1STQ009149A0000 ABB PVCX3707 Three XT3 3-Pole Plug-In Circuit-Breaker Vertical Installation Kit W600 System pro E Power

1STQ009149A0000 ABB PVCX3707 Three XT3 3-Pole Plug-In Circuit-Breaker Vertical Installation Kit W600 System pro E Power

ABB PVCX3707 (1STQ009149A0000) is a System pro E Power vertical installation kit for three compatible ABB SACE Tmax XT3 3-pole plug-in circuit-breakers in a 600 mm nominal width low-voltage switchboard configuration.

SKU: 1STQ009149A0000Alt SKU: PVCX3707MPN: 1STQ009149A0000
Price
List Price £160.78 ex VAT
Your Price (ex VAT)
£160.78
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £160.78
Trade pricing is personalised to your account

Manufacturer Lead Time

£160.78

Why Choose the ABB PVCX3707 System pro E Power XT3 Plug-In Vertical Installation Kit?

The ABB PVCX3707 (1STQ009149A0000) is a dedicated vertical installation kit for three ABB SACE Tmax XT3 circuit-breakers within compatible ABB System pro E Power low-voltage electrical distribution switchboards. Specifically designated for 3-pole plug-in XT3 circuit-breakers, this accessory is intended for a 600 mm nominal switchboard width and supports a coordinated three-device mounting arrangement.

The authoritative manufacturer designation, 3 XT3 KIT 3P PLUG IN VERT.W=600MM, identifies the essential installation characteristics: three XT3 circuit-breakers, three-pole configuration, plug-in execution, vertical mounting orientation and a nominal switchboard width of 600 mm. These requirements make the PVCX3707 a configuration-specific component for electrical engineers and panel builders designing modular distribution assemblies.

As part of the ABB System pro E Power product group, the PVCX3707 is intended for integration with compatible switchboard enclosure structures and circuit-breaker installation components. Its three-device arrangement is particularly relevant where multiple outgoing circuits require individual protection using compatible ABB SACE Tmax XT3 moulded-case circuit-breakers.

The ABB PVCX3707 XT3 plug-in installation kit provides a clearly identified solution for professional switchboard construction. Its manufacturer order code, 1STQ009149A0000, supports accurate product selection, purchasing, bill-of-materials preparation and compatible replacement identification.

Key Advantages

  • Three-device installation: Designed for a vertical arrangement incorporating three compatible ABB SACE Tmax XT3 circuit-breakers.
  • Dedicated 3-pole configuration: Specifically identified for three-pole XT3 circuit-breaker installations.
  • Plug-in execution: Intended for compatible XT3 plug-in mounting arrangements.
  • Vertical installation orientation: Supports the designated vertical circuit-breaker layout.
  • 600 mm nominal switchboard width: Specified for the corresponding ABB System pro E Power enclosure configuration.
  • Coordinated ABB system integration: Belongs to the System pro E Power modular switchboard accessory range.
  • Multiple outgoing circuit applications: Suitable for arrangements requiring three individually installed XT3 protective devices.
  • Configuration-specific selection: Helps distinguish the required kit from accessories intended for different device quantities or pole arrangements.
  • Professional panel-building solution: Relevant to industrial and commercial low-voltage distribution projects.
  • Accurate procurement reference: Identified by ABB model PVCX3707 and order code 1STQ009149A0000.
  • Maintenance identification: Supports replacement of the corresponding installation accessory in a compatible switchboard.

Key Features

  • ABB System pro E Power modular switchboard accessory.
  • PVCX3707 manufacturer model designation.
  • ABB manufacturer order code: 1STQ009149A0000.
  • Manufacturer designation: 3 XT3 KIT 3P PLUG IN VERT.W=600MM.
  • Designed for three ABB SACE Tmax XT3 circuit-breakers.
  • Specified for 3-pole circuit-breaker configurations.
  • Intended for plug-in circuit-breaker execution.
  • Designed for a vertical mounting arrangement.
  • Compatible with the specified 600 mm nominal switchboard width.
  • Supports the integration of multiple moulded-case circuit-breakers.
  • Designed for compatible ABB System pro E Power structures.
  • Suitable for low-voltage main distribution board applications.
  • Supports organised circuit-breaker installation within a modular assembly.
  • Requires confirmation of the selected XT3 devices and associated plug-in components.
  • Intended for installation in accordance with ABB technical documentation.

