Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB PVDE1262 (1STQ008485A0000) is a System Pro E Power installation kit for two compatible 3-pole or 4-pole Emax 2 E1.2 fixed air circuit breakers, designed for vertical mounting in an 800 mm-wide low-voltage switchgear compartment.
£427.01
The ABB PVDE1262 (1STQ008485A0000) is a dedicated installation kit for two ABB Emax 2 E1.2 fixed air circuit breakers, designed for integration into ABB System Pro E Power low-voltage electrical distribution assemblies. Specified for 3-pole and 4-pole circuit breaker configurations, the kit supports vertical installation within an 800 mm-wide switchgear compartment.
As part of the ABB System Pro E Power product range, the PVDE1262 provides a purpose-designed installation arrangement for compatible ABB Emax 2 E1.2 air circuit breakers (ACBs). Its two-breaker configuration supports the positioning of two protective devices within the specified switchgear structure, while the fixed mounting design accommodates circuit breakers intended to remain secured in their designated installation positions.
Combining two ABB Emax 2 E1.2 breaker positions, 3-pole or 4-pole compatibility, fixed installation and a vertical mounting orientation, the ABB PVDE1262 offers a dedicated solution for professional switchboard manufacturers. Its 800 mm nominal compartment width makes it suitable for the specified System Pro E Power modular enclosure configuration.
The ABB PVDE1262 provides a dedicated installation arrangement for two compatible ABB Emax 2 E1.2 fixed air circuit breakers. Emax 2 air circuit breakers are used in low-voltage electrical distribution systems to provide switching and circuit protection functions according to the selected breaker models, trip units and electrical installation. The PVDE1262 supports the specified 3-pole or 4-pole configuration, allowing panel builders to plan the appropriate protective device arrangement for the completed switchboard.
A fixed air circuit breaker installation uses a breaker secured in its designated mounting position rather than a withdrawable configuration. The PVDE1262 is designed for vertical installation within an 800 mm nominal-width compartment, providing a specified mounting arrangement for two compatible E1.2 breakers. During switchboard design, the positioning of both circuit breakers must be coordinated with the required electrical connections, operating access, installation clearances and other applicable assembly requirements.
The ABB System Pro E Power platform supports modular low-voltage switchboard construction, including assemblies designed in accordance with IEC 61439-2. When selecting the PVDE1262, panel builders should verify the exact E1.2 breaker versions, pole configurations, mounting arrangements and associated electrical connections against the applicable ABB documentation. The PVDE1262 is an installation accessory; the supplied specification does not establish that the air circuit breakers, electrical connection components or other switchgear accessories are included.
| Product group | System Pro E Power |
|---|---|
| Product designation | PVDE1262 |
| ABB order code | 1STQ008485A0000 |
| Part number | 1STQ008485A0000 |
| Product type | Fixed air circuit breaker installation kit |
| Compatible circuit breaker range | ABB Emax 2 |
| Compatible circuit breaker frame | E1.2 |
| Number of circuit breaker positions | 2 |
| Pole configuration | 3-pole / 4-pole |
| Circuit breaker installation type | Fixed |
| Mounting orientation | Vertical |
| Nominal compartment width | 800 mm |
| Compatible enclosure system | ABB System Pro E Power |
| Application | Low-voltage switchgear and electrical distribution assemblies |
The ABB PVDE1262 is an installation kit for two compatible ABB Emax 2 E1.2 fixed air circuit breakers. It supports 3-pole or 4-pole configurations and is designed for vertical mounting within an 800 mm-wide ABB System Pro E Power switchgear compartment.
The PVDE1262 is specified for two ABB Emax 2 E1.2 air circuit breakers. Both breakers must be compatible with the designated fixed installation arrangement, pole configuration and complete System Pro E Power switchgear assembly.
Yes. The product specification identifies compatibility with 3-pole and 4-pole ABB Emax 2 E1.2 fixed air circuit breakers. The exact breaker versions and associated mounting and connection components should be verified against the applicable ABB documentation before installation.
The supplied specification identifies the PVDE1262 as an installation kit and does not confirm that the two Emax 2 E1.2 air circuit breakers or associated electrical connection accessories are included. These components should be specified separately and verified against the required switchgear configuration.
The PVDE1262 is specified for vertical installation within a compatible ABB System Pro E Power switchgear compartment with an 800 mm nominal width. The complete mounting arrangement should be checked against the relevant ABB installation instructions.
ABB System Pro E Power supports modular low-voltage switchgear construction for professional electrical distribution applications. The ABB PVDE1262 (1STQ008485A0000) provides a dedicated vertical installation solution for two compatible ABB Emax 2 E1.2 3-pole or 4-pole fixed air circuit breakers within an 800 mm-wide switchgear compartment, supporting accurate component selection and organised panel assembly.