Wago 750-479 2-Channel Analog Input Module, ±10 Vdc Differential Measurement Input

Wago 750-479 2-Channel Analog Input Module, ±10 Vdc Differential Measurement Input

WAGO 750-479 RTD temperature input module with four channels supporting Pt100 and Pt1000 sensors for WAGO 750 Series distributed I/O automation systems.

SKU: 750-479Alt SKU: 750479MPN: 750-479
Price
List Price £294.72 ex VAT
Your Price (ex VAT) Save 10%
£265.25 10% OFF
You save £29.47 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £265.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£265.25

Why Choose the WAGO 750-479 RTD Temperature Input Module?

The WAGO 750-479 is a reliable 4-channel RTD temperature input module designed for use with the WAGO 750 Series distributed I/O system. It allows PLCs and industrial automation controllers to measure temperature signals from resistance temperature detectors and convert them into digital values for monitoring, diagnostics and industrial process control.

The module supports commonly used Pt100 and Pt1000 RTD sensors, enabling precise temperature measurement across manufacturing systems, process plants and building automation installations. Integrated signal conditioning ensures accurate measurement and stable performance across distributed automation architectures.

When combined with WAGO fieldbus couplers and programmable controllers, the 750-479 enables scalable automation systems for industrial temperature monitoring and process instrumentation.

Key Advantages

  • Reliable 4-channel RTD temperature measurement.
  • Supports widely used Pt100 and Pt1000 temperature sensors.
  • High-resolution signal conversion for precise monitoring.
  • Compact module designed for WAGO 750 Series distributed I/O systems.
  • Seamless integration with WAGO fieldbus couplers and controllers.
  • Ideal for industrial temperature monitoring and automation applications.

Key Features

  • 4 RTD input channels.
  • Compatible with Pt100 and Pt1000 sensors.
  • Supports 2-wire and 3-wire RTD connections.
  • High-resolution analogue-to-digital conversion.
  • Status LEDs for diagnostics and operation indication.
  • CAGE CLAMP® spring terminals for secure wiring.
  • Compatible with WAGO 750 Series fieldbus couplers and controllers.

Industrial Temperature Monitoring

Resistance temperature detectors such as Pt100 and Pt1000 sensors are widely used across industrial automation systems due to their high measurement accuracy and long-term stability. These sensors are commonly applied in manufacturing machinery, industrial equipment and environmental monitoring systems.

Modules such as the WAGO 750-479 convert RTD signals into digital process values for PLCs and automation controllers, enabling precise monitoring and control across distributed industrial automation networks.

Typical Applications

  • Industrial temperature monitoring using Pt100 and Pt1000 sensors.
  • Machine and equipment temperature protection.
  • Manufacturing process instrumentation.
  • Energy systems and utilities monitoring.
  • Building automation and HVAC control systems.

Technical Specifications

Tick the specs you need, then view products that match.

Signal / Input Range ±10 V
Product Series WAGO I/O System 750
Device Type Analogue I/O Module
Signal Type / Function Analogue, Temperature (RTD/TC)
Number of I/O 4
IP Rating IP20
Series WAGO 750 Series I/O System
Module type RTD temperature input module
Number of inputs 4
Sensor compatibility Pt100, Pt1000
Connection type 2-wire and 3-wire RTD
Resolution 16-bit typical
Conversion time approx. 10 ms
System supply 5 V DC via data contacts
Connection technology WAGO CAGE CLAMP® terminals
Mounting DIN rail (EN 60715)
Operating temperature approx. 0 °C to +55 °C
Protection rating IP20
Module width approx. 12 mm
HS Code 85389099
Country of Manufacture Germany

Frequently Asked Questions

What does the WAGO 750-479 module do?

The module measures temperature signals from RTD sensors and converts them into digital values for PLC and automation systems.

How many temperature inputs does the module provide?

The module provides four independent RTD input channels.

Which temperature sensors are supported?

The module supports common Pt100 and Pt1000 RTD temperature sensors.

Which automation systems is the module compatible with?

The module is designed for the WAGO 750 Series distributed I/O system and operates with WAGO fieldbus couplers and programmable controllers.

How is the module installed?

The module mounts on a standard DIN rail and connects to adjacent WAGO I/O modules through the system backplane.

Trusted by Automation Engineers

WAGO 750 Series I/O modules are trusted worldwide by automation engineers and system integrators to build reliable distributed control systems across industrial automation environments.