Partex PXA2-50S M50 A1/A2 unarmoured cable gland designed for securing and sealing electrical cables with outside diameters of 31.5–37.0 mm at industrial electrical enclosure and control panel entry points.
£8.87
The Partex PXA2-50S is a robust M50 A1/A2 unarmoured cable gland designed to provide secure cable entry, mechanical retention and environmental sealing for unarmoured electrical cables. As part of the Partex PXA2 cable gland range, it is suitable for industrial electrical installations, control panels, junction boxes and electrical enclosures where dependable cable management and protection are essential.
Featuring a metric M50 threaded entry, the PXA2-50S is designed to accommodate unarmoured cables with an outside diameter of 31.5–37.0 mm. Its compression-type sealing arrangement grips the cable's outer sheath, helping maintain a secure entry point and reducing the risk of moisture and dust entering an enclosure when correctly installed with compatible sealing components.
The Partex PXA2-50S provides a practical cable termination solution for electrical contractors, panel builders and industrial maintenance engineers. Its A1/A2 gland configuration is intended for unarmoured cable applications, offering a straightforward method of securing cables as they pass through electrical equipment housings and cable entry plates.
Cable glands are essential components in electrical installations, providing a controlled entry point for cables passing into enclosures, junction boxes and electrical equipment. The Partex PXA2-50S M50 cable gland is designed for unarmoured cables, using a compression sealing arrangement to help secure the cable and protect the enclosure entry against environmental contamination.
The 31.5–37.0 mm cable diameter range makes this gland suitable for larger unarmoured power and control cables with compatible outer sheath dimensions. Selecting the correct gland size is important for achieving effective cable retention and sealing. Installers should check the cable's actual outside diameter rather than relying solely on its conductor cross-sectional area.
Unlike cable glands intended for armoured cables, an A1/A2 unarmoured gland does not provide armour clamping or an electrical earth connection through cable armour. Where an electrical installation requires a protective earth conductor, this must be provided through an appropriate earthing arrangement in accordance with the installation requirements.
For dependable installation, the PXA2-50S should be fitted to a compatible M50 threaded entry or gland plate using the appropriate mounting and sealing accessories. The final environmental protection of the assembly depends on the gland configuration, enclosure, installation method and any additional sealing components.
Tick the specs you need, then view products that match.
| Application | Armoured cable | |
|---|---|---|
| Thread Size | M50 | |
| Cable Diameter (mm) | 31.5–37 mm | |
| Device Type | Armoured cable gland | |
| Manufacturer | Partex | |
| Series | PXA2 Unarmoured Cable Glands | |
| Model | PXA2-50S | |
| Product type | A1/A2 unarmoured cable gland | |
| Gland type | Compression cable gland | |
| Entry thread size | M50 | |
| Thread type | Metric | |
| Nominal thread diameter | 50 mm | |
| Compatible cable outside diameter | 31.5–37.0 mm | |
| Cable type | Unarmoured electrical cable | |
| Sealing method | Compression seal around outer cable sheath | |
| Mounting type | Threaded enclosure or gland plate entry | |
| Application | Electrical cable entry, retention and sealing | |
| HS Code | 85369010 |
The Partex PXA2-50S is an M50 A1/A2 unarmoured cable gland used to secure and seal electrical cables where they enter control panels, junction boxes and other electrical enclosures. It provides mechanical cable retention and helps protect the cable entry point.
The PXA2-50S is designed for unarmoured electrical cables with an outside diameter of 31.5–37.0 mm. The cable's outer sheath diameter should be checked before installation to ensure compatibility with the gland.
The gland features an M50 metric threaded entry, designed for installation into a compatible M50 threaded enclosure opening or cable gland plate using suitable mounting accessories.
The PXA2-50S is designed for unarmoured cables and does not provide the armour clamping or earthing functionality required for terminating cable armour. Applications requiring armour termination should use an appropriately specified armoured cable gland.
The gland uses a compression-type sealing arrangement designed to help protect the cable entry against dust and moisture. The achieved protection depends on correct installation, compatible cable dimensions, the enclosure and any required sealing accessories.
Partex cable gland solutions support secure and organised electrical cable installations. The PXA2-50S M50 unarmoured cable gland provides a practical method of securing larger electrical cables at enclosure entry points, helping panel builders, electrical contractors and maintenance engineers achieve reliable cable management in industrial applications.