Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Partex PXA2-75L A1/A2 brass unarmoured cable gland with M75 metric thread and 60.5–67.0 mm cable outside diameter capacity, designed for secure cable entry, mechanical retention and compression sealing in industrial electrical enclosures and power distribution installations.
£21.69
The Partex PXA2-75L is a heavy-duty A1/A2 unarmoured cable gland designed to provide secure cable entry, mechanical retention and environmental sealing for large-diameter unarmoured electrical cables. Featuring an M75 metric thread and a specified cable outside diameter range of 60.5–67.0 mm, this cable gland is suitable for industrial electrical enclosures, power distribution equipment and heavy-duty electrical installations.
Part of the Partex A1/A2 unarmoured cable gland range, the PXA2-75L provides a practical solution for terminating large unarmoured cables at enclosure entry points. Its compression sealing arrangement is designed to grip the cable outer sheath, helping maintain cable positioning and supporting environmental protection when the gland is correctly selected and installed.
With its M75 threaded connection and capacity to accommodate cables measuring 60.5–67.0 mm in outside diameter, the PXA2-75L is particularly suitable for large industrial power cables and multicore electrical cables. Its robust construction and straightforward installation make it a practical choice for electrical contractors, panel builders and industrial maintenance engineers working with substantial cable installations.
Cable glands are essential components in industrial electrical installations, providing a secure interface between cables and the equipment they enter. The Partex PXA2-75L is designed for large unarmoured cables, using a compression sealing arrangement to help grip the cable outer sheath and maintain a secure connection at the enclosure entry point. Correct gland selection supports organised cable routing, reduces mechanical strain and helps protect electrical equipment from environmental exposure.
The Partex A1/A2 range is intended for electrical installers, panel manufacturers and industrial maintenance engineers who require dependable cable entry solutions. When selecting the PXA2-75L, the cable outside diameter must fall within the specified 60.5–67.0 mm range, and the enclosure must provide a compatible M75 threaded entry. Appropriate sealing accessories, tightening procedures and installation practices should be followed to achieve the required mechanical and environmental performance.
Tick the specs you need, then view products that match.
| Application | Armoured cable | |
|---|---|---|
| Device Type | Armoured cable gland | |
| Thread Size | M75 | |
| Cable Diameter (mm) | 60.5–67 mm | |
| Manufacturer | Partex | |
| Series | A1/A2 Unarmoured Cable Glands | |
| Model | PXA2-75L | |
| Product type | Unarmoured cable gland | |
| Gland classification | A1/A2 | |
| Gland material | Brass | |
| Thread type | Metric | |
| Thread size | M75 | |
| Nominal metric thread diameter | 75 mm | |
| Suitable cable outside diameter | 60.5–67.0 mm | |
| Minimum cable outside diameter | 60.5 mm | |
| Maximum cable outside diameter | 67.0 mm | |
| Cable type | Unarmoured electrical cable | |
| Sealing method | Compression sealing around the cable outer sheath | |
| Mounting type | Threaded enclosure or gland plate entry | |
| Installation environment | Industrial electrical enclosures and equipment | |
| Application | Large-diameter unarmoured cable entry and mechanical retention | |
| HS Code | 85369010 |
The Partex PXA2-75L is an A1/A2 unarmoured cable gland designed to secure and seal large electrical cables where they enter industrial enclosures, power distribution equipment and electrical installations.
The PXA2-75L is designed for unarmoured cables with an outside diameter between 60.5 mm and 67.0 mm. The actual cable outside diameter should be checked before selecting the gland.
The cable gland features an M75 metric thread, suitable for compatible threaded electrical enclosure entries and gland plate installations.
No. The Partex PXA2-75L is designed for unarmoured electrical cables. Armoured cables require an appropriately specified gland capable of providing the necessary armour retention and electrical continuity.
The PXA2-75L is commonly used in industrial power distribution equipment, electrical switchgear, machinery and large electrical enclosures where unarmoured cables measuring 60.5–67.0 mm in outside diameter require secure entry and mechanical retention.
Partex cable installation products support electrical contractors, industrial engineers and panel manufacturers in achieving organised and dependable electrical installations. The PXA2-75L A1/A2 unarmoured cable gland provides a robust solution for securing large-diameter electrical cables at industrial enclosure entry points, supporting professional cable management and reliable equipment connections.
We use cookies