Finder 7F.21.8.120.4400.0 is a black Size 4 reverse flow exhaust filter fan for industrial electrical enclosures featuring a 120 V AC supply, 400 m³/h nominal free-air airflow, 120 W power rating and UL Type 12 protection for high-volume cabinet ventilation.
£221.36
The Finder 7F.21.8.120.4400.0 is a high-performance 120 V AC reverse flow filter fan designed to extract warm air from industrial electrical cabinets, automation panels and machinery control enclosures. Part of the Finder 7F Series, this Size 4 ventilation fan combines high-volume exhaust airflow, robust industrial construction and a distinctive black housing for applications where both thermal performance and enclosure appearance are important.
With a nominal free-air capacity of 400 m³/h (approximately 262 CFM), the Finder 7F.21.8.120.4400.0 provides powerful forced-air ventilation for electrical enclosures containing heat-generating equipment. Its reverse flow configuration draws air from inside the cabinet and discharges it to the surrounding environment, helping remove accumulated heat from electrical and electronic components.
Designed for a 120 V AC supply, this industrial exhaust filter fan features a 120 W power rating, a Size 4 (10-inch class) mounting format and UL Type 12 enclosure protection when correctly installed. The black finish distinguishes this model from the standard-colour Finder 7F.21.8.120.4400, making it particularly suitable for black electrical cabinets, specialist machine enclosures and coordinated industrial equipment designs.
The Finder 7F.21.8.120.4400.0 is designed to remove heated air from industrial electrical enclosures using a reverse flow ventilation arrangement. Electrical equipment such as variable frequency drives, transformers, industrial power supplies, contactors and automation controllers generates heat during normal operation. Without adequate ventilation, this heat can accumulate inside the cabinet and increase the operating temperature of sensitive components.
The reverse flow design provides an active exhaust path, drawing air from the enclosure interior and expelling it into the surrounding environment. This differs from a standard intake filter fan, which draws outside air into the enclosure. Selecting the correct airflow direction is important when designing an effective electrical cabinet cooling system.
With a nominal 400 m³/h free-air rating, the fan is intended for installations requiring substantial airflow. The manufacturer's free-air rating represents the fan's performance under specified low-resistance conditions and should not be treated as the guaranteed airflow through a complete electrical cabinet.
In an installed system, airflow is affected by inlet openings, filter resistance, internal obstructions, cabinet geometry and the position of heat-generating equipment. The ventilation arrangement should therefore be designed to promote airflow through the areas where cooling is required.
For an exhaust-based arrangement, a suitable filtered air inlet is generally required to replace the air removed by the fan. The inlet and exhaust positions should be selected to reduce short-circuit airflow paths and encourage effective circulation through the enclosure.
A key distinguishing feature of the Finder 7F.21.8.120.4400.0 is its black housing and external grille. This makes the model particularly suitable for electrical enclosures where a black or dark-coloured finish is preferred.
Black electrical cabinets are commonly used in specialist machinery, equipment housings, production systems and custom-built industrial installations. Using a matching black filter fan can help maintain a consistent appearance across the enclosure without changing the fundamental ventilation function.
The .0 suffix is important when identifying this particular product variant. The Finder 7F.21.8.120.4400.0 is the black version of the Size 4 reverse flow filter fan, while the corresponding 7F.21.8.120.4400 is the standard-colour version.
When replacing an existing fan, the full part number should be checked carefully to ensure the correct voltage, airflow direction, airflow capacity, physical size and colour are selected.
Electrical enclosure temperature management plays an important role in the long-term reliability of industrial automation equipment. Excessive internal temperatures can reduce the service life of electronic components and may lead to unwanted equipment shutdowns or reduced performance.
The Finder 7F.21.8.120.4400.0 helps manage these conditions by providing active air extraction. Where the surrounding ambient air is sufficiently cool, forced ventilation can remove heat from the cabinet and help maintain an acceptable internal operating temperature.
However, a filter fan cannot cool an electrical cabinet below the temperature of the incoming ambient air. In environments where the ambient temperature is too high, or where the enclosure must remain sealed against aggressive contaminants, an enclosure air conditioner or another cooling system may be more appropriate.
Fan selection should account for the total heat generated by the installed electrical equipment, the maximum permissible cabinet temperature, the ambient conditions and the actual airflow resistance of the ventilation arrangement.
The Size 4 construction is intended for installation into a correctly prepared electrical enclosure opening. The mounting position should provide sufficient clearance for the fan assembly, internal equipment and the required airflow path.
