Wago 750-377/025-000 FC Profinet, G3 T Eco Adv

Wago 750-377/025-000 FC Profinet, G3 T Eco Adv

WAGO 750-377/025-000 PROFINET IO fieldbus coupler with integrated 2-port Ethernet switch for connecting WAGO I/O System 750/753 modules to PROFINET industrial automation networks.

SKU: 750-377/025-000Alt SKU: 750377025000MPN: 750-377/025-000
Price
List Price £408.71 ex VAT
Your Price (ex VAT) Save 10%
£367.84 10% OFF
You save £40.87 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £367.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£367.84

Why Choose the WAGO 750-377/025-000 PROFINET IO Fieldbus Coupler?

The WAGO 750-377/025-000 is a 3rd-generation PROFINET IO fieldbus coupler designed for the modular WAGO I/O System 750/753. It connects distributed I/O modules to PROFINET industrial Ethernet networks, enabling real-time communication between field devices and PLC controllers in modern automation systems. :contentReference

During system start-up, the coupler automatically detects all installed digital, analogue and complex modules and generates a local process image. Digital signals are transferred bit-by-bit while analogue and complex data is transmitted word-by-word, allowing efficient communication with the PROFINET controller. :contentReference

The integrated two-port Ethernet switch enables line topology wiring without additional switches or hubs. This simplifies network design and allows distributed automation systems to expand easily across industrial installations. :contentReference

Key Advantages

  • Reliable PROFINET IO real-time industrial Ethernet communication.
  • Automatic detection and configuration of connected I/O modules.
  • Integrated two-port Ethernet switch for simple line topology.
  • Supports mixed installations of digital, analogue and complex modules.
  • Scalable architecture supporting up to 64 I/O modules per node.
  • Extended temperature version for demanding industrial environments.

Key Features

  • PROFINET IO fieldbus coupler for WAGO I/O System 750/753.
  • 10/100 Mbit/s Ethernet communication.
  • Integrated 2 × RJ-45 Ethernet interfaces with internal switch.
  • Automatic creation of a local process image of connected modules.
  • Device naming via DCP protocol or DIP switch.
  • Supports diagnostics and network topology detection.
  • DIN rail mounting for industrial control cabinets.

PROFINET Industrial Network Integration

PROFINET is widely used in industrial automation systems to connect PLC controllers, distributed I/O modules and industrial devices through Ethernet infrastructure. The WAGO 750-377/025-000 allows sensors and actuators connected to WAGO I/O modules to communicate with automation controllers using deterministic real-time PROFINET communication. :contentReference

Within the WAGO I/O architecture, signals from connected modules are automatically mapped into the Ethernet process image. This allows automation engineers to implement scalable distributed control systems across manufacturing, energy and process industries. :contentReference

Typical Applications

  • Distributed PLC I/O systems using PROFINET networks.
  • Industrial machine automation.
  • Factory automation and production lines.
  • Process monitoring and control systems.
  • Integration of sensors, actuators and analogue devices.

Technical Specifications

Tick the specs you need, then view products that match.

Supported Protocols PROFINET
Product Series WAGO I/O System 750
Device Type Communication / Function Module
Coil / Supply Voltage 24 V DC
Communication PROFINET
Voltage 24 V
IP Rating IP20
Series WAGO I/O System 750 / 753
Device type PROFINET IO fieldbus coupler
Communication protocol PROFINET IO
Ethernet speed 10 / 100 Mbit/s
Transmission method 100Base-TX
Network connection 2 × RJ-45 Ethernet
Transmission medium Twisted pair S-UTP Cat.5
Maximum segment length 100 m
Maximum modules per node 64
Process image up to 256 bytes input / 256 bytes output
Supply voltage 24 V DC (−25% to +30%)
Mounting DIN rail (EN 60715)
Operating temperature −20 °C to +60 °C
Ingress protection IP20
HS Code 85176200
Country of Manufacture Germany

Frequently Asked Questions

What does the WAGO 750-377/025-000 coupler do?

It connects WAGO I/O System 750/753 modules to a PROFINET IO network so PLC systems can communicate with distributed field devices.

How many I/O modules can be connected?

The coupler supports up to 64 I/O modules within a single distributed node.

Why are two Ethernet ports included?

The integrated switch allows devices to be connected in line topology without additional network switches.

What types of signals can be processed?

The coupler supports digital, analogue and complex modules with data transferred bit-by-bit or word-by-word depending on module type.

Where is the coupler installed?

The coupler is mounted at the start of a WAGO I/O node on a DIN rail within PLC control cabinets or distributed automation systems.

Trusted by Automation Engineers

WAGO PROFINET fieldbus couplers are widely used by automation engineers and system integrators to connect distributed I/O modules to industrial Ethernet control networks.