1STQ008002A0000 ABB PVCT5428 T5 4-Pole Plug-In + 400 A RCD Vertical Installation Kit 600 mm

1STQ008002A0000 ABB PVCT5428 T5 4-Pole Plug-In + 400 A RCD Vertical Installation Kit 600 mm

ABB PVCT5428 (1STQ008002A0000) is a System pro E Power vertical installation kit for a 4-pole plug-in Tmax T5 moulded case circuit-breaker with a compatible 400 A RCD arrangement in a 600 mm wide low-voltage switchboard.

SKU: 1STQ008002A0000Alt SKU: PVCT5428MPN: 1STQ008002A0000
Price
List Price £168.27 ex VAT
Your Price (ex VAT)
£168.27
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £168.27
Trade pricing is personalised to your account

Manufacturer Lead Time

£168.27

Why Choose the ABB PVCT5428 T5 Plug-In and RCD Vertical Installation Kit?

The ABB PVCT5428 (1STQ008002A0000) is a dedicated vertical installation kit for ABB Tmax T5 plug-in moulded case circuit-breakers (MCCBs) with residual current protection equipment. Designed for a 4-pole plug-in circuit-breaker and 400 A RCD configuration, this accessory forms part of the ABB System pro E Power switchboard range and provides a purpose-designed mechanical mounting solution for professional low-voltage electrical distribution assemblies.

Developed for electrical panel builders, switchboard manufacturers and industrial electrical contractors, the PVCT5428 supports the organised installation of compatible Tmax T5 circuit-breakers together with associated residual current protection equipment. Its plug-in arrangement is suitable for switchboard designs where equipment accessibility and planned circuit-breaker replacement are important considerations, while its vertical installation orientation supports consistent component positioning within modular distribution panels.

Designed for 600 mm wide ABB System pro E Power switchboard configurations, the PVCT5428 accommodates a 4-pole Tmax T5 plug-in circuit-breaker with a compatible 400 A RCD arrangement. This dedicated mounting accessory provides a practical solution for commercial and industrial electrical distribution systems requiring coordinated circuit-breaker installation, residual current protection integration and an organised switchboard layout.

Key Advantages

  • Purpose-designed vertical installation kit for ABB Tmax T5 circuit-breakers with RCD equipment.
  • Compatible with 4-pole plug-in MCCB configurations.
  • Designed for an associated 400 A residual current protection arrangement.
  • Suitable for 600 mm wide ABB System pro E Power switchboards.
  • Plug-in circuit-breaker compatibility supports planned maintenance and equipment replacement when used with the appropriate connection components.
  • Vertical mounting orientation helps maintain organised electrical distribution compartments.
  • Dedicated mechanical installation arrangement supports consistent positioning of compatible circuit-breaker and RCD equipment.
  • Supports standardised switchboard construction using coordinated ABB components.
  • Suitable for professional commercial and industrial low-voltage distribution applications.

Key Features

  • ABB System pro E Power switchboard installation accessory.
  • PVCT5428 manufacturer product designation.
  • 1STQ008002A0000 ABB order code.
  • Designed for the ABB Tmax T5 MCCB series.
  • Supports a 4-pole circuit-breaker configuration.
  • Suitable for plug-in circuit-breaker execution.
  • Designed for integration with compatible 400 A RCD equipment.
  • Vertical installation orientation.
  • 600 mm nominal switchboard width.
  • Dedicated mechanical mounting solution for compatible T5 plug-in and RCD assemblies.
  • Designed for integration into modular low-voltage switchboard structures.
  • Supports organised positioning of circuit protection and residual current protection equipment.
  • Part of the ABB System pro E Power installation accessory range.
  • Suitable for professional electrical panel building and distribution board construction.

Reliable Plug-In Circuit-Breaker and RCD Integration for Low-Voltage Switchboards

The ABB PVCT5428 provides a dedicated mechanical installation solution for a 4-pole ABB Tmax T5 plug-in moulded case circuit-breaker with compatible 400 A residual current protection equipment. Its vertical mounting configuration is designed for a 600 mm wide System pro E Power switchboard arrangement, helping electrical panel manufacturers achieve consistent equipment positioning and an organised electrical distribution layout.

