Finder 7F.21.8.120.4400 is a Size 4 reverse flow exhaust filter fan for industrial electrical enclosures featuring a 120 V AC 50/60 Hz supply, 400 m³/h nominal free-air airflow at 50 Hz, IP54 and UL Type 12 protection, snap-in mounting and a replaceable filter mat.
£202.22
The Finder 7F.21.8.120.4400 is a high-performance 120 V AC reverse flow filter fan designed for effective ventilation of industrial electrical cabinets, switchboards and automation control enclosures. Part of the Finder 7F Series, this Size 4 fan provides a nominal 400 m³/h free-air airflow at 50 Hz and is specifically configured to extract warm air from electrical enclosures.
Unlike conventional intake filter fans, the Finder 7F.21 reverse flow configuration is designed for exhaust ventilation. It draws warm air from inside an electrical cabinet and expels it through the fan assembly, helping remove heat generated by power supplies, variable frequency drives, contactors, relays and other electrical equipment.
Featuring a 120 V AC, 50/60 Hz supply, a robust Size 4 enclosure grille, an easily replaceable filter mat and IP54 / UL Type 12 protection when correctly installed, the Finder 7F.21.8.120.4400 provides a practical solution for thermal management in industrial automation panels. Its snap-in mounting system helps reduce installation time, while its grey RAL 7035 finish complements standard industrial electrical enclosures.
The Finder 7F.21.8.120.4400 is designed to improve ventilation in electrical enclosures by actively extracting heated air. Electrical equipment such as variable speed drives, transformers, power supplies, contactors and electronic control modules generates heat during operation. If this heat cannot escape, internal cabinet temperatures may rise and adversely affect component reliability.
The reverse flow design of the 7F.21 Series addresses this issue by moving air from the enclosure interior towards the outside environment. This makes the fan suitable for installations where an active exhaust arrangement is preferred, rather than a conventional filtered intake fan.
With a nominal free-air capacity of 400 m³/h at 50 Hz, the Finder 7F.21.8.120.4400 is designed for electrical cabinets requiring substantial airflow. At 60 Hz, its nominal free-air volume increases to approximately 445 m³/h.
Actual installed airflow will normally be lower than the free-air rating because filters, cabinet openings, internal equipment and other restrictions create resistance to airflow. Finder's published performance data indicates approximately 270 m³/h at 50 Hz and 300 m³/h at 60 Hz for a corresponding filtered enclosure ventilation arrangement.
For effective cabinet cooling, the fan should be installed as part of a properly designed ventilation system with a suitable make-up air opening or complementary filter assembly. The positioning of the inlet and outlet should encourage airflow across heat-generating equipment rather than allowing air to bypass critical components.
The Finder 7F.21.8.120.4400 offers a high-volume ventilation solution for electrical panels containing components with significant heat dissipation. By promoting continuous air exchange, the fan can help reduce temperature build-up when the surrounding air is cooler than the air inside the enclosure.
The correct ventilation capacity depends on several factors, including the total heat dissipated by the installed equipment, the permitted internal cabinet temperature, the ambient temperature and the resistance created by filters and cabinet construction.
Airflow selection should be based on installed operating conditions rather than the free-air rating alone. A ventilation fan cannot cool an enclosure below the temperature of the incoming ambient air. Where ambient conditions are unsuitable or heat loads are excessive, an enclosure air conditioner or another cooling method may be necessary.
The fan's approximately 72 dB(A) noise level should also be considered during system design, particularly where electrical cabinets are installed close to occupied work areas. This is a high-airflow industrial ventilation device intended for applications where thermal performance is a primary requirement.
The Finder 7F.21.8.120.4400 incorporates a replaceable filter mat that can be serviced as part of routine enclosure maintenance. The filter helps manage airborne contaminants in the ventilation path and supports the protection of sensitive electrical equipment.
For this Size 4 fan, the corresponding replacement filter mat is the Finder 07F.45. Using the correctly specified filter material helps maintain the intended fit, airflow characteristics and enclosure protection performance.
Filter condition has a direct effect on ventilation performance. As airborne dust accumulates, the resistance to airflow increases, potentially reducing cooling effectiveness. Inspection and replacement intervals should therefore be based on the surrounding environment and the manufacturer's maintenance recommendations.
The fan's snap-in mounting arrangement and accessible filter construction are designed to reduce installation and servicing time. Maintenance should only be performed after following the relevant electrical isolation and safe working procedures.
The Finder 7F.21.8.120.4400 uses a Size 4 mounting format with an external grille measuring approximately 255 × 255 mm. It is designed for installation into a nominal 223 × 223 mm enclosure cut-out, with the exact cutting dimensions and tolerances specified in Finder's installation documentation.
The snap-in mounting system helps simplify installation into a prepared electrical enclosure panel. Push-in electrical terminals support efficient connection to the appropriate 120 V AC supply.
When installed according to the manufacturer's instructions, the assembly provides IP54 protection and is associated with a UL Type 12 enclosure protection classification. These ratings are relevant to protection against dust and water ingress, but they depend on correct installation and the overall enclosure design.
