The WAGO 750-8208/025-001 is a versatile PFC200 programmable logic controller (PLC) designed for industrial automation, distributed I/O control and remote telemetry applications. Combining powerful processing capabilities with multiple industrial communication interfaces, this controller provides a flexible solution for machine control, process automation and infrastructure monitoring.
Featuring two 10/100 Mbit/s Ethernet ports, RS-232/RS-485 serial communication, CAN/CANopen connectivity and a PROFIBUS DP Master interface, the WAGO 750-8208/025-001 enables integration with a wide range of industrial equipment. Its dedicated telecontrol capabilities support communication protocols including IEC 60870-5-101/-103/-104, IEC 61850 and DNP3, making it particularly suitable for energy infrastructure and remote monitoring systems.
Powered by a 600 MHz ARM Cortex-A8 processor running real-time Linux, the controller provides 256 MB RAM, 256 MB internal flash memory and dedicated application memory. With a nominal 24 V DC supply, modular WAGO I/O expansion and an extended operating temperature range of −20 to +60 °C, it delivers reliable programmable control in demanding industrial environments.
The WAGO 750-8208/025-001 PFC200 controller is designed for automation applications that require communication across several industrial networks. Its combination of Ethernet, serial, CANopen and PROFIBUS DP Master interfaces allows engineers to connect compatible field devices and automation systems without relying on a separate controller for each communication technology.
The controller's dual Ethernet interfaces incorporate an integrated switch, allowing line topology networking with compatible industrial equipment. This can simplify installation and reduce the requirement for external Ethernet switches. Support for Modbus TCP/UDP and common network services enables integration with supervisory systems, industrial HMIs and remote monitoring platforms.
For existing fieldbus installations, the PROFIBUS DP Master interface enables communication with compatible PROFIBUS slave devices, while CAN/CANopen provides additional connectivity for distributed industrial equipment. RS-232 and RS-485 interfaces support communication with suitable serial devices, including equipment using Modbus RTU.
A distinguishing feature of the 750-8208/025-001 is its integrated telecontrol protocol support. The controller supports IEC 60870-5-101/-103/-104, IEC 61850-related communication and DNP3, enabling integration into compatible remote telemetry and supervisory control architectures.
These protocols are particularly relevant to electrical infrastructure, renewable energy installations, utility monitoring and geographically distributed industrial assets. The controller can collect information from connected WAGO I/O modules, execute local control logic and communicate operating data to higher-level systems.
Its ARM Cortex-A8 processor, real-time Linux operating system and IEC 61131-3 programming capabilities support local automation functions alongside industrial communication tasks. The integrated web server and WebVisu functionality provide additional options for device configuration, status monitoring and visualisation.
The extended −20 to +60 °C operating temperature range makes the controller suitable for appropriately protected installations exposed to wider temperature variations. Its modular design supports digital, analogue and specialist I/O modules from the compatible WAGO I/O System 750/753 range, subject to system configuration and power requirements.
| Number of HW-interfaces other | 2 |
|---|---|
| System accessory | Yes |
| Additional program memory possible | Yes |
| Supporting protocol for other bus systems | Yes |
| Number of HW-interfaces industrial Ethernet | 2 |
| Number of HW-interfaces RS-232 | 1 |
| Number of HW-interfaces RS-485 | 1 |
| SIL according to IEC 61508 | None |
| Supporting protocol for PROFIBUS | Yes |
| Supporting protocol for CAN | Yes |
| Supporting protocol for Modbus | Yes |
| Supply voltage DC | 24 – 24 V |
| Suitable for rail mounting | Yes |
| Voltage type (supply voltage) | DC |
| Model | Compact |
| Supporting protocol for EtherNet/IP | Yes |
| Memory size | 16384 kByte |
| Type of memory | RAM |
| Explosion safety category for gas | ATEX gas-ex-protection, Cat. 3G |
| Explosion safety category for dust | ATEX dust-ex-protection, Cat. 3D |
| Height | 100 mm |
| Performance level according to EN ISO 13849-1 | None |
| Width | 112 mm |
| Depth | 100 mm |
| Manufacturer | WAGO |
| Product series | PFC200 / WAGO I/O System 750/753 |
| Product type | Programmable logic controller / fieldbus controller |
| Controller version | Extended temperature with telecontrol technology |
| Processor | ARM Cortex-A8 |
| Processor clock speed | 600 MHz |
| Operating system | Real-time Linux with RT-Preempt patch |
| Main memory (RAM) | 256 MB |
| Internal flash memory | 256 MB |
| Programme memory | 16 MB |
| Data memory | 64 MB |
| Non-volatile hardware memory | 128 KB |
| Non-volatile software memory | 128 KB |
| Memory card | SD/SDHC, up to 32 GB |
