Finder 7F.21.8.120.2055 is a Size 2 reverse-flow exhaust filter fan for electrical enclosures, featuring a 120 V AC 50/60 Hz supply, 55 m³/h free-air airflow, 30/25 W rated power, IP54 protection, 155 x 155 mm front dimensions, RAL 7035 housing and replaceable filter mat.
£46.30
The Finder 7F.21.8.120.2055 is a compact 120 V AC reverse-flow exhaust filter fan designed to remove warm air from industrial electrical enclosures, control cabinets and switchboards. Part of the Finder 7F Series, this Size 2 ventilation unit combines an electrically powered fan with a replaceable filter assembly to support effective thermal management in industrial and commercial electrical installations.
Featuring a nominal 120 V AC, 50/60 Hz supply and a 55 m³/h free-air airflow rating, the Finder 7F.21.8.120.2055 provides forced exhaust ventilation for electrical cabinets containing heat-generating components such as power supplies, relays, drives and electronic control equipment.
Unlike a conventional intake filter fan, this reverse-flow version is designed to extract air from the enclosure. It is particularly useful where the ventilation system requires an active exhaust fan rather than relying solely on a passive outlet.
The unit features a 155 × 155 mm front housing, a light grey RAL 7035 finish, a replaceable filter mat and an IP54 protection rating when correctly installed. Its compact, panel-mounted construction makes it a practical solution for machine builders, electrical engineers, control panel manufacturers and maintenance professionals.
The Finder 7F.21.8.120.2055 uses an electrically powered fan to extract air from an electrical enclosure.
During normal operation, heat-producing electrical components raise the temperature of the air inside the cabinet. The reverse-flow fan draws this warmer air towards the enclosure outlet and expels it through the fan assembly.
As air is removed, replacement air enters through a suitable inlet or ventilation opening. This establishes an airflow path that can help reduce the internal cabinet temperature.
The fan is rated for a free-air volume flow of 55 m³/h. This is the airflow measured under free-flow conditions and should not be interpreted as the guaranteed airflow through every installed enclosure.
The actual airflow depends on factors including filter resistance, inlet dimensions, enclosure layout and pressure losses through the complete ventilation system.
For effective cooling, the fan must be correctly sized for the cabinet's internal heat load and the surrounding ambient temperature.
The primary difference between the Finder 7F.21 and standard Finder 7F.20 filter fan arrangements is the direction of airflow.
A standard intake filter fan is typically used to draw cooler external air into an electrical enclosure. The air then circulates through the cabinet before leaving through an exhaust opening.
The Finder 7F.21.8.120.2055 instead provides active exhaust ventilation, drawing air out of the cabinet.
This arrangement can be useful where enclosure layout, equipment positioning or the required airflow path makes active air extraction preferable.
The choice between intake and exhaust ventilation should consider the complete system, including dust exposure, filtration, cabinet pressure and the location of heat-producing equipment.
The Finder 7F.21.8.120.2055 has an IP54 ingress protection rating when installed in accordance with the manufacturer's instructions.
IP54 indicates protection against harmful dust ingress and splashing water under the relevant test conditions.
The fan's housing and filter assembly help support enclosure ventilation while limiting the entry of airborne contaminants through the fan opening.
Correct installation is essential. The final ingress protection of the complete electrical cabinet depends on the enclosure construction, seals, other openings and all fitted ventilation components.
The product is also listed with a NEMA Type 12 classification, making it suitable for appropriately designed indoor industrial enclosures.
It should not be assumed to provide unrestricted outdoor weather protection or resistance to high-pressure water jets.
The Finder 7F.21.8.120.2055 includes a filter assembly designed for routine inspection and maintenance.
Its replaceable filter mat helps manage airborne contamination around the ventilation opening. Over time, accumulated dust can increase airflow resistance and reduce cooling performance.
The compatible Finder 07F.25 replacement filter mat allows the filter material to be renewed without replacing the complete fan assembly.
The inspection and replacement interval should reflect the surrounding environment. Electrical cabinets installed in dusty production areas may require more frequent maintenance than those located in clean electrical rooms.
Regular filter maintenance helps preserve ventilation performance and reduces the risk of excessive enclosure temperatures caused by restricted airflow.
Electrical control cabinets often contain components that generate heat during operation, including contactors, relays, power supplies, transformers, variable speed drives and electronic control modules.
If this heat is not adequately managed, the internal cabinet temperature can rise above the recommended operating limits of the installed equipment.
The Finder 7F.21.8.120.2055 helps address this by providing forced exhaust airflow, removing warm air and supporting circulation through the enclosure.
The required ventilation capacity depends on the total internal heat dissipation, ambient temperature, target cabinet temperature and the pressure losses of the ventilation system.