Before cutting the cabinet panel, installers should refer to the current Finder dimensional drawing for the exact mounting aperture, fixing method and installation tolerances. This is particularly important when replacing an existing fan or fitting the assembly into a pre-manufactured enclosure.
The 120 V AC supply must be connected using appropriately rated wiring and protection. Electrical installation should be completed by a suitably qualified person in accordance with the manufacturer's instructions and applicable electrical regulations.
The filter element should be inspected periodically. Dust accumulation can restrict airflow and reduce cooling performance, so filter maintenance intervals should reflect the environmental conditions surrounding the electrical cabinet.
The UL Type 12 protection classification is intended for suitable indoor industrial enclosure applications. The overall enclosure protection depends on correct installation, the associated ventilation components and the condition of the filter and grille assembly.
Tick the specs you need, then view products that match.
| Cut-Out Size (mm) | 223 × 223 mm | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 7F Series | |
| Model | 7F.21.8.120.4400.0 | |
| Product type | Industrial enclosure filter fan | |
| Fan configuration | Reverse flow / exhaust | |
| Airflow direction | From inside the enclosure to the outside | |
| Housing colour | Black | |
| Nominal supply voltage | 120 V AC | |
| Supply type | Alternating current | |
| Rated power consumption | 120 W | |
| Nominal free-air airflow | 400 m³/h | |
| Approximate free-air airflow | 262 CFM | |
| Fan size | Size 4 | |
| Nominal size class | 10-inch | |
| Protection classification | UL Type 12 | |
| Application environment | Indoor industrial electrical enclosures | |
| Mounting type | Enclosure panel mounting | |
| Filter arrangement | Integrated filter fan assembly with serviceable filter media | |
| Ventilation function | Forced-air exhaust | |
| Typical installation | Electrical cabinet sidewall or suitable enclosure panel | |
| Primary application | Electrical enclosure thermal management | |
| Standard-colour equivalent | Finder 7F.21.8.120.4400 | |
| Colour suffix | .0 – black version | |
| Actual installed airflow | Dependent on cabinet airflow resistance, inlet filtration and installation conditions | |
| Installation requirements | Follow Finder's applicable dimensional drawings, electrical connection instructions and ventilation guidance |
The Finder 7F.21.8.120.4400.0 is a reverse flow filter fan used to extract warm air from industrial electrical cabinets, switchboards and automation enclosures. It helps manage heat generated by electrical and electronic equipment.
It is a reverse flow exhaust fan. The fan is designed to move air from inside the electrical cabinet to the outside, rather than drawing ambient air into the enclosure.
The fan is designed for a nominal 120 V AC supply. The electrical supply and installation must comply with the manufacturer's operating requirements.
The fan has a nominal free-air airflow of 400 m³/h, equivalent to approximately 262 CFM. Actual installed airflow will depend on the ventilation system's resistance and enclosure arrangement.
The Finder 7F.21.8.120.4400.0 has a specified 120 W power rating. The supply circuit should be selected according to the manufacturer's electrical requirements.
This model has a black housing and external grille. The final .0 suffix identifies the black variant.
The fan uses the Finder Size 4 mounting format, also described as a 10-inch class filter fan. The manufacturer's dimensional drawing should be checked before preparing the enclosure opening.
The fan is specified with a UL Type 12 enclosure protection classification for suitable indoor industrial applications. The protection achieved by the complete enclosure depends on correct installation.
Yes. The fan incorporates a serviceable filter arrangement. The correct replacement filter should be selected according to Finder's Size 4 accessory and maintenance documentation.
It is designed for industrial enclosure ventilation and can be incorporated into a continuously operating cooling arrangement, provided the installation remains within the manufacturer's electrical, environmental and operating limits.
Both are 120 V AC Size 4 reverse flow filter fans with a nominal 400 m³/h airflow class. The principal difference is the finish: the 7F.21.8.120.4400.0 is black, while the 7F.21.8.120.4400 is the standard-colour version.
Both are black Size 4 filter fans designed for 120 V AC supplies. The main difference is airflow direction: the 7F.21.8.120.4400.0 is the reverse flow exhaust version, while the 7F.20.8.120.4400.0 is the standard intake version.
Finder 7F Series filter fans provide practical forced-air ventilation solutions for industrial electrical cabinets, automation panels and machinery enclosures. With a 120 V AC supply, 400 m³/h nominal free-air capacity, reverse flow exhaust operation, Size 4 construction, UL Type 12 protection and a distinctive black housing, the Finder 7F.21.8.120.4400.0 is a reliable choice for electrical engineers, industrial panel builders, machine manufacturers and maintenance professionals requiring high-volume enclosure ventilation.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.