The RAL 7035 grey finish complements commonly used industrial cabinet colours, making the fan suitable for integration into standard electrical distribution and automation enclosures.
The Finder 7F.21.8.120.4400 is intended for indoor industrial enclosure ventilation. It should not be assumed suitable for outdoor exposure or aggressive environments without verifying the complete installation's environmental requirements.
Tick the specs you need, then view products that match.
| Cut-Out Size (mm) | 223 × 223 mm | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 7F Series | |
| Model | 7F.21.8.120.4400 | |
| Product type | Industrial enclosure filter fan | |
| Fan type | Reverse flow / exhaust filter fan | |
| Installation environment | Indoor electrical cabinets and control enclosures | |
| Airflow direction | From inside the enclosure to the outside | |
| Nominal supply voltage | 120 V AC | |
| Supply type | Alternating current | |
| Rated supply frequency | 50/60 Hz | |
| Nominal free-air airflow at 50 Hz | 400 m³/h | |
| Nominal free-air airflow at 60 Hz | 445 m³/h | |
| Approximate airflow with corresponding exhaust filter at 50 Hz | 270 m³/h | |
| Approximate airflow with corresponding exhaust filter at 60 Hz | 300 m³/h | |
| Fan quantity | 1 | |
| Fan size | Size 4 | |
| Front grille width | 255 mm | |
| Front grille height | 255 mm | |
| Overall assembly depth | Approximately 144 mm | |
| Nominal enclosure cut-out | 223 × 223 mm | |
| Cut-out tolerance | Refer to Finder's Size 4 mounting drawing | |
| Acoustic noise level | Approximately 72 dB(A) | |
| Fan service life | Approximately 50,000 hours at 40 °C under specified operating conditions | |
| Protection rating | IP54 when correctly installed | |
| Enclosure protection classification | UL Type 12 | |
| Mounting method | Snap-in panel mounting | |
| Electrical connection | Push-in terminals | |
| Housing colour | Grey | |
| RAL colour code | RAL 7035 | |
| Filter element | Replaceable filter mat | |
| Compatible replacement filter mat | Finder 07F.45 | |
| Compatible Size 4 exhaust filter | Finder 7F.02.0.000.4000 | |
| Airflow arrangement | Reverse flow exhaust | |
| Mounting location | Electrical enclosure sidewall or other manufacturer-approved panel position | |
| Country of manufacture | Italy |
The Finder 7F.21.8.120.4400 is a reverse flow filter fan designed to extract warm air from industrial electrical cabinets, switchboards and automation control enclosures. It helps manage internal temperatures by promoting forced-air ventilation.
The Finder 7F.21.8.120.4400 is a reverse flow exhaust fan. It is designed to move air from inside the electrical enclosure to the outside, unlike standard intake filter fans that draw ambient air into the cabinet.
The fan operates from a nominal 120 V AC supply at 50/60 Hz. It should be connected only to a suitable electrical supply in accordance with the manufacturer's installation instructions.
The fan provides a nominal free-air airflow of 400 m³/h at 50 Hz and approximately 445 m³/h at 60 Hz. Actual airflow will depend on the filters, enclosure arrangement and resistance within the ventilation system.
Finder's published performance data indicates approximately 270 m³/h at 50 Hz and 300 m³/h at 60 Hz with a corresponding exhaust filter installed in the cabinet ventilation arrangement.
The Finder 7F.21.8.120.4400 has an IP54 protection rating when correctly installed. It is also associated with a UL Type 12 enclosure protection classification for suitable indoor industrial applications.
The fan has a 255 × 255 mm front grille and an overall assembly depth of approximately 144 mm. It uses the Finder Size 4 mounting format.
The fan is designed for a nominal 223 × 223 mm enclosure cut-out. The manufacturer's Size 4 installation drawing should be consulted for the exact cutting tolerances and mounting requirements.
Yes. The fan uses an easily replaceable filter mat. The corresponding Finder Size 4 replacement filter mat is the 07F.45.
The fan uses a snap-in panel mounting system designed for installation into a correctly prepared electrical enclosure opening. It also features push-in electrical connections for the supply wiring.
Both models are 120 V AC Size 4 filter fans with a nominal 400 m³/h free-air rating at 50 Hz. The key difference is airflow direction: the 7F.21.8.120.4400 is a reverse flow exhaust version, while the 7F.20.8.120.4400 is the standard intake airflow version.
Both models are Size 4 reverse flow exhaust filter fans with the same nominal airflow class. The main difference is supply voltage: the 7F.21.8.120.4400 operates at 120 V AC, while the 7F.21.8.230.4400 operates at 230 V AC.
Finder 7F Series filter fans provide practical thermal management solutions for industrial electrical cabinets, switchboards and automation enclosures. With a 120 V AC supply, reverse flow exhaust operation, nominal 400 m³/h free-air airflow at 50 Hz, IP54 / UL Type 12 protection and a replaceable filter mat, the Finder 7F.21.8.120.4400 offers an effective ventilation option for electrical engineers, industrial panel builders, machine manufacturers and maintenance professionals.