Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Partex PXA2-25L is an M25 A1/A2 unarmoured cable gland designed for electrical enclosure cable entries and suitable for unarmoured cables with outside diameters from 16.0 to 19.5 mm.
£3.57
The Partex PXA2-25L is a professional M25 A1/A2 unarmoured cable gland designed for the entry and termination of suitable unarmoured electrical cables into control panels, junction boxes, distribution enclosures and industrial equipment. Featuring an M25 metric entry thread and a specified cable outside diameter range of 16.0–19.5 mm, this cable gland provides a practical solution for electrical installations requiring correctly sized cable entry components.
Part of the Partex A1/A2 unarmoured cable gland range, the PXA2-25L is intended for installations where cables do not require an armour termination. Its defined cable diameter range helps installers match the gland to the actual outside diameter of the cable, while the M25 threaded entry supports installation into compatible electrical enclosure openings. Correct gland selection is important for maintaining appropriate cable positioning and supporting an organised enclosure wiring arrangement.
The Partex PXA2-25L is suitable for electrical contractors, control panel manufacturers, machine builders and industrial maintenance professionals working with unarmoured power, control and auxiliary cables. The 16.0–19.5 mm cable diameter capacity makes this model relevant to larger unarmoured cable entries within the A1/A2 gland range, providing a dedicated option where smaller cable gland sizes are unsuitable.
Selecting the correct cable gland is essential for creating a suitable electrical enclosure entry. The Partex PXA2-25L is specified for unarmoured cables with an outside diameter between 16.0 mm and 19.5 mm, allowing installers to choose a gland that matches the cable dimensions. Its M25 metric entry thread provides a defined connection interface for compatible enclosure openings, supporting consistent cable entry arrangements across industrial electrical equipment.
When correctly installed, an appropriately selected cable gland helps support cable positioning and reduces unwanted movement at the enclosure entry. The PXA2-25L should be fitted according to the relevant Partex installation instructions, taking account of the cable outside diameter, enclosure entry dimensions, required securing accessories and installation environment. Where a particular ingress protection rating, material specification, temperature range or certification is required, these characteristics should be confirmed against the manufacturer's technical documentation before selection.
Tick the specs you need, then view products that match.
| Application | Armoured cable | |
|---|---|---|
| Device Type | Armoured cable gland | |
| Thread Size | M25 | |
| Cable Diameter (mm) | 16–19.5 mm | |
| Manufacturer | Partex | |
| Manufacturer part number | PXA2-25L | |
| Product range | A1/A2 Unarmoured Cable Glands | |
| Product type | Unarmoured cable gland | |
| Gland designation | A1/A2 | |
| Entry thread size | M25 | |
| Thread system | Metric | |
| Minimum cable outside diameter | 16.0 mm | |
| Maximum cable outside diameter | 19.5 mm | |
| Specified cable diameter range | 16.0–19.5 mm | |
| Cable type | Unarmoured electrical cable | |
| Primary function | Electrical cable entry and termination | |
| Product category | Electrical cable glands and cable entry accessories | |
| Typical installation | Electrical enclosures, control panels and junction boxes | |
| HS Code | 85369010 |
The Partex PXA2-25L is an M25 A1/A2 unarmoured cable gland designed for the entry and termination of suitable unarmoured electrical cables into compatible enclosures and equipment.
The PXA2-25L is specified for unarmoured cables with an outside diameter of 16.0–19.5 mm. The actual cable outside diameter should be measured or checked against the cable manufacturer's specification before selection.
The PXA2-25L features an M25 metric entry thread for installation into a compatible electrical enclosure entry.
No. The PXA2-25L is specified as an A1/A2 unarmoured cable gland. Cables requiring armour termination should use a suitably specified armoured cable gland.
Yes. The PXA2-25L is suitable for consideration in electrical control panel installations where the enclosure has a compatible M25 entry and the unarmoured cable outside diameter is within 16.0–19.5 mm.
A1/A2 identifies the unarmoured cable gland type. This distinguishes it from gland designs intended to terminate cable armour.
The supplied product specification does not state a particular IP rating. Any required ingress protection performance should be confirmed against the manufacturer's documentation and the complete installed enclosure arrangement.
The supplied product description does not confirm the inclusion of a locknut, sealing washer or other installation accessories. The supplied contents and any additional components required should be checked before installation.
Check the cable's actual outside diameter and the enclosure entry size. For the PXA2-25L, the cable should fall within the specified 16.0–19.5 mm diameter range, and the entry should be compatible with the M25 thread.
The PXA2-25L has an M25 thread and accepts cable outside diameters of 16.0–19.5 mm, whereas the PXA2-20S has an M20 thread and accepts cable outside diameters of 8.0–11.5 mm. Both are Partex A1/A2 unarmoured cable glands, but they are intended for different cable and enclosure entry sizes.
Partex A1/A2 unarmoured cable glands provide electrical contractors, control panel manufacturers and industrial maintenance professionals with practical cable entry solutions, supporting organised enclosure wiring, appropriate gland selection and consistent electrical installation practices.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.