1SDA101521R1 ABB XT7L M 1600 Ekip Touch Measuring LSIG 1600 A 3-Pole MCCB

1SDA101521R1 ABB XT7L M 1600 Ekip Touch Measuring LSIG 1600 A 3-Pole MCCB

ABB 1SDA101521R1 is a SACE Tmax XT7L M 1600 A three-pole fixed moulded case circuit breaker with front connections and an Ekip Touch Measuring LSIG electronic trip unit providing advanced LSIG protection and integrated electrical measurement.

SKU: 1SDA101521R1MPN: 1SDA101521R1
Price
List Price £10,528.37 ex VAT
Your Price (ex VAT) Save 25%
£7,896.28 25% OFF
You save £2,632.09 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,896.28
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,896.28

Why Choose the ABB XT7L M 1600 Ekip Touch Measuring LSIG Circuit Breaker?

The ABB XT7L M 1600 Ekip Touch Measuring LSIG, order code 1SDA101521R1, is a high-performance three-pole moulded case circuit breaker (MCCB) designed for demanding low-voltage power distribution applications. Part of the ABB SACE Tmax XT family, this configuration combines a 1600 A rated current with the advanced Ekip Touch Measuring LSIG solid-state electronic protection release.

The Ekip Touch Measuring LSIG trip unit provides long-time, short-time, instantaneous and earth-fault protection together with integrated electrical measurement functionality. This combination supports precise circuit protection, monitoring and protection coordination in sophisticated industrial, commercial and infrastructure power distribution systems.

The XT7L M configuration combines a three-pole design with fixed construction and front terminal connections. Its L performance level provides 120 kA short-circuit breaking performance, making this 1600 A breaker particularly suitable for switchboards and distribution systems with very high prospective fault currents.

Key Advantages

  • High-current 1600 A moulded case circuit breaker for demanding power distribution systems.
  • Ekip Touch Measuring LSIG combines advanced electronic protection with integrated electrical measurement functionality.
  • Provides long-time, short-time, instantaneous and earth-fault protection.
  • 120 kA L-level short-circuit breaking performance for installations with very high prospective fault currents.
  • Rated for low-voltage AC systems up to 690 V AC.
  • Fixed three-pole configuration with front terminals provides robust switchboard integration.

Key Features

  • ABB SACE Tmax XT7L M moulded case circuit breaker.
  • 1600 A rated uninterrupted current.
  • Three-pole configuration.
  • Ekip Touch Measuring LSIG solid-state electronic release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Earth-fault protection.
  • Integrated electrical measurement functionality.
  • 640–1600 A overload protection adjustment range.
  • 960–16000 A short-time short-circuit adjustment range.
  • 2400–24000 A instantaneous short-circuit adjustment range.
  • 120 kA L-level short-circuit performance.
  • Fixed execution with front terminal connections.
  • IP20 degree of protection.

Advanced Protection and Measurement for High-Fault-Level Distribution

The ABB XT7L M provides comprehensive protection for high-current electrical distribution circuits where precise fault protection and electrical measurement are required. Its Ekip Touch Measuring LSIG release combines long-time, short-time, instantaneous and earth-fault protection with integrated measurement functionality, supporting effective protection coordination and improved visibility of electrical system conditions.

Combining a 1600 A current rating with 120 kA L-level short-circuit performance, fixed construction and front terminal connections makes this XT7L configuration particularly suitable for demanding industrial and infrastructure switchboards where very high prospective fault currents require exceptional interruption capability.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main incomer and feeder protection in electrical switchboards.
  • Manufacturing and process facilities.
  • Commercial buildings and infrastructure installations.
  • High-current machinery and equipment feeders.
  • Distribution systems requiring LSIG protection and integrated electrical measurement.
  • Installations with very high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA101521R1
Product type Moulded case circuit breaker (MCCB)
Frame XT7
Performance level L
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 3
Trip unit Ekip Touch Measuring LSIG
Release type Solid-state electronic release
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Measurement functionality Integrated electrical measurement
Overload protection adjustment range 640–1600 A
Short-time short-circuit adjustment range 960–16000 A
Instantaneous short-circuit adjustment range 2400–24000 A
Rated voltage 690 V AC
Short-circuit breaking performance 120 kA
Mounting / version Fixed
Terminal position Front
Degree of protection IP20
Power dissipation 94 W
Optional motor operator Yes
Standard EN/IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA101521R1?

The ABB 1SDA101521R1 is a SACE Tmax XT7L M three-pole fixed moulded case circuit breaker rated at 1600 A and equipped with an Ekip Touch Measuring LSIG solid-state electronic protection release.

What protection functions does the Ekip Touch Measuring LSIG provide?

The Ekip Touch Measuring LSIG release provides long-time, short-time, instantaneous and earth-fault protection together with integrated electrical measurement functionality.

What is the rated current of the ABB XT7L M 1SDA101521R1?

The circuit breaker has a rated current and rated uninterrupted current of 1600 A, making it suitable for demanding high-current low-voltage distribution applications.

What is the short-circuit performance of the ABB XT7L M 1600?

The XT7L M is an L performance-level breaker with 120 kA short-circuit breaking performance, making it suitable for electrical installations with very high prospective fault currents.

What protection adjustment ranges are available on the ABB 1SDA101521R1?

The electronic release provides an overload adjustment range of 640–1600 A, a short-time short-circuit adjustment range of 960–16000 A and an instantaneous short-circuit adjustment range of 2400–24000 A.

How many poles does the ABB 1SDA101521R1 have?

The ABB 1SDA101521R1 is a three-pole circuit breaker intended for three-phase low-voltage electrical distribution systems.

Is the ABB XT7L M 1SDA101521R1 fixed or withdrawable?

This model is a fixed circuit breaker with its main circuit connections positioned at the front.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are used across industrial, commercial and infrastructure power systems where advanced electronic protection, integrated electrical measurement, exceptional short-circuit performance and dependable switching are required.