| Ethernet interfaces | 2 × RJ45 |
| Ethernet transmission speed | 10/100 Mbit/s |
| Ethernet cable type | Shielded twisted pair, Cat. 5 |
| Maximum Ethernet segment length | 100 m |
| Ethernet topology | Line topology via integrated switch |
| Serial interfaces | RS-232 and RS-485 |
| CAN interface | CAN/CANopen |
| PROFIBUS interface | PROFIBUS DP Master |
| Modbus communication | Modbus TCP, Modbus UDP and Modbus RTU |
| Additional communication | MQTT |
| Telecontrol protocols | IEC 60870-5-101/-103/-104, IEC 61400-25, IEC 61850-7, DNP3 |
| Ethernet services | DHCP, DNS, NTP, FTP, FTPS, SNMP, HTTP, HTTPS, SSH |
| Visualisation | WebVisu |
| Programming standard | IEC 61131-3 |
| Programming software | WAGO-I/O-PRO V2.3 (CODESYS V2.3) |
| Programming languages | IL, LD, FBD, CFC, ST, SFC |
| Configuration | WAGO-I/O-CHECK and web-based management |
| Maximum I/O modules without bus extension | 64 |
| Maximum I/O modules per node | 250 |
| Internal input process image | 1000 words maximum |
| Internal output process image | 1000 words maximum |
| Modbus input/output process image | 1000 words / 1000 words maximum |
| PROFIBUS input/output process image | 5000 bytes / 5000 bytes maximum |
| CAN input/output process image | 2000 words / 2000 words maximum |
| System supply voltage | 24 V DC (−25% to +30%) |
| Typical input current at nominal load | 670 mA at 24 V DC |
| Total system supply current | 1700 mA |
| Field supply voltage | 24 V DC (−25% to +30%) |
| Power jumper contact current capacity | 10 A |
| Electrical isolation | 500 V between system and field |
| System supply connection | 2 × CAGE CLAMP® |
| Field supply connection | 6 × CAGE CLAMP® |
| Supported conductor cross-section | 0.08–2.5 mm² |
| Conductor strip length | 8–9 mm |
| Operating temperature | −20 to +60 °C |
| Storage temperature | −40 to +85 °C |
| Relative humidity | Up to 95%, non-condensing |
| Mounting type | DIN-35 rail |
| Depth from upper edge of DIN rail | 64.7 mm |
| Weight | Approx. 263.7 g |
| Housing material | Polycarbonate / Polyamide 6.6 |
| Housing colour | Light grey |
| GTIN | 4055143624862 |
The WAGO 750-8208/025-001 is a PFC200 programmable logic controller used for industrial automation, distributed I/O control and remote telemetry. It combines Ethernet, RS-232/RS-485, CAN/CANopen and PROFIBUS DP Master communication with dedicated telecontrol protocol support.
The controller provides two 10/100 Mbit/s Ethernet ports with an integrated Ethernet switch. These ports support line topology networking and communication using protocols such as Modbus TCP/UDP.
Yes. The controller includes a PROFIBUS DP Master interface for communication with compatible PROFIBUS slave devices. This makes it suitable for industrial installations using PROFIBUS-based equipment.
The WAGO 750-8208/025-001 supports IEC 60870-5-101/-103/-104, IEC 61400-25, IEC 61850-7 and DNP3. These protocols are used in compatible utility automation, energy infrastructure and remote monitoring systems.
The controller features a 600 MHz ARM Cortex-A8 processor, 256 MB RAM, 256 MB internal flash memory, 16 MB programme memory and 64 MB data memory.
The controller supports IEC 61131-3 programming using WAGO-I/O-PRO V2.3, based on CODESYS V2.3. Supported languages include Ladder Diagram, Function Block Diagram, Structured Text, Instruction List and Sequential Function Chart.
The controller requires a nominal 24 V DC system supply and supports a nominal 24 V DC field supply. Both supplies have a specified voltage tolerance of −25% to +30%, subject to the manufacturer's installation requirements.
The WAGO 750-8208/025-001 is an extended-temperature controller rated for operation from −20 to +60 °C. Its specified storage temperature range is −40 to +85 °C.
The controller supports up to 64 compatible I/O modules without bus extension and up to 250 modules per node when suitable bus extension hardware is used. Actual configurations depend on compatibility, current consumption and system limitations.
Yes. The controller includes an SD/SDHC memory card slot supporting cards up to 32 GB. WAGO specifies that guaranteed memory card properties apply when using the designated compatible WAGO memory card.
Yes. The WAGO 750-8208/025-001 supports Modbus TCP and Modbus UDP over Ethernet, as well as Modbus RTU through its compatible serial communication interface.
Yes. Its extended operating temperature range, modular I/O capabilities and telecontrol protocols make it suitable for appropriately engineered remote infrastructure applications, including electrical monitoring, renewable energy systems and utility automation.
WAGO PFC200 controllers provide automation engineers, system integrators and infrastructure operators with flexible programmable control and industrial communication capabilities. The WAGO 750-8208/025-001 combines dual Ethernet networking, PROFIBUS DP Master, CANopen, serial communication, telecontrol protocols and extended-temperature operation to support reliable automation across machinery, process control and remote infrastructure applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.