Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB PRBE1243 (1STQ009285A0000) is a System pro E Power installation kit for compatible ABB SACE Emax 2 E1.2 3-pole and 4-pole withdrawable circuit-breaker configurations, specified for a vertical reduced mounting arrangement with a nominal width of 400 mm.
£216.21
The ABB PRBE1243 (1STQ009285A0000) is a dedicated vertical reduced-width installation kit for compatible ABB SACE Emax 2 E1.2 withdrawable air circuit-breaker arrangements within the ABB System pro E Power low-voltage switchboard system. The manufacturer specifies compatibility with 3-pole and 4-pole E1.2 withdrawable circuit-breaker configurations and a nominal installation width of 400 mm.
The authoritative ABB product designation, E1.2 KIT 3-4P WITHDR. V.REDUCED W=400MM, identifies the accessory's principal characteristics: an E1.2 circuit-breaker installation kit, compatibility with three- and four-pole arrangements, withdrawable execution, vertical reduced configuration and a nominal width of 400 mm.
Designed as part of the ABB System pro E Power modular switchboard accessory range, the PRBE1243 supports the mechanical integration of the specified ABB SACE Emax 2 circuit-breaker configuration into a compatible distribution assembly. It is particularly relevant where the switchboard design calls for a vertical reduced-width arrangement rather than a conventional installation configuration.
For electrical panel builders, switchboard manufacturers and distribution system engineers, the ABB PRBE1243 E1.2 withdrawable breaker kit provides a clearly identified manufacturer-specific accessory. Its ABB order code, 1STQ009285A0000, supports accurate purchasing, technical specification, switchboard bills of materials and maintenance documentation.
The PRBE1243 is an installation kit, not a complete circuit-breaker. The manufacturer designation does not establish that the E1.2 circuit-breaker, withdrawable fixed part, electrical terminals, interlocks or all associated mounting components are supplied. Package contents and required complementary accessories must be confirmed against the applicable ABB documentation.
The ABB PRBE1243 is identified for the ABB SACE Emax 2 E1.2 circuit-breaker frame. The Emax 2 range comprises low-voltage air circuit-breakers used in electrical power distribution systems, with different frame sizes, pole configurations and installation executions available according to the selected device.
The manufacturer designation specifically identifies the E1.2 frame. This is an important compatibility requirement because installation kits for other Emax 2 frame sizes may differ in their mounting arrangement, dimensions and associated components.
The PRBE1243 is also designated for 3-pole and 4-pole configurations. This allows the product to be identified for the corresponding E1.2 pole arrangements, subject to verification of the exact circuit-breaker variant and the applicable ABB mounting instructions.
The kit should not be assumed to accommodate ABB SACE Emax 2 E2.2, E4.2 or E6.2 frames, nor other circuit-breaker families such as ABB SACE Tmax XT. Compatibility with any device outside the specified E1.2 configuration must be established separately by ABB documentation.
The PRBE1243 provides a manufacturer-designated installation accessory, while the electrical protection characteristics of the completed arrangement depend on the particular E1.2 circuit-breaker selected, its trip unit, ratings and associated electrical connections.
The designation WITHDR. identifies the withdrawable execution for which the ABB PRBE1243 is intended. Withdrawable air circuit-breaker arrangements are used in switchboard designs where the circuit-breaker moving part is installed in conjunction with a compatible fixed part and associated connection and operating mechanisms.
Depending on the selected Emax 2 device and installation configuration, a withdrawable arrangement can provide defined operating positions for the circuit-breaker. The actual operating procedure, position indications and interlocking arrangements depend on the specific device and its installed accessories.
The PRBE1243 must therefore be selected with the appropriate ABB SACE Emax 2 E1.2 withdrawable circuit-breaker configuration. It should not be treated as interchangeable with a kit intended for a fixed circuit-breaker installation.
The manufacturer designation does not confirm whether the withdrawable fixed part, moving circuit-breaker, racking mechanism, auxiliary contacts, shutters or interlocks are included in the PRBE1243 package. These items must be checked against ABB's relevant product and assembly documentation.
All withdrawable circuit-breaker installations must follow the manufacturer's requirements for mechanical alignment, electrical connections, operating clearances and safe operation. The completed arrangement should be checked as part of the overall switchboard assembly verification.
