NVENT HOFFMAN T430616G102 T-Series outdoor-SS 1958W,115V

NVENT HOFFMAN T430616G102 T-Series outdoor-SS 1958W,115V

nVent HOFFMAN T-Series T430616G102 outdoor stainless steel enclosure air conditioner with 1958 W nominal cooling capacity at 60 Hz, 115 V AC supply and dimensions of 1092 x 400 x 279 mm.

SKU: T430616G102MPN: T430616G102
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the nVent HOFFMAN T430616G102 T-Series Outdoor Cooling Unit?

The nVent HOFFMAN T430616G102 is a robust T-Series outdoor enclosure air conditioner designed to provide active thermal management for electrical and electronic equipment installed in outdoor enclosures. With a nominal cooling capacity of 1958 W and a 115 V AC supply, it helps maintain suitable internal enclosure temperatures and protect sensitive components from excessive heat.

The T-Series T43 design combines a compact footprint with rugged outdoor construction. The stainless steel version provides enhanced corrosion resistance and is designed for demanding factory and outdoor environments, with enclosure protection suitable for Type 12, 3R and 4 applications and Type 4X stainless steel construction.

With dimensions of 1092 mm high × 400 mm wide × 279 mm deep, the T430616G102 provides substantial cooling performance in a purpose-built enclosure cooling package. It is designed to operate across an outdoor ambient temperature range of -40 °C to +55 °C, making it suitable for demanding industrial installations.

Key Advantages

  • Purpose-designed nVent HOFFMAN T-Series T43 outdoor enclosure air conditioner.
  • 1958 W nominal cooling capacity at 60 Hz.
  • Designed for a 115 V AC nominal supply, with a 100–115 V AC operating range.
  • Stainless steel construction for corrosion-resistant outdoor applications.
  • Designed for demanding environments with an operating range of -40 °C to +55 °C.
  • UL/cUL listed outdoor design with Type 12, 3R and 4 protection, with Type 4X stainless steel construction.

Key Features

  • nVent HOFFMAN T-Series T43 outdoor cooling unit.
  • 1958 W nominal cooling capacity at 60 Hz.
  • 6310 / 6680 BTU/h nominal cooling capacity at 50 / 60 Hz.
  • 115 V AC rated voltage.
  • 100–115 V AC operating range.
  • R-134A refrigerant.
  • Basic mechanical thermostat for enclosure temperature control.
  • Dual condenser-side air movers for performance redundancy.
  • Cleanable, reusable aluminium mesh filter.
  • Compressor heater and head pressure control for outdoor operation.
  • Easy-mount flanges for straightforward installation.

Reliable Thermal Management for Outdoor Enclosures

The nVent HOFFMAN T430616G102 actively removes heat from sealed electrical enclosures to help maintain an appropriate operating temperature for control electronics, automation hardware and electrical equipment. The separate internal and external air circuits prevent the conditioned enclosure air from mixing with ambient air, making the air conditioner suitable for sealed enclosure applications.

The T43 T-Series incorporates corrosion-resistant components, compressor heating and head pressure control to support reliable outdoor operation. Its dual condenser-side air movers provide performance redundancy, while the reusable aluminium mesh filter helps protect the cooling system and maintain performance.

Typical Applications

  • Outdoor electrical control panels.
  • Industrial automation enclosures.
  • Electrical distribution and switchgear enclosures.
  • Outdoor machine control systems.
  • Telecommunications and electronic equipment enclosures.
  • Factory and process-control installations.
  • Industrial applications requiring corrosion-resistant active enclosure cooling.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Wall / door-mounted cooling unit
Refrigerant Type R134a
Coil / Supply Voltage 115 V AC, 1-phase
Mounting Type Recessed
Voltage 115 V AC
Cooling Output (W) 1958 W
Manufacturer nVent HOFFMAN
Series T-Series
Model T430616G102
Product type Outdoor enclosure air conditioner
Model family T43
Nominal cooling capacity 1958 W at 60 Hz
Rated voltage 115 V AC
Operating voltage 100–115 V AC
Frequency 50 / 60 Hz
Refrigerant R-134A
Operating temperature range -40 °C to +55 °C
Height 1092 mm
Width 400 mm
Depth 279 mm
Construction Stainless steel
Enclosure protection UL Type 12, 3R and 4; Type 4X stainless steel
International protection IP56 internal loop / IP34 external loop
Control Basic mechanical thermostat
Weight approx. 57 kg
Mounting Exterior or fully recessed mounting options depending on configuration

Frequently Asked Questions

What is the nVent HOFFMAN T430616G102 used for?

The T430616G102 is an outdoor enclosure air conditioner designed to remove excess heat from sealed electrical and electronic enclosures and help maintain suitable internal operating temperatures.

What is the cooling capacity of the T430616G102?

The T430616G102 has a nominal cooling capacity of 1848 W at 50 Hz and 1958 W at 60 Hz.

What supply voltage does the T430616G102 require?

The T430616G102 is rated for 115 V AC and has an operating voltage range of 100–115 V AC.

Is the T430616G102 suitable for outdoor use?

Yes. The T430616G102 is a T-Series outdoor stainless steel cooling unit designed for demanding outdoor environments and an operating temperature range of -40 °C to +55 °C.

What are the dimensions of the T430616G102?

The cooling unit measures 1092 mm high × 400 mm wide × 279 mm deep.

Trusted by Industrial Enclosure Professionals

nVent HOFFMAN T-Series thermal management systems provide dependable active cooling for electrical and electronic equipment installed in demanding industrial and outdoor enclosure environments.