Wago 750-478 2Ai, 0-10 Vdc Se

Wago 750-478 2Ai, 0-10 Vdc Se

WAGO 750-478 RTD temperature input module with eight channels supporting Pt100 and Pt1000 sensors for WAGO 750 Series distributed I/O automation systems.

SKU: 750-478Alt SKU: 750478MPN: 750-478
Price
List Price £243.33 ex VAT
Your Price (ex VAT) Save 10%
£219.00 10% OFF
You save £24.33 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £219.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£219.00

Why Choose the WAGO 750-478 RTD Temperature Input Module?

The WAGO 750-478 is a high-performance 8-channel RTD temperature input module designed for integration within the WAGO 750 Series distributed I/O system. It enables PLCs and industrial controllers to capture temperature signals from resistance temperature detectors and convert them into digital values for monitoring, diagnostics and process control.

The module supports widely used Pt100 and Pt1000 RTD sensors, delivering stable and precise temperature measurement across industrial automation systems. Integrated signal conditioning ensures reliable sensor acquisition and accurate temperature monitoring across distributed control architectures.

When combined with WAGO fieldbus couplers and programmable controllers, the 750-478 enables scalable temperature monitoring systems used in manufacturing equipment, process industries, energy infrastructure and building automation installations.

Key Advantages

  • Reliable 8-channel RTD temperature measurement.
  • Supports widely used Pt100 and Pt1000 sensors.
  • High-resolution conversion for precise temperature monitoring.
  • Compact design for WAGO 750 Series distributed I/O systems.
  • Seamless integration with WAGO fieldbus couplers and controllers.
  • Ideal for industrial temperature monitoring and instrumentation.

Key Features

  • 8 RTD input channels.
  • Compatible with Pt100 and Pt1000 temperature sensors.
  • Supports 2-wire and 3-wire RTD connections.
  • High-resolution analogue-to-digital conversion.
  • Status LEDs for diagnostics and operation indication.
  • CAGE CLAMP® spring terminals for secure wiring.
  • Compatible with WAGO 750 Series fieldbus couplers and controllers.

Industrial Temperature Monitoring

Resistance temperature detectors such as Pt100 and Pt1000 sensors are widely used across industrial automation systems because they provide highly accurate and stable temperature measurements across a wide operating range. These sensors are commonly used in manufacturing equipment, energy systems and environmental monitoring applications.

Modules such as the WAGO 750-478 convert RTD signals into digital process values for PLCs and automation controllers, enabling precise monitoring and control across distributed industrial automation architectures.

Typical Applications

  • Industrial temperature monitoring using Pt100 and Pt1000 sensors.
  • Machine and equipment temperature protection.
  • Manufacturing process instrumentation.
  • Energy systems and utilities monitoring.
  • Building automation and HVAC control systems.

Technical Specifications

Tick the specs you need, then view products that match.

Signal / Input Range 0–10 V
Product Series WAGO I/O System 750
Device Type Analogue I/O Module
Signal Type / Function Analogue, Temperature (RTD/TC)
Number of I/O 2
IP Rating IP20
Series WAGO 750 Series I/O System
Module type RTD temperature input module
Number of inputs 8
Sensor compatibility Pt100, Pt1000
Connection type 2-wire and 3-wire RTD
Resolution 16-bit typical
Conversion time approx. 10 ms
System supply 5 V DC via data contacts
Connection technology WAGO CAGE CLAMP® terminals
Mounting DIN rail (EN 60715)
Operating temperature approx. 0 °C to +55 °C
Protection rating IP20
Module width approx. 24 mm
HS Code 85389099
Country of Manufacture Germany

Frequently Asked Questions

What does the WAGO 750-478 module do?

The module measures temperature signals from RTD sensors and converts them into digital values for PLC and automation systems.

How many temperature inputs does the module provide?

The module provides eight independent RTD input channels.

Which temperature sensors are supported?

The module supports common Pt100 and Pt1000 RTD temperature sensors.

Which automation systems is the module compatible with?

The module is designed for the WAGO 750 Series distributed I/O system and operates with WAGO fieldbus couplers and programmable controllers.

How is the module installed?

The module mounts on a standard DIN rail and connects to adjacent WAGO I/O modules through the system backplane.

Trusted by Automation Engineers

WAGO 750 Series I/O modules are trusted worldwide by automation engineers and system integrators to build reliable distributed control systems across industrial automation environments.