Partex HS21016BROWN brown 2:1 heat shrink tubing with a 101.6 mm supplied internal diameter, 50.8 mm nominal recovered internal diameter and 15 m pack quantity, designed for electrical insulation, large-diameter cable protection and suitable colour-coded line conductor identification.
£283.01
The Partex HS21016BROWN is a large-diameter brown heat shrink tubing designed for electrical insulation, cable protection, conductor identification and professional cable management. Featuring a 2:1 shrink ratio, this tubing reduces from a nominal supplied internal diameter of 101.6 mm to 50.8 mm when fully recovered, providing a close-fitting protective sleeve around appropriately sized cables, cable bundles and electrical components.
Manufactured by Partex, a specialist in cable identification and electrical installation products, this brown heat shrink tubing offers a practical solution for protecting larger cable assemblies while supporting clear and consistent conductor identification. Its distinctive brown colour is particularly useful in colour-coded electrical installations, helping electricians, control panel builders and maintenance engineers distinguish designated line conductors and cable groups.
Supplied in a convenient 15 m pack, the HS21016BROWN is suitable for electrical contractors, industrial manufacturers, automation engineers and maintenance professionals requiring large-diameter protective sleeving. With its 101.6 mm supplied internal diameter and 50.8 mm nominal recovered internal diameter, it is particularly useful for larger cables, grouped conductors, electrical terminations and industrial cable protection applications.
Heat shrink tubing is widely used in electrical and industrial installations to provide protective sleeving around conductors, cable connections and electrical components. When suitable heat is applied, the tubing contracts around the underlying component, creating a close-fitting covering that can help protect against abrasion and provide additional electrical insulation where the product is appropriately specified.
The Partex HS21016BROWN combines a practical 2:1 shrink ratio with a generous 101.6 mm supplied internal diameter. This larger opening makes it particularly useful when protective sleeving must pass over wider cable assemblies, grouped conductors or components that cannot be accommodated by smaller-diameter tubing. Once heated, the tubing contracts towards its nominal recovered internal diameter of 50.8 mm.
In UK and European harmonised electrical installations, brown is the recognised identification colour for line conductors in single-phase wiring and is commonly associated with the L1 phase in three-phase systems. Brown heat shrink sleeving can therefore assist with line conductor identification at suitable cable terminations and within electrical equipment. However, its use must comply with applicable wiring regulations, and brown sleeving should not be applied in a way that could incorrectly identify a conductor's function. Where a cable bundle contains multiple conductor types, the brown outer sleeve must not create confusion about the conductors within it.
For effective installation, select tubing with a supplied internal diameter large enough to pass over the intended cable, connector or component and a recovered diameter suitable for the required fit. Cut the tubing to length and apply controlled, even heat using an appropriate heat gun, following the manufacturer's installation recommendations. Avoid excessive heating of the tubing or underlying cable insulation. Where waterproofing, adhesive bonding or a specified environmental seal is required, select a product with the relevant verified properties rather than assuming standard heat shrink tubing provides a sealed connection.
Tick the specs you need, then view products that match.
| Supply Format | 15 m | |
|---|---|---|
| Device Type | Heat-shrink tubing | |
| Material | Polyolefin | |
| Cable Diameter (mm) | 50.8–101.6 mm | |
| Internal Diameter Before Shrinking (mm) | 101.6 mm | |
| Shrink Ratio | 2:1 | |
| Colour | Brown | |
| Adhesive Lined | No | |
| Manufacturer | Partex | |
| Model / Part number | HS21016BROWN | |
| Product type | Heat shrink tubing | |
| Shrink ratio | 2:1 | |
| Supplied internal diameter | 101.6 mm | |
| Nominal recovered internal diameter | 50.8 mm | |
| Colour | Brown | |
| Pack quantity | 15 m | |
| Installation method | Heat shrinking | |
| Primary function | Electrical insulation, cable protection and conductor identification | |
| Typical applications | Larger cables, cable bundles, electrical equipment and industrial cable assemblies | |
| HS Code | 39269097 |
The Partex HS21016BROWN is used for electrical insulation, cable protection and conductor identification. Its large supplied diameter makes it particularly suitable for appropriately sized larger cables, cable bundles, electrical connections and industrial cable assemblies.
The tubing has a 2:1 shrink ratio, with a nominal supplied internal diameter of 101.6 mm and a nominal recovered internal diameter of 50.8 mm when fully shrunk under suitable heating conditions.
The HS21016BROWN is supplied in a 15 m pack, providing a practical quantity of large-diameter heat shrink sleeving for electrical contractors, industrial manufacturers and maintenance professionals.
Yes. Brown heat shrink tubing can be used for line conductor identification where appropriate. Brown is the recognised line conductor colour in UK and European harmonised single-phase electrical installations and is commonly associated with the L1 phase in three-phase wiring systems. The selected identification method must comply with applicable electrical regulations, and brown sleeving must not incorrectly identify a neutral conductor, protective earth conductor or mixed cable bundle as a line conductor.
Cut the tubing to the required length, position it over a suitably sized cable, cable bundle or electrical component and apply controlled, even heat using an appropriate heat gun. Heat the tubing evenly in accordance with the manufacturer's recommendations so that it contracts around the component to provide a close-fitting brown protective sleeve.
Partex cable identification and electrical installation products are used by electrical engineers, control panel builders and industrial maintenance professionals. The HS21016BROWN large-diameter brown heat shrink tubing provides a practical solution for cable protection, electrical insulation and suitable line conductor identification in professional industrial and commercial electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.