1SFL617001R7111 af580-30-11-71 315kw/580 amps 250-500v 50/60hz dc ABB Contactor

SKU
AF580-30-11-71
Email for pricing and availability

ABB 1SFL617001R7111

Dimensions
Product Net Width: 210.0 mm
Product Net Depth: 242.0 mm
Product Net Height: 283.0 mm
Product Net Weight: 15.000 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 800 A
Rated Operational Current AC-1 (Ie):
(690 V) 55 °C 700 A
(690 V) 40 °C 800 A
(1000 V) 40 °C 800 A
(1000 V) 55 °C 700 A
(690 V) 70 °C 580 A
(1000 V) 70 °C 580 A
Rated Operational Current AC-3 (Ie):
(1000 V) 55 °C 250 A
(690 V) 55 °C 500 A
(415 V) 55 °C 580 A
(220 / 230 / 240 V) 55 °C 580 A
(440 V) 55 °C 580 A
(380 / 400 V) 55 °C 580 A
(500 V) 55 °C 580 A
Rated Operational Power AC-3 (Pe):
(220 / 230 / 240 V) 160 kW
(380 / 400 V) 315 kW
(415 V) 355 kW
(440 V) 355 kW
(500 V) 400 kW
(690 V) 500 kW
(1000 V) 355 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 1000 A
Rated Short-time Withstand Current (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 6000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 5000 A
Maximum Electrical Switching Frequency:
AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 60 cycles per hour
Rated Operational Current DC-1 (Ie):
(850 V) 3 Poles in Series, 40 °C 800 A
(600 V) 3 Poles in Series, 40 °C 800 A
(110 V) 1-Pole, 40 °C 800 A
(110 V) 2 Poles in Series, 40 °C 800 A
(220 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-3 (Ie):
(850 V) 3 Poles in Series, 40 °C 800 A
(600 V) 3 Poles in Series, 40 °C 800 A
(110 V) 1-Pole, 40 °C 800 A
(110 V) 2 Poles in Series, 40 °C 800 A
(220 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-5 (Ie):
(850 V) 3 Poles in Series, 40 °C 800 A
(600 V) 3 Poles in Series, 40 °C 800 A
(110 V) 1-Pole, 40 °C 800 A
(110 V) 2 Poles in Series, 40 °C 800 A
(220 V) 3 Poles in Series, 40 °C 800 A
Rated Insulation Voltage (Ui):
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 3 million
Maximum Mechanical Switching Frequency: 300 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
Rated Control Circuit Voltage (Uc):
60 Hz 250 … 500 V
50 Hz 250 … 500 V
DC Operation 250 … 500 V
Coil Consumption:
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 985 V·A
Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 910 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 985 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Operate Time:
Between Coil Energization and NO Contact Closing 50 ... 120 ms
Between Coil De-energization and NO Contact Opening 53 ... 73 ms
Between Coil De-energization and NC Contact Closing 50 ... 70 ms
Between Coil Energization and NC Contact Opening 45 ... 115 ms
Connecting Capacity Main Circuit:
Rigid Al-Cable 3x185 mm²
Bar 52 mm
Rigid Cu-Cable 300 mm²
Connecting Capacity Auxiliary Circuit:
Solid 2x1…4 mm²
Flexible with Insulated Ferrule 2x0.75…2.5 mm²
Stranded 1x1…4 mm²
Flexible 2x0.75…2.5 mm²
Flexible with Ferrule 2x0.75…2.5 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type: Main Circuit: Bars

More Information
Manufacturer ABB
kW Rating 315KW
Inbuilt Aux 1 N/O, 1 N/C
Manufacturer Part Number AF580-30-11-71
Product Lead Time Please contact us for a delivery time
Links Click here for link to ABB website info (opens in new tab)
Write Your Own Review
You're reviewing:1SFL617001R7111 af580-30-11-71 315kw/580 amps 250-500v 50/60hz dc ABB Contactor

ABB AF Contactor Range

ABB contactor range can be used to control power circuits up to a level of 690 V AC and 220 V DC. The main benefit of ABB's range of AF products are that only a few coils are needed for different control voltages used in many applications without having to change the coil.

These four coil voltages run from between 24...500 V 50/60 Hz or 20...500 V DC. These are AC/DC dual rated which cover a range of amperages rather than set specifications. ABB's AF contactors have built in surge protection and do not require any other surge suppressors.

Accessories are available in the form of front and side mounted auxiliary contact blocks plus being designed as a 1 stack 3 pole block type contactor they can have a one main auxiliary contact. Replacement parts are available as well as other accessories.

You can click on this link to view more ABB information

Latest News

Why choose the Rittal VX25 range for your operations?

Why choose the Rittal VX25 range for your operations?

March 26, 2024 Read full
4 key avenues to help increase efficiency in your operations

4 key avenues to help increase efficiency in your operations

March 21, 2024 Read full
4 common challenges with factory automation (and their solutions)

4 common challenges with factory automation (and their solutions)

February 27, 2024 Read full
Here’s what you need to know about surge protection

Here’s what you need to know about surge protection

February 23, 2024 Read full