Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1STQ007163B0000 System Pro E Power installation kit for three compatible three-pole or four-pole Tmax XT5 withdrawable motorised circuit-breaker positions, designed for vertical mounting in a 1000 mm nominal width switchboard.
£333.25
The ABB 1STQ007163B0000 is a dedicated three-position XT5 withdrawable motorised circuit-breaker installation kit designed for compatible ABB Tmax XT5 moulded case circuit-breaker arrangements within the ABB System Pro E Power modular switchboard system. This original ABB accessory supports the integration of multiple compatible circuit-breaker installations into professional low-voltage electrical distribution assemblies.
Identified by ABB as 3 XT5 KIT 3-4P WITH. MOT VERT.W=1000MM, the product is specified for an arrangement involving three XT5 installation positions, compatible three-pole or four-pole circuit breakers, a withdrawable mounting configuration and motorised operation compatibility. The manufacturer also specifies a vertical installation orientation and a 1000 mm nominal switchboard width.
Part of the ABB System Pro E Power range, the 1STQ007163B0000 is intended for switchboard manufacturers, electrical panel builders and engineers planning multi-breaker distribution assemblies. Its dedicated configuration helps identify the appropriate installation arrangement where three compatible XT5 positions are required within a coordinated ABB modular switchboard structure.
The ABB Tmax XT5 family comprises moulded case circuit breakers used in low-voltage electrical distribution systems. Depending on the selected breaker version and accessories, XT5 equipment can be incorporated into fixed, plug-in or withdrawable installation arrangements to meet different mechanical and operational requirements.
The ABB 1STQ007163B0000 is distinguished by the manufacturer's 3 XT5 KIT designation. This identifies a kit configuration associated with three XT5 installation positions, making it relevant to compatible switchboard layouts where multiple circuit-breaker arrangements must be accommodated within the specified cabinet width.
The three-pole or four-pole compatibility allows the kit to be considered for suitable XT5 circuit-breaker configurations. The exact combination of breakers, their individual dimensions and any restrictions on mixing pole configurations must be checked against ABB's assembly documentation before installation.
The withdrawable designation identifies a circuit-breaker mounting arrangement intended for compatible withdrawal equipment. When correctly configured, a withdrawable system provides the mechanical and electrical interfaces necessary for the operating positions permitted by its design. This can support maintenance planning and equipment accessibility, subject to the manufacturer's safety and operating procedures.
The motorised designation identifies compatibility with suitable motor-operated circuit-breaker arrangements. Depending on the selected XT5 equipment and separately required accessories, motorised operation may be incorporated into a wider electrical distribution or control system. The installation kit itself should not be assumed to contain the motor operators or provide electrically operated switching independently.
The specified vertical mounting orientation is an important mechanical parameter. The 1STQ007163B0000 is intended for the corresponding vertical XT5 arrangement within a compatible System Pro E Power switchboard, rather than a horizontal mounting configuration.
The 1000 mm nominal switchboard width identifies the intended cabinet configuration. It should not be interpreted as the physical width of the supplied components or as confirmation of the available compartment height, depth or individual circuit-breaker clearances. These dimensions must be verified against the complete ABB switchboard design.
Unlike XT5 installation accessories that explicitly identify a current class in their manufacturer designation, the supplied description for 1STQ007163B0000 does not state a current rating. The applicable circuit-breaker ratings and completed assembly current-carrying capability must therefore be established from the selected equipment and relevant ABB technical documentation.
As an installation accessory kit, the 1STQ007163B0000 should not be treated as a complete three-breaker distribution assembly. The inclusion of circuit breakers, motor operators, withdrawal mechanisms, connection components and other mechanical or electrical accessories must be confirmed from ABB's supplied-content information.
| Product group | System Pro E Power |
|---|---|
| ABB order code | 1STQ007163B0000 |
| Manufacturer designation | 3 XT5 KIT 3-4P WITH. MOT VERT.W=1000MM |
| Product type | Multiple XT5 withdrawable motorised circuit-breaker installation kit |
| Product category | Circuit-breaker mounting and installation accessories |
| Compatible circuit-breaker family | ABB Tmax XT5 |
| Designated XT5 installation positions | 3 |
| Pole configuration | 3-pole / 4-pole |
| Installation version | Withdrawable |
| Operating mechanism configuration | Motorised |
| Mounting orientation | Vertical |
| Nominal switchboard width | 1000 mm |
| Compatible switchboard system | ABB System Pro E Power |
| Primary application | Low-voltage electrical distribution assemblies |
| Equipment classification | Switchboard installation accessory |
| Supplied circuit breakers | Inclusion not confirmed by the manufacturer designation |
The ABB 1STQ007163B0000 is a System Pro E Power installation kit designated for three compatible ABB Tmax XT5 circuit-breaker positions in a withdrawable, motorised and vertical arrangement within a 1000 mm nominal width switchboard configuration.
The manufacturer's 3 XT5 KIT designation identifies an arrangement associated with three XT5 installation positions. The exact permitted breaker combinations, compartment layout and supplied mounting components must be confirmed using ABB's technical documentation.
WITH. identifies a withdrawable circuit-breaker configuration, MOT identifies compatibility with a motorised operating arrangement, and VERT. specifies vertical installation. These designations describe the intended configuration and do not independently confirm which operating or withdrawal accessories are supplied.
The ABB 1STQ007163B0000 is designated for compatible three-pole or four-pole ABB Tmax XT5 circuit breakers and a 1000 mm nominal switchboard width. The manufacturer designation does not specify a current rating, so electrical compatibility must be verified separately.
The ABB 1STQ007163B0000 is identified as a circuit-breaker installation accessory kit, not a complete three-breaker assembly. The inclusion of XT5 circuit breakers, motor operators, withdrawal mechanisms or other accessories should not be assumed. Confirm the supplied contents and separately required components against ABB's product documentation.
ABB System Pro E Power accessories support coordinated, modular and maintainable low-voltage electrical switchboard construction. The 1STQ007163B0000 provides a dedicated installation configuration for three compatible ABB Tmax XT5 withdrawable motorised circuit-breaker positions, supporting three-pole or four-pole arrangements with vertical mounting in a 1000 mm nominal width switchboard.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.