For best results, the fan should be selected as part of a complete thermal management design rather than solely on its nominal free-air airflow rating.
The Finder 7F.21.8.120.2055 is designed for mounting into a suitable electrical enclosure wall or panel using its snap-in mounting arrangement.
The unit has a 155 × 155 mm front housing, allowing it to be incorporated into compatible Size 2 enclosure ventilation arrangements.
The fan requires a nominal 120 V AC electrical supply at 50/60 Hz.
Important: This model is not a 230 V AC fan. It must not be connected directly to a standard UK 230 V mains supply unless a correctly rated voltage conversion arrangement is provided.
The exact panel cut-out, mounting clearances, terminal connections and protective arrangements should be confirmed against the manufacturer's installation drawing before fitting.
The fan can be incorporated into a temperature-controlled ventilation system using a suitable thermostat or control device, allowing ventilation to operate when the cabinet reaches a predetermined temperature.
Tick the specs you need, then view products that match.
| Cut-Out Size (mm) | 125 × 125 mm | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 7F Series | |
| Type | 7F.21 | |
| Model | 7F.21.8.120.2055 | |
| Product category | Electrical enclosure ventilation | |
| Product type | Reverse-flow exhaust filter fan | |
| Ventilation direction | Exhaust / air extraction | |
| Fan size | Size 2 | |
| Nominal operating voltage | 120 V AC | |
| Voltage type | AC | |
| Operating frequency | 50/60 Hz | |
| Free-air volume flow | 55 m³/h | |
| Free-air airflow | Approximately 32.4 CFM | |
| Rated power at 50 Hz | 30 W | |
| Rated power at 60 Hz | 25 W | |
| Front housing width | 155 mm | |
| Front housing height | 155 mm | |
| Installation depth | Approximately 66.2 mm | |
| Housing colour | Light grey | |
| RAL colour | RAL 7035 | |
| Ingress protection | IP54 | |
| NEMA classification | Type 12 | |
| Noise emission | Approximately 42 dB(A) | |
| Fan motor | Integrated | |
| Filter included | Yes | |
| Filter mat | Replaceable | |
| Compatible replacement filter mat | Finder 07F.25 | |
| Mounting method | Snap-in panel mounting | |
| Suitable installation | Electrical enclosure wall or panel | |
| Matching Size 2 exhaust filter | Finder 7F.02.0.000.2000 | |
| Compliance | RoHS compliant |
The Finder 7F.21.8.120.2055 is a reverse-flow exhaust filter fan used to remove warm air from industrial electrical cabinets, control panels and switchboards.
The fan operates from a nominal 120 V AC supply at 50/60 Hz. It must not be connected directly to an incompatible supply voltage.
The fan has a 55 m³/h free-air airflow rating, equivalent to approximately 32.4 CFM. Actual installed airflow depends on the enclosure and ventilation system resistance.
It is a reverse-flow exhaust fan, designed to actively extract air from an electrical enclosure rather than draw external air into the cabinet.
The unit is a Size 2 filter fan with a front housing measuring 155 × 155 mm and an approximate installation depth of 66.2 mm.
The manufacturer's 7F Series data lists a rated power of 30 W at 50 Hz and 25 W at 60 Hz for this 120 V AC Size 2 configuration.
The fan has an IP54 protection rating when correctly installed, helping protect against harmful dust ingress and splashing water.
Yes. Unlike a passive exhaust filter, this product includes an electrically powered fan motor that actively extracts air from the enclosure.
Yes. The filter mat is replaceable. The corresponding Finder 07F.25 Size 2 replacement filter mat is used for maintenance.
No. This model is rated for 120 V AC, while standard UK mains supplies are nominally 230 V AC. A suitable 230 V version or correctly designed voltage conversion arrangement is required.
The fan has a listed noise emission of approximately 42 dB(A). Actual perceived noise depends on the installation and operating environment.
Yes. The fan can be switched by a suitable thermostat or control device rated for its 120 V AC electrical supply and motor load, allowing ventilation to operate according to cabinet temperature.
Both are Size 2 reverse-flow exhaust filter fans with a nominal 55 m³/h airflow rating. The 7F.21.8.120.2055 operates from 120 V AC, while the 7F.21.8.230.2055 is designed for a 230 V AC supply.
The replacement interval depends on airborne dust levels, operating hours and enclosure conditions. The filter should be inspected regularly and replaced when contamination begins to restrict airflow.
The Finder 7F.21.8.120.2055 combines 120 V AC operation, 55 m³/h free-air airflow, reverse-flow exhaust ventilation and IP54 protection in a compact Size 2 filter fan assembly. Its replaceable filter mat, low-noise design and practical panel mounting make it a reliable choice for industrial control cabinet ventilation and electrical enclosure cooling.