ABB PVCX3707 (1STQ009149A0000) is a System pro E Power vertical installation kit for three compatible ABB SACE Tmax XT3 3-pole plug-in circuit-breakers in a 600 mm nominal width low-voltage switchboard configuration.
£160.78
The ABB PVCX3707 (1STQ009149A0000) is a dedicated vertical installation kit for three ABB SACE Tmax XT3 circuit-breakers within compatible ABB System pro E Power low-voltage electrical distribution switchboards. Specifically designated for 3-pole plug-in XT3 circuit-breakers, this accessory is intended for a 600 mm nominal switchboard width and supports a coordinated three-device mounting arrangement.
The authoritative manufacturer designation, 3 XT3 KIT 3P PLUG IN VERT.W=600MM, identifies the essential installation characteristics: three XT3 circuit-breakers, three-pole configuration, plug-in execution, vertical mounting orientation and a nominal switchboard width of 600 mm. These requirements make the PVCX3707 a configuration-specific component for electrical engineers and panel builders designing modular distribution assemblies.
As part of the ABB System pro E Power product group, the PVCX3707 is intended for integration with compatible switchboard enclosure structures and circuit-breaker installation components. Its three-device arrangement is particularly relevant where multiple outgoing circuits require individual protection using compatible ABB SACE Tmax XT3 moulded-case circuit-breakers.
The ABB PVCX3707 XT3 plug-in installation kit provides a clearly identified solution for professional switchboard construction. Its manufacturer order code, 1STQ009149A0000, supports accurate product selection, purchasing, bill-of-materials preparation and compatible replacement identification.
The ABB PVCX3707 installation kit is specifically identified for an arrangement incorporating three ABB SACE Tmax XT3 moulded-case circuit-breakers. The XT3 frame belongs to ABB's SACE Tmax XT family, which is used in low-voltage power distribution applications requiring circuit protection and switching functionality.
The three-device configuration distinguishes the PVCX3707 from installation kits designed for one or two circuit-breakers. In a distribution switchboard, multiple protective devices may be required to supply separate outgoing feeders, individual equipment circuits or distinct sections of an electrical installation. A dedicated three-device kit supports the intended mechanical arrangement for compatible XT3 equipment.
The manufacturer designation explicitly specifies 3-pole XT3 circuit-breakers. Three-pole moulded-case circuit-breakers are commonly used for three-phase circuits, where protection and switching are required across the three phase conductors. The PVCX3707 should therefore be selected for the specified three-pole arrangement rather than assuming compatibility with four-pole alternatives.
Another essential characteristic is the plug-in execution. Plug-in circuit-breakers are designed to interface with compatible plug-in connection equipment, enabling the circuit-breaker to be fitted into its intended mounting arrangement. This differs from fixed and withdrawable circuit-breaker executions, which may require different installation accessories and connection structures.
The PVCX3707 should be selected only after confirming that all three intended XT3 devices have the correct frame, pole configuration and plug-in execution. The compatibility of associated bases, terminals, connectors and auxiliary equipment should also be checked against the relevant ABB technical documentation.
The vertical mounting orientation is a defining feature of the ABB PVCX3707. Within a modular low-voltage switchboard, the position and orientation of circuit-breakers influence the arrangement of mounting structures, electrical connections, cable routing and adjacent equipment.
The manufacturer's designation identifies a 600 mm nominal switchboard width. This is a compatibility dimension associated with the intended enclosure arrangement, not necessarily the overall physical width of the installation kit. Exact component dimensions, fixing positions and mounting clearances should be confirmed using ABB technical drawings.
The three-device vertical configuration is particularly relevant where the switchboard design calls for multiple XT3 circuit-breakers within the specified equipment section. The installation arrangement should be coordinated with the enclosure structure and the space needed for circuit-breaker operation, electrical connections and any required accessories.
Panel builders should also consider the thermal and electrical requirements of the complete assembly. Installing several protective devices within one section can influence conductor routing, ventilation and the arrangement of nearby equipment. These considerations must be addressed using the applicable ABB design and verification information.
The ABB PVCX3707 provides the designated installation configuration, but it does not independently establish the current-carrying capacity, short-circuit performance or temperature-rise characteristics of the completed switchboard.
The ABB System pro E Power platform supports modular construction of low-voltage electrical switchboards. Compatible assemblies may incorporate enclosure frames, busbar systems, moulded-case circuit-breakers, internal segregation barriers, cable connection arrangements and dedicated mounting accessories.
The PVCX3707 is intended to support the mechanical installation of three compatible XT3 plug-in circuit-breakers within this coordinated system. It should be considered alongside the selected enclosure configuration, the circuit-breaker connection equipment and any associated structural or mounting components.
Using a manufacturer-designated kit helps maintain consistency between the switchboard design and the components used during assembly. The exact ABB order code, 1STQ009149A0000, should be included in technical schedules and procurement documentation to distinguish the PVCX3707 from other XT3 installation kits.
The accessory is not itself a protective circuit-breaker. Its purpose is associated with the installation of compatible devices, while the electrical protection characteristics depend on the selected XT3 circuit-breakers, their trip units and the overall electrical design.
Where a switchboard requires additional internal segregation, the appropriate barriers and structural components must be selected separately in accordance with the intended assembly configuration. The PVCX3707 does not independently establish a Form 2, Form 3 or Form 4 internal separation arrangement.
Low-voltage switchboard assemblies are subject to relevant design and verification requirements under the IEC/EN 61439 series. These requirements address the performance of the complete assembly rather than treating an individual mechanical installation accessory as a complete electrical product.
When integrating the ABB PVCX3707, the switchboard manufacturer must consider the selected circuit-breakers, busbar connections, conductors, enclosure arrangement and applicable installation conditions. The completed assembly must satisfy the relevant requirements for its intended electrical ratings and operating environment.