Designed for Three ABB SACE Tmax XT3 Plug-In Circuit-Breakers

The ABB PVCX3707 installation kit is specifically identified for an arrangement incorporating three ABB SACE Tmax XT3 moulded-case circuit-breakers. The XT3 frame belongs to ABB's SACE Tmax XT family, which is used in low-voltage power distribution applications requiring circuit protection and switching functionality.

The three-device configuration distinguishes the PVCX3707 from installation kits designed for one or two circuit-breakers. In a distribution switchboard, multiple protective devices may be required to supply separate outgoing feeders, individual equipment circuits or distinct sections of an electrical installation. A dedicated three-device kit supports the intended mechanical arrangement for compatible XT3 equipment.

The manufacturer designation explicitly specifies 3-pole XT3 circuit-breakers. Three-pole moulded-case circuit-breakers are commonly used for three-phase circuits, where protection and switching are required across the three phase conductors. The PVCX3707 should therefore be selected for the specified three-pole arrangement rather than assuming compatibility with four-pole alternatives.

Another essential characteristic is the plug-in execution. Plug-in circuit-breakers are designed to interface with compatible plug-in connection equipment, enabling the circuit-breaker to be fitted into its intended mounting arrangement. This differs from fixed and withdrawable circuit-breaker executions, which may require different installation accessories and connection structures.

The PVCX3707 should be selected only after confirming that all three intended XT3 devices have the correct frame, pole configuration and plug-in execution. The compatibility of associated bases, terminals, connectors and auxiliary equipment should also be checked against the relevant ABB technical documentation.

Vertical Circuit-Breaker Mounting for 600 mm Wide Switchboards

The vertical mounting orientation is a defining feature of the ABB PVCX3707. Within a modular low-voltage switchboard, the position and orientation of circuit-breakers influence the arrangement of mounting structures, electrical connections, cable routing and adjacent equipment.

The manufacturer's designation identifies a 600 mm nominal switchboard width. This is a compatibility dimension associated with the intended enclosure arrangement, not necessarily the overall physical width of the installation kit. Exact component dimensions, fixing positions and mounting clearances should be confirmed using ABB technical drawings.

The three-device vertical configuration is particularly relevant where the switchboard design calls for multiple XT3 circuit-breakers within the specified equipment section. The installation arrangement should be coordinated with the enclosure structure and the space needed for circuit-breaker operation, electrical connections and any required accessories.

Panel builders should also consider the thermal and electrical requirements of the complete assembly. Installing several protective devices within one section can influence conductor routing, ventilation and the arrangement of nearby equipment. These considerations must be addressed using the applicable ABB design and verification information.

The ABB PVCX3707 provides the designated installation configuration, but it does not independently establish the current-carrying capacity, short-circuit performance or temperature-rise characteristics of the completed switchboard.

Integration with ABB System pro E Power Distribution Assemblies

The ABB System pro E Power platform supports modular construction of low-voltage electrical switchboards. Compatible assemblies may incorporate enclosure frames, busbar systems, moulded-case circuit-breakers, internal segregation barriers, cable connection arrangements and dedicated mounting accessories.

The PVCX3707 is intended to support the mechanical installation of three compatible XT3 plug-in circuit-breakers within this coordinated system. It should be considered alongside the selected enclosure configuration, the circuit-breaker connection equipment and any associated structural or mounting components.

Using a manufacturer-designated kit helps maintain consistency between the switchboard design and the components used during assembly. The exact ABB order code, 1STQ009149A0000, should be included in technical schedules and procurement documentation to distinguish the PVCX3707 from other XT3 installation kits.

The accessory is not itself a protective circuit-breaker. Its purpose is associated with the installation of compatible devices, while the electrical protection characteristics depend on the selected XT3 circuit-breakers, their trip units and the overall electrical design.

