Partex PXA2-40L is an M40 A1/A2 unarmoured cable gland designed for secure cable entry and mechanical retention of compatible electrical cables with outside diameters from 25.0 mm to 32.0 mm.
£7.91
The Partex PXA2-40L is a professional M40 A1/A2 unarmoured cable gland designed for the secure entry and mechanical retention of compatible unarmoured electrical cables. Accommodating cable outside diameters from 25.0–32.0 mm, this cable gland provides a practical solution for electrical enclosures, industrial control panels, junction boxes and machinery installations.
Featuring an M40 metric entry thread, the PXA2-40L is intended for installation into suitably sized enclosure entries. Its A1/A2 gland configuration is designed for unarmoured cables, providing a cable entry and retention arrangement without the armour termination components associated with armoured cable glands.
The Partex PXA2-40L is particularly suitable for electrical installations involving larger-diameter unarmoured cables. Its specified 25.0–32.0 mm cable accommodation range allows installers, panel builders and maintenance engineers to select the appropriate gland for compatible cables, supporting organised cable routing and professional electrical installation practices.
Correctly selected cable glands play an important role in electrical installations by providing a suitable entry arrangement for cables passing into enclosures and equipment. The Partex PXA2-40L M40 cable gland is designed for unarmoured cables with outside diameters between 25.0 mm and 32.0 mm, making it suitable for applications requiring a larger cable accommodation range.
The M40 metric entry thread allows the gland to be installed in compatible enclosure openings, while its A1/A2 configuration provides a mechanical retention arrangement for the cable. This supports orderly cable routing into industrial control panels, electrical cabinets and machinery enclosures.
Unlike cable glands intended for steel wire armoured or other armoured cables, the PXA2-40L is specified for unarmoured cable applications. It should not be used as an armour termination or relied upon to provide electrical bonding of cable armour. Where armour termination is required, an appropriately specified armoured cable gland must be selected.
Before installation, the cable's actual outside diameter should be measured and checked against the 25.0–32.0 mm range. Installers should also verify the enclosure thread, gland material, environmental protection requirements and any necessary sealing or securing accessories. The completed installation must meet the applicable electrical and enclosure protection requirements.
Tick the specs you need, then view products that match.
| Application | Armoured cable | |
|---|---|---|
| Device Type | Armoured cable gland | |
| Thread Size | M40 | |
| Cable Diameter (mm) | 25–32 mm | |
| Manufacturer | Partex | |
| Model / SKU | PXA2-40L | |
| Product name | A1/A2 Unarmoured Cable Gland | |
| Product type | Electrical cable gland | |
| Gland classification | A1/A2 | |
| Cable type | Unarmoured | |
| Thread size | M40 | |
| Thread system | Metric | |
| Minimum cable outside diameter | 25.0 mm | |
| Maximum cable outside diameter | 32.0 mm | |
| Cable accommodation range | 25.0–32.0 mm | |
| Mounting arrangement | Threaded cable entry | |
| Primary function | Cable entry and mechanical retention | |
| Application | Electrical enclosures, control panels, junction boxes and industrial equipment | |
| Product category | Unarmoured Cable Glands | |
| HS Code | 85369010 |
The Partex PXA2-40L is an M40 A1/A2 unarmoured cable gland designed for electrical cables with outside diameters between 25.0 mm and 32.0 mm.
The PXA2-40L accommodates compatible unarmoured cables with outside diameters from 25.0 mm to 32.0 mm.
The PXA2-40L features an M40 metric entry thread for installation into compatible electrical enclosure entries.
No. The PXA2-40L is specified as an A1/A2 unarmoured cable gland. It does not provide the armour termination arrangement required for armoured cables.
A1/A2 identifies a cable gland configuration intended for compatible unarmoured cables. It provides a cable entry and retention arrangement rather than an armour clamping or bonding system.
Yes. The PXA2-40L can be used for compatible unarmoured cable entries in industrial control panels, provided the enclosure has a suitable M40 entry and the installation requirements are satisfied.
The PXA2-32S has an M32 thread and accommodates cable outside diameters of 17.5–22.5 mm. The PXA2-40L has an M40 thread and accommodates larger cables with outside diameters of 25.0–32.0 mm.
The exact ingress protection rating is not confirmed by the supplied product specification. The manufacturer's technical documentation should be consulted to verify the IP rating and any required installation accessories.
The supplied specification does not confirm whether a locknut, sealing washer or other accessories are included. The manufacturer's packaging information should be checked before installation.
Measure the cable's actual outside diameter and confirm that it falls within the gland's specified accommodation range. For the PXA2-40L, this is 25.0–32.0 mm. Also confirm the M40 enclosure entry, cable type and environmental requirements.
Partex cable management accessories support organised and professional electrical installations. The PXA2-40L A1/A2 unarmoured cable gland combines an M40 metric entry thread with a 25.0–32.0 mm cable diameter range, providing a practical cable entry solution for compatible industrial control panels, electrical enclosures and machinery installations.