The installation kit does not independently determine the rated operational current, rated insulation voltage, short-circuit withstand capability or ingress protection of the finished switchboard. These characteristics depend on the complete verified design.
Similarly, any internal segregation classification must be established by the complete arrangement of busbars, functional units, terminals and separation barriers. The PVCX3707 should therefore be treated as a dedicated circuit-breaker mounting accessory within the wider switchboard system.
Before ordering the ABB PVCX3707, confirm that the intended electrical switchboard belongs to the System pro E Power range and incorporates the appropriate 600 mm nominal width configuration.
The installation must require three ABB SACE Tmax XT3 circuit-breakers in a vertical arrangement. Each selected circuit-breaker should be a compatible 3-pole plug-in execution, as specified by the manufacturer's designation.
The product should be ordered using ABB manufacturer code 1STQ009149A0000. This is particularly important when distinguishing the PVCX3707 from other installation kits intended for two devices, four-pole circuit-breakers, different XT frames or alternative mounting arrangements.
Before assembly, verify the kit's supplied components, mounting instructions, fixing requirements and compatibility with the intended plug-in bases and electrical connection equipment. The manufacturer's designation does not establish that the three circuit-breakers themselves are included in the kit.
Installation should be undertaken by appropriately qualified personnel in accordance with ABB's applicable assembly instructions. The completed switchboard must be verified as a whole to confirm its mechanical suitability and electrical performance.
| Product group | System pro E Power |
|---|---|
| Manufacturer order code | 1STQ009149A0000 |
| Product designation | 3 XT3 KIT 3P PLUG IN VERT.W=600MM |
| Product type | Circuit-breaker installation kit |
| Product category | Electrical switchboard mounting accessories |
| Compatible circuit-breaker family | ABB SACE Tmax XT |
| Compatible circuit-breaker frame | XT3 |
| Specified circuit-breaker quantity | 3 |
| Supported pole configuration | 3-pole |
| Circuit-breaker execution | Plug-in |
| Installation orientation | Vertical |
| Nominal switchboard width | 600 mm |
| Compatible switchboard system | ABB System pro E Power |
| Primary function | Installation of three compatible XT3 plug-in circuit-breakers |
| Application | Low-voltage electrical distribution switchboards |
| Mounting arrangement | Vertical circuit-breaker installation |
| Physical kit dimensions | Confirm against the applicable ABB technical drawing |
| Material and finish | Confirm against the ABB product datasheet |
| Kit contents | Confirm against ABB assembly documentation |
| Net weight | Confirm against the ABB product datasheet |
| Circuit-breakers included | Not established by the supplied designation; verify package contents before ordering |
| Electrical ratings | Determined by the selected circuit-breakers and complete switchboard assembly |
| Applicable assembly standard | IEC/EN 61439, as relevant to the completed switchboard |
The ABB PVCX3707 is an installation kit designed for a vertical arrangement of three compatible ABB SACE Tmax XT3 3-pole plug-in circuit-breakers within a 600 mm nominal width ABB System pro E Power switchboard configuration.
The official ABB manufacturer order code for the PVCX3707 is 1STQ009149A0000. This reference should be used when ordering or identifying the installation kit.
The manufacturer designation specifies an installation arrangement for three ABB SACE Tmax XT3 circuit-breakers. All three devices must be compatible with the required 3-pole plug-in execution and vertical mounting configuration.
The PVCX3707 is specifically designated for 3-pole XT3 circuit-breakers. Compatibility with 4-pole versions should not be assumed. A different ABB installation kit may be required for a four-pole arrangement.
The designation identifies a kit for three XT3 circuit-breakers, each with a 3-pole plug-in configuration, installed in a vertical arrangement within a switchboard having a 600 mm nominal width.
The PVCX3707 is specified for three 3-pole XT3 plug-in circuit-breakers, while the PVCX3607 is specified for two XT3 plug-in circuit-breakers in 3-pole or 4-pole configurations. Both are designated for vertical installation in a 600 mm nominal width System pro E Power arrangement.
The manufacturer designation describes an installation kit for three XT3 circuit-breakers, but it does not establish that the circuit-breakers themselves are supplied. Confirm the package contents and any required plug-in connection components before ordering.
The PVCX3707 is specifically designated for plug-in XT3 circuit-breaker installations. Compatibility with fixed or withdrawable executions should not be assumed. Select the ABB installation kit specified for the required device execution.
Not necessarily. The 600 mm measurement identifies the nominal switchboard width associated with the intended installation configuration. The exact physical dimensions of the kit should be confirmed using the applicable ABB technical drawing.
The PVCX3707 is specifically identified for the ABB SACE Tmax XT3 frame. Compatibility with XT1, XT2, XT4 or other circuit-breaker frames should not be assumed. Use the manufacturer-designated kit for the selected circuit-breaker.
No. The PVCX3707 is a circuit-breaker installation accessory. The rated current, breaking capacity, protection characteristics and other electrical performance requirements depend on the selected XT3 devices and the verified complete switchboard assembly.
Confirm the ABB System pro E Power enclosure configuration, 600 mm nominal width, requirement for three XT3 circuit-breakers, correct 3-pole plug-in execution and vertical mounting orientation. Verify the kit contents, fixing requirements and associated plug-in connection components against ABB's assembly documentation.
ABB System pro E Power accessories support professional modular low-voltage switchboard construction for industrial and commercial power distribution. The ABB PVCX3707 XT3 plug-in vertical installation kit provides a dedicated solution for electrical engineers, switchboard manufacturers and panel builders integrating three compatible 3-pole ABB SACE Tmax XT3 circuit-breakers into a 600 mm nominal width System pro E Power switchboard arrangement.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.