H=2000 W=500MM |
| Product type | Blind switchboard enclosure door |
| Product category | Electrical switchboard enclosure accessories |
| Door configuration | Blind |
| Ingress protection designation | IP65 |
| IP first characteristic numeral | 6 — dust-tight classification |
| IP second characteristic numeral | 5 — protection against water jets |
| Nominal door height | 2000 mm |
| Nominal door width | 500 mm |
| Compatible switchboard system | ABB System pro E Power |
| Application | Low-voltage electrical distribution switchboard enclosures |
| Primary function | External blind door coverage and access within a compatible enclosure configuration |
| Final assembled enclosure IP rating | Dependent on the complete enclosure configuration and correct installation |
| Ingress protection classification standard | IEC/EN 60529 |
| Applicable low-voltage assembly standard | IEC/EN 61439, as relevant to the completed switchboard |
The ABB PDLB2056 is an IP65 blind door accessory for compatible ABB System pro E Power low-voltage electrical switchboards. It is specified for a 2000 mm nominal height and 500 mm nominal width enclosure configuration.
The official ABB manufacturer order code for the PDLB2056 is 1STQ009418A0000. This reference should be used when ordering or identifying the blind door.
The designation identifies a blind switchboard door with an IP65 ingress protection designation, intended for a 2000 mm nominal height and 500 mm nominal width configuration.
A blind door is an enclosure door without the predefined instrument or operating-device apertures associated with certain other door configurations. The exact construction and supplied fittings of the PDLB2056 should be confirmed against ABB technical documentation.
Under IEC/EN 60529, IP65 denotes a dust-tight enclosure classification and protection against water jets under specified test conditions. The final ingress protection rating depends on the complete switchboard enclosure and correct installation of all associated components.
The PDLB2056 is specified for a 2000 mm nominal height and 500 mm nominal width. Exact physical door dimensions, thickness and mounting details should be confirmed against ABB technical drawings.
No. The PDLB2056 carries an IP65 designation, but the final ingress protection rating depends on the complete enclosure configuration, compatible panels, door seals, joints, cable entries and correct assembly. A single door does not independently establish the rating of an entire switchboard.
IP65 indicates protection against water jets under standardised test conditions, but it does not establish suitability for immersion, high-pressure cleaning or unrestricted water exposure. The protection achieved by the finished switchboard depends on its complete enclosure and sealing arrangement.
The supplied manufacturer designation does not establish whether hinges, locks, handles, door seals or fixing accessories are included. Confirm the exact package contents and any required complementary components using ABB product documentation.
Compatibility should not be assumed for every System pro E Power configuration. The PDLB2056 is specifically designated as an IP65 blind door for a 2000 mm nominal height and 500 mm nominal width. The intended enclosure structure and mounting arrangement must be verified against ABB technical documentation.
Any modification to the blind door must be assessed against ABB's installation requirements and the complete enclosure design. Additional holes or equipment apertures may compromise the intended IP65 performance unless suitable components and a verified sealing arrangement are used.
No. The PDLB2056 is an external enclosure door accessory. Electrical ratings, short-circuit performance and internal segregation classifications depend on the design and verification of the complete switchboard assembly.
ABB System pro E Power accessories support professional modular low-voltage switchboard construction for industrial and commercial electrical distribution. The ABB PDLB2056 IP65 blind door provides a manufacturer-designated enclosure component for electrical engineers, switchboard manufacturers and panel builders requiring a 2000 mm nominal height and 500 mm nominal width blind door arrangement within compatible System pro E Power assemblies.
We use cookies