A defining feature of the ABB PRBE1243 is its vertical reduced configuration. The manufacturer's designation identifies a specific installation arrangement rather than a universal circuit-breaker mounting solution.
The term vertical describes the designated mounting arrangement within the switchboard system. The term reduced identifies the corresponding reduced configuration specified by ABB. The exact meaning of this arrangement in relation to the enclosure structure and supporting components should be confirmed from the applicable System pro E Power technical drawings.
The 400 mm nominal width is a key selection characteristic. It identifies the width configuration for which the PRBE1243 is designated and should be checked against the intended switchboard compartment or mounting arrangement.
The 400 mm value should not automatically be interpreted as the precise physical width of every component supplied in the kit. Exact dimensions, mounting positions and installation clearances must be established from ABB's technical documentation.
Where the switchboard design also uses a compatible fixed reduced frame or other reduced-width structural components, the required combination should be confirmed against ABB's approved assembly arrangement. Matching nominal widths alone does not establish mechanical compatibility between two accessories.
The ABB System pro E Power platform supports modular low-voltage switchboard construction using coordinated enclosure structures, mounting accessories, busbar arrangements, circuit-breaker installation components and internal segregation systems.
The PRBE1243 E1.2 withdrawable installation kit forms part of this modular approach. Its purpose is to support the specified circuit-breaker installation arrangement within a compatible switchboard, rather than to provide a complete electrical distribution assembly by itself.
A suitable installation requires coordination between the kit, the selected E1.2 withdrawable circuit-breaker, its associated fixed part, the switchboard structure and the electrical connection arrangement. The precise combination of components must be determined from ABB's applicable assembly documentation.
The panel builder should also consider access for installation, inspection and maintenance, together with the position of adjacent functional units, busbars and cable connection areas. These factors influence the mechanical and electrical suitability of the complete switchboard design.
Using the correct ABB manufacturer reference, 1STQ009285A0000, helps distinguish the PRBE1243 from other Emax 2 mounting accessories that may be intended for different frame sizes, pole configurations, circuit-breaker executions or installation widths.
The IEC/EN 61439 series establishes requirements for low-voltage switchgear and controlgear assemblies. Compliance must be assessed for the completed switchboard, including its enclosure, protective devices, busbar system, electrical connections and supporting mechanical structures.
The ABB PRBE1243 is an installation accessory and should not be assigned independent electrical ratings that are not established by its manufacturer designation. The supplied specification does not determine the rated current, rated voltage, breaking capacity or short-circuit withstand capability of the finished switchboard.
The relevant electrical characteristics depend on the selected ABB SACE Emax 2 E1.2 circuit-breaker, its exact execution, trip unit, connection arrangement and the verified switchboard design.
Internal separation classifications such as Form 2, Form 3 and Form 4 depend on the complete arrangement of busbars, functional units, terminals and segregation barriers. The PRBE1243 does not independently establish a particular segregation form or subdivision.
The switchboard manufacturer remains responsible for verifying the completed assembly against the applicable IEC/EN 61439 requirements and ABB System pro E Power assembly instructions, including relevant mechanical and electrical performance considerations.
Before ordering the ABB PRBE1243, confirm that the intended switchboard belongs to the System pro E Power range and requires the specified vertical reduced installation arrangement.
Verify that the selected circuit-breaker is an ABB SACE Emax 2 E1.2 in the appropriate withdrawable execution. The manufacturer designation supports both 3-pole and 4-pole configurations, but the exact breaker variant and associated components must be checked.
Confirm that the installation calls for the specified 400 mm nominal width. The enclosure structure, mounting arrangement and neighbouring components should be checked against the relevant ABB technical drawings.
Use the ABB order code 1STQ009285A0000 when purchasing the installation kit or recording it in the project bill of materials. This helps prevent confusion with fixed-execution kits or accessories intended for other Emax 2 frame sizes.
Before assembly, verify the exact supplied contents, required fixings, circuit-breaker fixed part, electrical connections and any complementary installation accessories. The PRBE1243 designation does not independently confirm that these items are included.