Where a switchboard requires additional internal segregation, the appropriate barriers and structural components must be selected separately in accordance with the intended assembly configuration. The PVCX3707 does not independently establish a Form 2, Form 3 or Form 4 internal separation arrangement.

IEC/EN 61439 and Complete Switchboard Verification

Low-voltage switchboard assemblies are subject to relevant design and verification requirements under the IEC/EN 61439 series. These requirements address the performance of the complete assembly rather than treating an individual mechanical installation accessory as a complete electrical product.

When integrating the ABB PVCX3707, the switchboard manufacturer must consider the selected circuit-breakers, busbar connections, conductors, enclosure arrangement and applicable installation conditions. The completed assembly must satisfy the relevant requirements for its intended electrical ratings and operating environment.

The installation kit does not independently determine the rated operational current, rated insulation voltage, short-circuit withstand capability or ingress protection of the finished switchboard. These characteristics depend on the complete verified design.

Similarly, any internal segregation classification must be established by the complete arrangement of busbars, functional units, terminals and separation barriers. The PVCX3707 should therefore be treated as a dedicated circuit-breaker mounting accessory within the wider switchboard system.

Selecting and Installing the ABB PVCX3707

Before ordering the ABB PVCX3707, confirm that the intended electrical switchboard belongs to the System pro E Power range and incorporates the appropriate 600 mm nominal width configuration.

The installation must require three ABB SACE Tmax XT3 circuit-breakers in a vertical arrangement. Each selected circuit-breaker should be a compatible 3-pole plug-in execution, as specified by the manufacturer's designation.

The product should be ordered using ABB manufacturer code 1STQ009149A0000. This is particularly important when distinguishing the PVCX3707 from other installation kits intended for two devices, four-pole circuit-breakers, different XT frames or alternative mounting arrangements.

Before assembly, verify the kit's supplied components, mounting instructions, fixing requirements and compatibility with the intended plug-in bases and electrical connection equipment. The manufacturer's designation does not establish that the three circuit-breakers themselves are included in the kit.

Installation should be undertaken by appropriately qualified personnel in accordance with ABB's applicable assembly instructions. The completed switchboard must be verified as a whole to confirm its mechanical suitability and electrical performance.

Typical Applications

  • ABB System pro E Power low-voltage main distribution boards.
  • Vertical installation of three compatible ABB SACE Tmax XT3 circuit-breakers.
  • Three-pole XT3 plug-in circuit-breaker arrangements.
  • 600 mm nominal width System pro E Power switchboard configurations.
  • Multiple outgoing feeder protection arrangements.
  • Industrial electrical power distribution systems.
  • Commercial building low-voltage distribution boards.
  • Modular switchboard construction using ABB Tmax XT equipment.
  • OEM electrical panel manufacturing.
  • Electrical distribution installations in industrial facilities.
  • Professional moulded-case circuit-breaker integration projects.
  • Switchboard extensions using compatible XT3 plug-in devices.
  • Maintenance and refurbishment of existing System pro E Power assemblies.
  • Replacement of an identified ABB PVCX3707 installation kit.

Technical Specifications

Product group System pro E Power
Manufacturer order code 1STQ009149A0000
Product designation 3 XT3 KIT 3P PLUG IN VERT.W=600MM
Product type Circuit-breaker installation kit
Product category Electrical switchboard mounting accessories
Compatible circuit-breaker family ABB SACE Tmax XT
Compatible circuit-breaker frame XT3
Specified circuit-breaker quantity 3
Supported pole configuration 3-pole
Circuit-breaker execution Plug-in
Installation orientation Vertical
Nominal switchboard width 600 mm
Compatible switchboard system ABB System pro E Power
Primary function Installation of three compatible XT3 plug-in circuit-breakers
Application Low-voltage electrical distribution switchboards
Mounting arrangement Vertical circuit-breaker installation
Physical kit dimensions Confirm against the applicable ABB technical drawing
Material and finish Confirm against the ABB product datasheet
Kit contents Confirm against ABB assembly documentation
Net weight Confirm against the ABB product datasheet
Circuit-breakers included Not established by the supplied designation; verify package contents before ordering
Electrical ratings Determined by the selected circuit-breakers and complete switchboard assembly
Applicable assembly standard IEC/EN 61439, as relevant to the completed switchboard

Frequently Asked Questions

What is the ABB PVCX3707 used for?

