Rittal SK3311.430 LCP Inline DX is a 12 kW refrigerant-based row cooling unit with 3–12 kW modulation, EC fans and three-phase 400 V 50 Hz or 380–480 V 60 Hz operation for small and medium-sized IT installations.
The Rittal SK3311.430 LCP Inline DX is a high-performance refrigerant-based split cooling system for IT rack rows, designed for efficient thermal management of small and medium-sized data centre installations. Delivering up to 12 kW cooling output, the unit is installed alongside compatible server racks and supports the front-to-back airflow principle used by modern 482.6 mm (19") IT equipment.
The LCP Inline DX draws warm server exhaust air from the rear aisle, cools it through its integrated air/refrigerant heat exchanger and returns conditioned air to the room or cold aisle. Its inverter-controlled compressor continuously adapts cooling output between approximately 3–12 kW according to actual demand, while four efficient EC fan modules provide up to 4,800 m³/h of unimpeded airflow at 50 Hz.
Designed for flush installation within a bayed TS IT enclosure suite, the SK3311.430 measures 300 mm wide × 2000 mm high × 1000 mm deep. It operates from a 400 V three-phase 50 Hz supply or 380–480 V three-phase 60 Hz supply and provides IP20 protection. An external condenser is required to complete the refrigerant circuit and reject absorbed thermal energy outside the installation room.
High-density servers and network equipment generate concentrated heat loads that require controlled cooling directly alongside the rack row. The Rittal LCP Inline DX uses front-to-back airflow, drawing heated air from the rear of the IT equipment and returning cooled air towards the cold aisle. This targeted approach helps minimise unwanted mixing between hot and cold air while maintaining suitable server inlet temperatures.
The SK3311.430 combines four EC fans with an inverter-controlled compressor to adapt cooling performance continuously to actual IT demand. Because the cooling unit is physically separated from the server enclosures, maintenance can be performed without unnecessarily disturbing installed IT equipment. The split-system design transfers absorbed heat to an external condenser, preventing that thermal energy from being released back into the data centre room.
Tick the specs you need, then view products that match.
| Device Type | Wall / door-mounted cooling unit | |
|---|---|---|
| Coil / Supply Voltage | 380–480 V AC, 3-phase | |
| IP Rating | IP20 | |
| Voltage | 380-480 V AC | |
| Cooling Output (W) | 12000 W | |
| Manufacturer | Rittal | |
| Series | LCP Inline DX | |
| Model | SK3311.430 | |
| Alternative article number | 3311430 | |
| Product type | Refrigerant-based split IT cooling unit | |
| Cooling configuration | Row / suite cooling | |
| Maximum cooling output | 12 kW | |
| Useful cooling output L30/L22 | 12 kW | |
| Useful cooling output L22/L45 | 10 kW | |
| Cooling modulation range | 3–12 kW | |
| Number of fan modules | 4 | |
| Fan technology | EC | |
| Air throughput at 50 Hz | 4,800 m³/h | |
| Rated operating voltage at 50 Hz | 400 V AC, 3~ | |
| Rated operating voltage at 60 Hz | 380–480 V AC, 3~ | |
| Maximum rated current at 50 Hz | 7.5 A | |
| Recommended pre-fuse | 20 A | |
| Duty cycle | 100% | |
| Electrical connection | Connection clamp | |
| Cooling medium | Refrigerant | |
| Temperature control | Infinitely variable fan control / inverter-controlled compressor | |
| Operating temperature range | 15–35 °C | |
| Storage temperature range | -20–50 °C | |
| Noise pressure level at 50 Hz | 69 dB(A) | |
| Installation | Flush within bayed enclosure suite | |
| Suitable enclosure system | TS IT | |
| Width | 300 mm | |
| Height | 2000 mm | |
| Depth | 1000 mm | |
| Dimensions (W × H × D) | 300 × 2000 × 1000 mm | |
| Net weight | 181 kg | |
| Gross weight | 224 kg | |
| EAN | 4028177691339 |
The Rittal SK3311.430 is a 12 kW row-based IT cooling unit designed to cool server and network equipment in small and medium-sized data centres and compatible Rittal TS IT enclosure suites.
The LCP Inline DX provides up to 12 kW cooling output and can continuously modulate its cooling performance across a range of approximately 3–12 kW.
The unit operates from 400 V AC three-phase at 50 Hz or 380–480 V AC three-phase at 60 Hz.
The four EC fan modules provide an unimpeded airflow of approximately 4,800 m³/h at 50 Hz, supporting efficient front-to-back cooling of IT equipment.
Yes. The LCP Inline DX is a refrigerant-based split cooling system and requires a suitable external condenser to reject the heat absorbed from the IT environment.
Rittal LCP cooling systems provide targeted thermal management for critical IT infrastructure, combining efficient EC fan technology, demand-based cooling control and rack-oriented airflow management to support reliable data centre operation.