Installation should be undertaken by appropriately qualified personnel following ABB's applicable instructions. The completed circuit-breaker arrangement and switchboard must be checked for mechanical compatibility, safe operation and the relevant electrical requirements before being placed into service.
| Product group | System pro E Power |
|---|---|
| Manufacturer order code | 1STQ009285A0000 |
| Manufacturer designation | E1.2 KIT 3-4P WITHDR. V.REDUCED W=400MM |
| Product type | Withdrawable circuit-breaker installation kit |
| Product category | Electrical switchboard circuit-breaker mounting accessories |
| Intended circuit-breaker range | ABB SACE Emax 2 |
| Specified circuit-breaker frame | E1.2 |
| Supported pole configurations | 3-pole / 4-pole |
| Circuit-breaker execution | Withdrawable |
| Mounting configuration | Vertical reduced |
| Nominal installation width | 400 mm |
| Compatible switchboard system | ABB System pro E Power |
| Application | Low-voltage electrical distribution switchboards |
| Primary function | Supporting installation of the designated E1.2 withdrawable circuit-breaker arrangement |
| Circuit-breaker included | Not established by the supplied manufacturer designation |
| Withdrawable fixed part included | Not established by the supplied manufacturer designation |
| Electrical ratings | Determined by the selected circuit-breaker and complete verified switchboard assembly |
| Applicable assembly standard | IEC/EN 61439, as relevant to the completed switchboard |
The ABB PRBE1243 is an installation kit for compatible ABB SACE Emax 2 E1.2 withdrawable circuit-breakers within ABB System pro E Power switchboards. It is specified for 3-pole or 4-pole configurations in a vertical reduced arrangement with a nominal width of 400 mm.
The official ABB manufacturer order code for the PRBE1243 is 1STQ009285A0000. This reference should be used when ordering or identifying the installation kit.
The designation identifies an ABB SACE Emax 2 E1.2 installation kit for 3-pole or 4-pole withdrawable circuit-breaker configurations, intended for a vertical reduced mounting arrangement with a 400 mm nominal width.
The PRBE1243 is designated for the ABB SACE Emax 2 E1.2 circuit-breaker frame in withdrawable execution. Compatibility with the exact breaker variant should be verified using ABB technical documentation.
Yes. The manufacturer's 3-4P designation identifies compatibility with the specified 3-pole and 4-pole E1.2 withdrawable arrangements, subject to the applicable ABB assembly requirements.
The PRBE1243 is specifically designated for withdrawable execution. It should not be assumed suitable for a fixed E1.2 circuit-breaker installation without explicit confirmation from ABB technical documentation.
Vertical reduced identifies the manufacturer-specified mounting configuration for the installation kit. The precise structural arrangement and associated mounting requirements should be confirmed against ABB System pro E Power assembly drawings.
The PRBE1243 is specified for a 400 mm nominal installation width. This identifies the intended switchboard configuration and should not automatically be treated as the exact physical width of every component in the kit.
The supplied manufacturer designation identifies an E1.2 installation kit but does not confirm that the circuit-breaker itself is included. The exact package contents should be checked against ABB product documentation before ordering.
The designation does not establish whether the withdrawable fixed part, racking accessories, interlocks or other associated components are supplied. Confirm the included items and any required complementary parts using ABB technical documentation.
The PRBE1243 is specifically designated for the Emax 2 E1.2 frame. Compatibility with E2.2 or other circuit-breaker frames should not be assumed. Select the installation kit specified by ABB for the intended breaker and switchboard arrangement.
No. The PRBE1243 is a circuit-breaker installation accessory. Electrical ratings, short-circuit performance and internal segregation classifications depend on the selected equipment and the design and verification of the complete switchboard assembly.
Confirm the ABB System pro E Power enclosure configuration, Emax 2 E1.2 withdrawable circuit-breaker, required 3-pole or 4-pole arrangement, vertical reduced mounting configuration and 400 mm nominal width. Also verify the kit contents, fixed part, mounting components and electrical connection requirements against ABB's applicable assembly instructions.
ABB System pro E Power accessories support professional modular low-voltage switchboard construction for industrial and commercial electrical distribution. The ABB PRBE1243 Emax 2 E1.2 withdrawable installation kit provides a manufacturer-designated solution for electrical engineers, switchboard manufacturers and panel builders requiring a 3-pole or 4-pole E1.2 withdrawable circuit-breaker arrangement in a vertical reduced 400 mm nominal width configuration.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.