The ABB PVCX3707 is an installation kit designed for a vertical arrangement of three compatible ABB SACE Tmax XT3 3-pole plug-in circuit-breakers within a 600 mm nominal width ABB System pro E Power switchboard configuration.

What is the ABB order code for the PVCX3707?

The official ABB manufacturer order code for the PVCX3707 is 1STQ009149A0000. This reference should be used when ordering or identifying the installation kit.

How many XT3 circuit-breakers is the ABB PVCX3707 designed to accommodate?

The manufacturer designation specifies an installation arrangement for three ABB SACE Tmax XT3 circuit-breakers. All three devices must be compatible with the required 3-pole plug-in execution and vertical mounting configuration.

Does the ABB PVCX3707 support 4-pole XT3 circuit-breakers?

The PVCX3707 is specifically designated for 3-pole XT3 circuit-breakers. Compatibility with 4-pole versions should not be assumed. A different ABB installation kit may be required for a four-pole arrangement.

What does 3 XT3 KIT 3P PLUG IN VERT.W=600MM mean?

The designation identifies a kit for three XT3 circuit-breakers, each with a 3-pole plug-in configuration, installed in a vertical arrangement within a switchboard having a 600 mm nominal width.

What is the difference between the ABB PVCX3707 and PVCX3607?

The PVCX3707 is specified for three 3-pole XT3 plug-in circuit-breakers, while the PVCX3607 is specified for two XT3 plug-in circuit-breakers in 3-pole or 4-pole configurations. Both are designated for vertical installation in a 600 mm nominal width System pro E Power arrangement.

Does the ABB PVCX3707 include three XT3 circuit-breakers?

The manufacturer designation describes an installation kit for three XT3 circuit-breakers, but it does not establish that the circuit-breakers themselves are supplied. Confirm the package contents and any required plug-in connection components before ordering.

Is the ABB PVCX3707 suitable for fixed or withdrawable XT3 circuit-breakers?

The PVCX3707 is specifically designated for plug-in XT3 circuit-breaker installations. Compatibility with fixed or withdrawable executions should not be assumed. Select the ABB installation kit specified for the required device execution.

Is the 600 mm measurement the physical width of the PVCX3707 kit?

Not necessarily. The 600 mm measurement identifies the nominal switchboard width associated with the intended installation configuration. The exact physical dimensions of the kit should be confirmed using the applicable ABB technical drawing.

Can the ABB PVCX3707 be used with XT1, XT2 or XT4 circuit-breakers?

The PVCX3707 is specifically identified for the ABB SACE Tmax XT3 frame. Compatibility with XT1, XT2, XT4 or other circuit-breaker frames should not be assumed. Use the manufacturer-designated kit for the selected circuit-breaker.

Does the ABB PVCX3707 determine the electrical rating of the switchboard?

No. The PVCX3707 is a circuit-breaker installation accessory. The rated current, breaking capacity, protection characteristics and other electrical performance requirements depend on the selected XT3 devices and the verified complete switchboard assembly.

What should be checked before installing the ABB PVCX3707?

Confirm the ABB System pro E Power enclosure configuration, 600 mm nominal width, requirement for three XT3 circuit-breakers, correct 3-pole plug-in execution and vertical mounting orientation. Verify the kit contents, fixing requirements and associated plug-in connection components against ABB's assembly documentation.

Trusted by Electrical Panel Builders Worldwide

ABB System pro E Power accessories support professional modular low-voltage switchboard construction for industrial and commercial power distribution. The ABB PVCX3707 XT3 plug-in vertical installation kit provides a dedicated solution for electrical engineers, switchboard manufacturers and panel builders integrating three compatible 3-pole ABB SACE Tmax XT3 circuit-breakers into a 600 mm nominal width System pro E Power switchboard arrangement.