Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Partex ECHS224GREY is grey 2:1 heat shrink tubing with a nominal diameter of 2.4 mm before shrinking and 1.2 mm after shrinking, suitable for compatible electrical wire sleeving, cable identification and general conductor protection applications, supplied in a 150 m pack.
£33.74
The Partex ECHS224GREY is a professional 2:1 heat shrink tubing product designed for electrical wire sleeving, cable identification, insulation and general conductor protection applications. Supplied in grey, with a nominal diameter of 2.4 mm before shrinking and 1.2 mm after shrinking, this heat shrink sleeving offers a practical solution for smaller electrical wires, cable assemblies and control panel wiring.
Featuring a 2:1 shrink ratio, the Partex ECHS224GREY is designed to reduce its diameter when suitable heat is applied, allowing the tubing to conform around compatible wires and electrical components. Its compact size makes it useful for applications requiring a neat, close-fitting sleeve without excessive bulk.
Supplied in a generous 150 m pack, this grey heat shrink tubing is particularly suitable for electrical contractors, control panel builders, industrial maintenance departments and OEM equipment manufacturers who regularly use heat shrink sleeving. The substantial supplied length provides a convenient stock quantity for repeated cutting and installation across multiple electrical wiring tasks.
The grey colour is useful for maintaining a consistent appearance in electrical assemblies and for colour-coded cable identification where permitted by the applicable wiring standards. Combining a 2.4/1.2 mm size, 2:1 shrink ratio and 150 m supply length, the ECHS224GREY is a practical addition to professional electrical installation and cable management supplies.
The shrink ratio is an important consideration when selecting heat shrink tubing. A 2:1 ratio means the tubing is designed to recover to approximately half its original nominal diameter when the appropriate heat is applied under suitable conditions.
For the Partex ECHS224GREY, the nominal diameter before shrinking is 2.4 mm, while the nominal fully recovered diameter is 1.2 mm. This combination makes the tubing suitable for compatible smaller wires and components where the sleeve must initially pass over the item and subsequently shrink to achieve the intended fit.
Correct sizing requires consideration of both dimensions. The tubing must be large enough to slide over the cable or component before heating, while the recovered diameter must be sufficiently small to provide the required contact around the underlying surface.
Installers should also consider the difference between a conductor's cross-sectional area and its overall outside diameter. For example, a wire described as 0.75 mm² refers to the conductor's cross-sectional area, not the external diameter of its insulation. The actual outside diameter should therefore be checked before selecting heat shrink tubing.
For applications involving cable joints, connectors or irregularly shaped components, the largest dimension that the tubing must pass over should be measured. Manufacturer tolerances and any specified longitudinal shrinkage should also be considered when determining the required tubing length and diameter.
Heat shrink tubing is commonly used in professional electrical installations to cover selected sections of wires, cable assemblies and compatible electrical components. The Partex ECHS224GREY provides a practical method of applying a close-fitting sleeve around appropriately sized conductors.
When heated correctly, the tubing contracts around the underlying component, creating a neat finish that can help protect the covered area from incidental contact and handling. This is particularly useful in electrical control panels, equipment wiring and cable assemblies where a tidy and organised installation is important.
Heat shrink sleeving can also be useful when finishing compatible wire terminations or covering selected areas of a wiring harness. However, it should not be assumed that any heat shrink tubing can replace the original insulation of a damaged cable or provide a complete environmental seal.
Where the application requires a particular voltage rating, dielectric strength, operating temperature, flame performance, chemical resistance or moisture protection, the relevant Partex technical specifications should be verified before installation. The supplied product information identifies the shrink ratio, dimensions, colour and quantity but does not establish these additional performance ratings.
The grey finish of the Partex ECHS224GREY provides a neutral appearance that can complement electrical cabinets, control panels and industrial equipment. Grey sleeving can be useful where wiring systems require a consistent visual finish or where colour coding forms part of an established cable identification process.
In electrical manufacturing and panel assembly, colour-coded tubing can help distinguish wire groups, equipment sections or cable functions. A consistent approach to sleeving can make assemblies easier to inspect and maintain, particularly where the wiring layout is supported by clear documentation.
Where grey is used for conductor identification, installers must follow the applicable wiring regulations and site-specific identification scheme. In particular, grey is a recognised line conductor colour in certain harmonised wiring systems, so its use should not create confusion about conductor function.
The ECHS224GREY is therefore best selected with consideration for both its physical dimensions and the identification requirements of the installation. Its 2.4/1.2 mm dimensions make it particularly useful for smaller wire sleeving applications where a compact and professional finish is required.