Plug-in MCCB arrangements are commonly selected for low-voltage distribution systems where maintenance accessibility and planned equipment replacement are important considerations. When combined with a correctly selected ABB Tmax T5 circuit-breaker, compatible plug-in connection components and suitable RCD equipment, the PVCT5428 supports switchboard designs incorporating overcurrent and residual current protection. The plug-in configuration allows compatible circuit-breaker equipment to be separated from its connection base in accordance with the manufacturer's specified isolation and maintenance procedures.

The 400 A RCD designation identifies the residual current protection configuration associated with this installation kit. It does not establish the rated current of every compatible circuit-breaker or specify the residual current tripping sensitivity. The actual electrical protection characteristics depend on the separately selected circuit-breaker and RCD equipment, including their rated currents, breaking capacities, residual current settings and operating characteristics.

The PVCT5428 is a mechanical installation accessory rather than a complete circuit-breaker or residual current protection device. The correct Tmax T5 circuit-breaker, plug-in connection arrangement and RCD combination must be verified against applicable ABB compatibility and installation documentation. The completed switchboard assembly must also comply with relevant electrical installation requirements and applicable low-voltage switchgear assembly standards, including IEC/EN 61439 where relevant.

Typical Applications

  • Industrial low-voltage main distribution switchboards.
  • ABB System pro E Power electrical panel assemblies.
  • Plug-in Tmax T5 circuit-breaker installations incorporating RCD equipment.
  • Commercial building electrical distribution systems.
  • Manufacturing plant power distribution panels.
  • Electrical feeder protection and distribution assemblies.
  • Industrial machinery and equipment power distribution.
  • Low-voltage distribution panels requiring residual current protection.
  • Electrical assemblies using compatible 400 A RCD configurations.
  • OEM switchboard manufacturing and electrical panel building.
  • Modular electrical distribution board construction.
  • Compatible switchboard refurbishment and protective equipment installation projects.

Technical Specifications

Product group System pro E Power
Series System pro E Power Installation Accessories
ABB order code 1STQ008002A0000
Manufacturer designation T5 KIT 4P PLUG IN+RCD(400A)VER.W=600MM
Product type Circuit-breaker and RCD installation kit
Accessory category Vertical MCCB mounting kit
Compatible circuit-breaker series ABB Tmax T5
Supported pole configuration 4-pole
Circuit-breaker execution Plug-in
Associated protection equipment Compatible residual current device (RCD)
RCD configuration designation 400 A
Installation orientation Vertical
Nominal switchboard width 600 mm
Compatible switchboard system ABB System pro E Power
Mounting application Electrical switchboard / panel installation
Suitable equipment Modular low-voltage distribution boards
Accessory function Mechanical installation of a compatible plug-in T5 circuit-breaker and 400 A RCD arrangement
Application category Low-voltage electrical power distribution

Frequently Asked Questions

What is the ABB PVCT5428 used for?

The ABB PVCT5428 is a vertical installation kit designed to mount a compatible 4-pole ABB Tmax T5 plug-in moulded case circuit-breaker with an associated 400 A RCD arrangement inside an ABB System pro E Power low-voltage switchboard.

Which circuit-breaker configuration is compatible with the PVCT5428?

The kit is specified for a 4-pole ABB Tmax T5 plug-in circuit-breaker with compatible residual current protection equipment. The appropriate circuit-breaker version, plug-in connection components and RCD must be selected according to ABB compatibility requirements.

What switchboard width does the ABB PVCT5428 support?

The PVCT5428 is designed for a 600 mm wide ABB System pro E Power switchboard arrangement with vertical circuit-breaker installation.

What does RCD(400A) mean in the PVCT5428 product designation?

RCD(400A) identifies the 400 A residual current protection configuration associated with the installation kit. It does not indicate the RCD's residual current tripping sensitivity, which is specified separately for the selected protective device. The circuit-breaker's electrical ratings must also be verified independently.

Does the ABB PVCT5428 include the Tmax T5 circuit-breaker and RCD?

The PVCT5428 is a mechanical installation kit, not a complete protective switching assembly. The compatible ABB Tmax T5 circuit-breaker, RCD, plug-in connection components and any required electrical accessories should be specified separately unless expressly included in a supplier's package.

Trusted by Electrical Panel Builders Worldwide

ABB System pro E Power installation accessories provide coordinated mechanical solutions for professional low-voltage switchboard construction. The PVCT5428 supports the vertical installation of a compatible 4-pole plug-in Tmax T5 circuit-breaker with a 400 A RCD arrangement within a 600 mm wide switchboard configuration, helping electrical panel builders create organised, serviceable and dependable power distribution assemblies.