Rittal SK3313.420 LCP Rack DX is a 12 kW direct-expansion rack cooling system measuring 300 × 2000 × 1200 mm with 3–12 kW modulation, four EC fans, 380–480 V three-phase 50/60 Hz operation, IP40 protection and integrated SNMP monitoring.
£12,874.09
The Rittal SK3313.420 LCP Rack DX is a high-performance direct-expansion rack cooling system designed for precise thermal management of one or two IT racks. Delivering up to 12 kW cooling output, it combines an integrated air/refrigerant heat exchanger with an inverter-controlled compressor to provide demand-based cooling for servers, storage systems and network equipment.
The cooling output is continuously adjustable across a 3–12 kW modulation range, allowing the system to respond efficiently as IT heat loads change. Four energy-efficient EC fan modules provide up to 4,800 m³/h of unimpeded airflow, while redundant air-side temperature sensing and control of the server inlet temperature support dependable operating conditions for critical equipment.
Measuring 300 mm wide × 2000 mm high × 1200 mm deep, the SK3313.420 is designed for flush installation alongside compatible Rittal VX IT enclosures. It operates from a 380–480 V AC three-phase, 50/60 Hz supply, includes an integrated SNMP card for Ethernet monitoring and requires an external condenser to transfer absorbed heat away from the installation room.
Modern servers, storage arrays and network equipment can generate concentrated heat loads that are difficult to manage using room-level cooling alone. The Rittal SK3313.420 is installed directly alongside the server rack, drawing warm exhaust air from the rear, cooling it through the integrated air/refrigerant heat exchanger and supplying conditioned air towards the front of the 482.6 mm (19") equipment level across the height of the enclosure.
Four EC fans and an inverter-controlled compressor allow cooling performance to adapt continuously between 3 and 12 kW. The absorbed thermal energy is transferred to an external condenser rather than discharged into the data centre room, while integrated SNMP monitoring provides access to operating parameters and alarms over Ethernet for integration into professional IT infrastructure management systems.
Tick the specs you need, then view products that match.
| Device Type | Wall / door-mounted cooling unit | |
|---|---|---|
| Refrigerant Type | R410A | |
| Coil / Supply Voltage | 380–480 V AC, 3-phase | |
| IP Rating | IP40 | |
| Voltage | 380-480 V AC | |
| Cooling Output (W) | 12000 W | |
| Manufacturer | Rittal | |
| Series | Liquid Cooling Package LCP Rack DX | |
| Model | SK3313.420 | |
| Alternative article number | 3313420 | |
| Product type | Direct-expansion rack cooling unit | |
| Design | Rack cooling | |
| Maximum cooling output | 12 kW | |
| Useful cooling output L22/L35 | 12 kW | |
| Useful cooling output L22/L45 | 10 kW | |
| Cooling modulation range | 3–12 kW | |
| Number of fan modules | 4 | |
| Fan technology | EC | |
| Maximum air throughput at 50 Hz | 4,800 m³/h | |
| Rated operating voltage | 380–480 V AC, 3~, 50/60 Hz | |
| Maximum rated current | 7.5 A | |
| Start-up current | 11 A | |
| Maximum connected load | 4.7 kW | |
| Recommended pre-fuse | 20 A | |
| Electrical connection | Connection clamp | |
| Duty cycle | 100% | |
| Temperature control | Continuously variable fan control and inverter-controlled compressor | |
| Refrigerant | R410A | |
| Maximum refrigerant connection length | 45 m | |
| Operating temperature range | 5–35 °C | |
| Storage temperature range | -20–50 °C | |
| Sound pressure level at 50 Hz | 68 dB(A) | |
| Colour | RAL 7035 | |
| Monitoring | SNMP over Ethernet | |
| Suitable enclosure type | VX IT | |
| Installation in bayed enclosure suite | Flush | |
| Width | 300 mm | |
| Height | 2000 mm | |
| Depth | 1200 mm | |
| Dimensions (W × H × D) | 300 × 2000 × 1200 mm | |
| Net weight | 213 kg | |
| Gross weight | 224 kg | |
| Pack quantity | 1 pc | |
| EAN | 4028177953840 | |
| Customs tariff number | 84186900 | |
| ETIM 9 | EC002515 | |
| ECLASS 8.0 | 27180712 |
The Rittal SK3313.420 LCP Rack DX provides up to 12 kW cooling output and continuously adjusts its performance across a 3–12 kW modulation range to match changing IT heat loads.
The LCP Rack DX measures 300 mm wide × 2000 mm high × 1200 mm deep and is designed for flush integration alongside compatible Rittal VX IT enclosures.
The unit operates from a 380–480 V AC three-phase supply at 50/60 Hz, with a maximum rated current of 7.5 A and a recommended 20 A pre-fuse.
Yes. An integrated SNMP card provides direct Ethernet connectivity for monitoring and alarm management, allowing the cooling system to be integrated into compatible IT infrastructure management platforms.
Yes. The LCP Rack DX is a split direct-expansion cooling system and requires a suitable external condenser to reject the heat removed from the IT equipment. The refrigeration circuit is charged with R410A following installation and commissioning.
Rittal LCP Rack DX solutions combine inverter-controlled direct-expansion cooling, efficient EC fan technology and integrated network monitoring to provide precise, demand-based thermal management for critical server, storage and network infrastructure.