PXA2-63S Partex A1/A2 Unarmoured Cable Glands, M63, cable Ø 42.5 to 50.0mm

PXA2-63S Partex A1/A2 Unarmoured Cable Glands, M63, cable Ø 42.5 to 50.0mm

Partex PXA2-63S A1/A2 brass unarmoured cable gland kit with M63 metric thread, 15 mm thread length and 42.5–50.0 mm cable diameter capacity, supplied with a brass locknut, PVC shroud and earth tag with screw for indoor and outdoor electrical installations.

SKU: PXA2-63SMPN: PXA2-63S
Price
List Price £20.17 ex VAT
Your Price (ex VAT) Save 25%
£15.13 25% OFF
You save £5.04 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £15.13
Trade pricing is personalised to your account

Manufacturer Lead Time

£15.13

Why Choose the Partex PXA2-63S A1/A2 Unarmoured Cable Gland?

The Partex PXA2-63S is an industrial A1/A2 unarmoured cable gland designed to provide secure cable entry, mechanical retention and environmental sealing for unarmoured electrical cables. Featuring an M63 metric thread and a specified cable outside diameter range of 42.5–50.0 mm, this cable gland is suitable for electrical enclosures, industrial control panels and power distribution installations.

Part of the Partex A1/A2 cable gland range, the PXA2-63S is intended for installations where an unarmoured cable must pass securely through an enclosure wall or cable entry plate. The gland's compression sealing arrangement helps grip the cable outer sheath and supports a reliable installation when correctly selected and assembled.

With its M63 threaded connection and capacity to accommodate larger unarmoured cables, the PXA2-63S is particularly useful in industrial electrical systems, machinery and distribution equipment. Its cable diameter range makes it suitable for installations involving substantial power or multicore control cables, provided the cable construction and gland compatibility requirements are satisfied.

Key Advantages

  • Industrial A1/A2 cable gland designed for unarmoured electrical cables.
  • M63 metric thread for compatible electrical enclosure entries.
  • 42.5–50.0 mm cable outside diameter range for larger cable installations.
  • Compression sealing arrangement helps secure the cable outer sheath.
  • Supports professional cable entry into electrical cabinets and industrial enclosures.
  • Helps reduce unwanted cable movement at the enclosure entry point.
  • Suitable for industrial power distribution, machinery and electrical installation applications.
  • Practical solution for cable management and enclosure cable termination.

Key Features

  • Partex A1/A2 unarmoured cable gland range.
  • PXA2-63S model designation.
  • M63 metric threaded entry.
  • 42.5 mm minimum cable outside diameter.
  • 50.0 mm maximum cable outside diameter.
  • Designed for unarmoured electrical cables.
  • Compression-type cable sealing and retention arrangement.
  • Suitable for cable entry through compatible enclosure walls and gland plates.
  • Designed for professional electrical installation and industrial cable management.
  • Suitable for appropriately sized power and multicore cables.

Reliable Cable Entry for Industrial Electrical Enclosures

Cable glands provide an important connection between electrical cables and the equipment they enter. The Partex PXA2-63S is designed to accommodate unarmoured cables within its specified diameter range, helping provide mechanical retention and sealing at the enclosure entry point. Correct gland selection supports organised cable routing and helps protect electrical equipment from unwanted cable movement and external environmental exposure.

The Partex A1/A2 range is suitable for electrical installers, panel builders and industrial maintenance engineers working with unarmoured cables. For reliable installation, the cable outside diameter should be checked against the specified 42.5–50.0 mm range, and the gland should be fitted using the appropriate enclosure entry, sealing accessories and tightening procedure. Where a particular ingress protection rating or hazardous-area approval is required, the complete installation must meet the relevant equipment and application requirements.

Typical Applications

  • Industrial electrical control panels and switchgear assemblies.
  • Power distribution cabinets and electrical enclosures.
  • Industrial machinery and manufacturing equipment.
  • Unarmoured power cable entry into electrical equipment.
  • Multicore cable installations and industrial control systems.
  • Electrical junction boxes and cable termination enclosures.
  • OEM machine building and industrial electrical installations.
  • Electrical maintenance and replacement cable gland applications.

Technical Specifications

Tick the specs you need, then view products that match.

Application Armoured cable
Device Type Armoured cable gland
Thread Size M63
Cable Diameter (mm) 42.5–50 mm
Manufacturer Partex
Series A1/A2 Unarmoured Cable Glands
Model PXA2-63S
Product type Unarmoured cable gland
Gland classification A1/A2
Thread type Metric
Thread size M63
Nominal metric thread diameter 63 mm
Suitable cable outside diameter 42.5–50.0 mm
Minimum cable outside diameter 42.5 mm
Maximum cable outside diameter 50.0 mm
Cable type Unarmoured electrical cable
Sealing method Compression sealing around the cable outer sheath
Mounting type Threaded enclosure or gland plate entry
Application Industrial electrical cable entry and cable retention
HS Code 85369010

Frequently Asked Questions

What is the Partex PXA2-63S used for?

The Partex PXA2-63S is an A1/A2 unarmoured cable gland used to secure and seal electrical cables where they enter industrial enclosures, control panels and electrical distribution equipment.

What cable diameter does the PXA2-63S accommodate?

The PXA2-63S is designed for unarmoured cables with an outside diameter between 42.5 mm and 50.0 mm. The actual cable outside diameter should be checked before selecting the gland.

What thread size does the Partex PXA2-63S use?

The cable gland features an M63 metric thread, designed for compatible threaded enclosure entries or gland plate installations.

Is the PXA2-63S suitable for armoured cables?

No. The Partex PXA2-63S is designed for unarmoured cables. Armoured cables generally require a suitable armoured cable gland that provides the necessary armour retention and electrical continuity.

Where is the PXA2-63S typically installed?

The gland is typically installed in electrical control panels, industrial enclosures, distribution equipment and machinery where large unarmoured cables require secure entry and mechanical retention.

Trusted by Electrical Installers and Industrial Panel Builders

Partex cable installation and identification products support professional electricians, industrial engineers and panel manufacturers in achieving organised and dependable electrical installations. The PXA2-63S A1/A2 unarmoured cable gland provides a practical solution for securing larger electrical cables at industrial enclosure entry points.