The 150 m supply length makes the Partex ECHS224GREY a convenient choice for organisations that regularly use heat shrink tubing. Electrical contractors, industrial maintenance teams and cable assembly manufacturers can cut the tubing into individual sleeves as required, reducing the need to purchase separate short lengths for every task.
For control panel builders, keeping a consistent heat shrink size available can help standardise cable finishing and identification across multiple electrical assemblies. The grey finish is particularly suitable where a neutral appearance is preferred or where the relevant wiring scheme specifies grey sleeving.
For OEM electrical equipment manufacturers, the bulk quantity supports repeated assembly operations involving compatible wire sizes. The tubing can be incorporated into established production processes, provided the application requirements and installation conditions match the manufacturer's specifications.
Maintenance departments can also benefit from keeping heat shrink sleeving available for planned servicing, equipment refurbishment and compatible electrical repairs. The stated 150 m quantity refers to the total supplied tubing length; the packaging and dispensing arrangement should be confirmed where these details are important.
Correct installation helps ensure that heat shrink tubing contracts evenly and fits the intended cable or component. The following general procedure provides practical guidance, subject to the manufacturer's specific instructions.
Electrical circuits should be made safe before installation or maintenance work. Avoid uncontrolled flames and excessive heat, particularly near sensitive components, cable insulation or combustible materials.
Tick the specs you need, then view products that match.
| Supply Format | 150 m | |
|---|---|---|
| Device Type | Heat-shrink tubing | |
| Material | Polyolefin | |
| Cable Diameter (mm) | 1.2–2.4 mm | |
| Internal Diameter Before Shrinking (mm) | 2.4 mm | |
| Shrink Ratio | 2:1 | |
| Colour | Grey | |
| Adhesive Lined | No | |
| Manufacturer | Partex | |
| Model | ECHS224GREY | |
| Product type | Heat shrink tubing | |
| Shrink ratio | 2:1 | |
| Nominal diameter before shrinking | 2.4 mm | |
| Nominal diameter after shrinking | 1.2 mm | |
| Nominal tubing size | 2.4/1.2 mm | |
| Colour | Grey | |
| Supplied length | 150 m | |
| Primary function | Electrical wire sleeving, insulation and cable identification | |
| Installation method | Heat shrinking using a suitable controlled heat source | |
| Typical applications | Electrical wiring, control panels, cable assemblies and equipment maintenance | |
| Product code | ECHS224GREY | |
| HS Code | 39269097 |
The Partex ECHS224GREY is grey 2:1 heat shrink tubing used for compatible electrical wire sleeving, insulation, cable identification and general conductor protection applications. It has a nominal diameter of 2.4 mm before shrinking and 1.2 mm after shrinking.
A 2:1 shrink ratio means the tubing is designed to reduce its nominal diameter to approximately half its original size when correctly heated. For the ECHS224GREY, the nominal diameter changes from 2.4 mm to 1.2 mm after full recovery.
The ECHS224GREY has a nominal supplied diameter of 2.4 mm and a nominal recovered diameter of 1.2 mm. The cable or component must fit inside the tubing before heating, and its outside diameter must be suitable for the intended recovered fit. Always check the actual outside diameter rather than relying solely on conductor cross-sectional area.
The Partex ECHS224GREY is supplied in a 150 m pack. This quantity is suitable for electrical contractors, panel builders, maintenance teams and manufacturers who require tubing for repeated wiring and cable assembly tasks.
Yes, grey heat shrink tubing can be used for cable identification where the application and wiring standards permit it. Grey is also a recognised line conductor colour in certain harmonised wiring systems, so the identification scheme must remain clear and compliant with the relevant regulations.
A waterproof or adhesive-lined construction has not been specified for the ECHS224GREY. Standard heat shrink tubing should not automatically be treated as a waterproof seal. Where moisture protection or environmental sealing is required, confirm the manufacturer's product specifications and select an appropriately rated tubing system.
The exact shrink temperature has not been specified in the available product details. Use a suitable controlled heat source and follow the manufacturer's recommended installation temperature. Avoid excessive heating, which could damage the tubing or the underlying cable insulation.
The Partex ECHS224GREY provides a practical solution for electrical wire sleeving, cable identification and general conductor protection. Combining a 2:1 shrink ratio, 2.4/1.2 mm nominal diameters, a professional grey finish and a generous 150 m supply length, it is a useful choice for electrical contractors, industrial maintenance teams, control panel builders and OEM cable assembly operations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.